background image

24V

GND

UL ALARM 12V

ALARM RET

RESET

GND

GATE

TAMPER

MAG

LOCK

OPEN

RIGHT

OPEN

LEFT

MAGLOCK

DELAY

PRIMARY

GATE

SAFETY

CENTER

EXIT

OPEN

MAX

GATE SPEED

STOP

CLOSE

ANTI

TAILGATE

CLOSE TIMER

POSITION

RECORDER

ID

PLUG

AUTOMATIC OPEN/CLOSE CONTROLS

BATTERY

BACK-UP MODE

MATRIX 1

PHOTOCELL

EDGE 1

EDGE 2

ID PLUG

ERROR

OPEN

COM

CLOSE

Tamper NO

COM

GND

Tamper IN

OFF

OFF

ON

EXIT

PARTIAL

OPEN

OBD PORT

BLACK BOX

MOTOR MOTION

CENTER

REVERSE SENSITIVITY

MOTOR OVERLOAD

NO LIMIT SWITCH /

CLAMP SLIPPING

MIN

MAX

12VDC

GND

24VDC

GND

MAX

MIN

OFF

SAFETY

LEAVE

OPEN

LEAVE

CLOSED

MADE in USA

OPEN
1 TIME

2Sec

1.5Sec

COM

NC

BATTERY

IN USE

POWER

GATE

STATUS

MOTOR

ON-LINE

LIMIT

SWITCH

ON-LINE

(+)

GND

(-)

PRIMARY

GATE

(+)

GND

(-)

SEC

GATE

 

UL

ENTRAP

PHOTOCELL

GND

STRIKE

GND

KEYP

AD / RDR

GND

FIRE DEPT

GND

MAX OPEN

GND

RADIO SIG.

RADIO GND

OPEN

STOP

CLOSE

COM

GA

TE DISABLE

E

T

T

ER

ER

R

R

R

R

R

R

R

Press Together

Gate Tamper
LEDs

gate tamper feature

Many different safety devices can be wired to the 

GATE TAMPER

. After device is wired to relay, it 

MUST

 be 

ARMED

 to function.

Security

Camera

MOTOR

ON-LINE

LIMIT

SWITCH

ON-LINE

24V

GND

UL ALARM 12V

ALARM RET

RESET

GND

GATE

TAMPER

MAG

LOCK

OPEN

RIGHT

OPEN

LEFT

MAGLOCK

DELAY

PRIMARY

GATE

SAFETY

CENTER

EXIT

OPEN

MAX

GATE SPEED

STOP

CLOSE

ANTI

TAILGATE

CLOSE TIMER

POSITION

RECORDER

ID

PLUG

AUTOMATIC OPEN/CLOSE CONTROLS

BATTERY

BACK-UP MODE

MATRIX 1

PHOTOCELL

EDGE 1

EDGE 2

ID PLUG

ERROR

OPEN

COM

CLOSE

Tamper NO

COM
GND

Tamper IN

OFF

OFF

ON

EXIT

PARTIAL

OPEN

OBD PORT

BLACK BOX

MOTOR MOTION

CENTER

REVERSE SENSITIVITY

MOTOR OVERLOAD

NO LIMIT SWITCH /

CLAMP SLIPPING

MIN

MAX

12VDC

GND

24VDC

GND

MAX

MIN

OFF

SAFETY

LEAVE

OPEN

LEAVE

CLOSED

MADE in USA

OPEN
1 TIME

2Sec

1.5Sec

COM

NC

BATTERY

IN USE

POWER

GATE

STATUS

(+)

GND

(-)

PRIMARY

GATE

(+)

GND

(-)

SEC

GATE

ENTRAP

PHOTOCELL

GND

STRIKE

GND

KEYP

AD / RDR

GND

FIRE DEPT

GND

MAX OPEN

GND

RADIO SIG.

RADIO GND

OPEN

STOP

CLOSE

COM

GA

TE DISABLE

ID

PLUG

PARTIAL

OPEN

CLOSE TIMER

MAX

PHOTOCELL

OFF

SAFETY

CENTER

OFF

ON

EXIT

GATE

TA

Tamper NO

Wiring Gate Tamper

GATE

TAMPER

Tamper NO

COM

GND

Tamper IN

The 

GATE TAMPER

 can be used for various functions 

such as turning a warning light, siren or camera on 
when the gate is tampered with (Vandalized Gate).
The gate operator defines a “Vandalized Gate” as 

UNAUTHORIZED

 movement of the gate. This can 

occur if the chain is dropped and gate is manually 
moved from the 

closed position 

or the gate is forced 

open from the 

closed position without authorization.

TAMPER NO/Com Relay:

 Connect a warning light, siren, camera or 

an existing alarm system to relay. 

TAMPER IN/GND Input:

 Connect a sensor device to input. When 

Tamper In/GND gets triggered, device that is wired to Tamper relay 
(NO/Com) will activate. 

Arm Gate Tamper (Turn ON)

Siren

Warning

Light

Motion
Sensor

Power

Power

Existing

Building

Alarm

System

The 

GATE TAMPER

 is factory set to 

OFF 

(Unarmed). It 

MUST

 be turned 

ON

 (Armed) or safety device connected to the 

GATE TAMPER 

relay will 

NOT

 activate.

 Press and 

HOLD

 the 

STOP

 button while simultaneously pressing 

 the 

POSITION RECORDER

 button. Hold 

BOTH

 buttons down until 

  Gate Tamper LEDs light up then turn OFF and a beep is heard. 

Gate Tamper

 is now 

ARMED (ON)

.

 NOTE:

 

DO NOT

 press the 

POSITION RECORDER

 button before 

 the 

STOP

 button or Gate Tamper will 

NOT

 Arm.

 To 

UNARM (Turn OFF) Gate Tamper 

repeat above step.

When 

GATE TAMPER

 is triggered, the 

OPERATOR ALARM

 and 

GATE TAMPER

 

relay will activate. The operator will shut 
down all operating functions.
The alarm reset button 

MUST

 be pressed to 

turn 

OFF

 the alarm and reset the operator.

If 

GATE TAMPER

 is armed and relay is connected to 

an existing building alarm system, then they will get a 
triggering of their alarm system and should be 
notified of the situation.

Alarm Reset Button

12

UL 325 2016 Standard-MAX Quick Install Rev 8

Содержание MAX 1500

Страница 1: ...l Guide for MAX 1500 MAX 2200 Slide Gate Operators www max us com 4009963 Residential Commercial Brushless DC Slide Gate Operators Made in USA CONFORMS TO UL STD 325 UL CLASS I II III IV CERTIFIED TO...

Страница 2: ...el Gate 1500 lbs Uphill Gate 5 Max Opening Time Selectable speed control MAX 12 inch per second Cycles per Hour AC Power Continuous Battery Back Up Cycles Batteries fully charged MAX 1500 approximatel...

Страница 3: ...apment protection CLOSING photocell and or sensing edge when not using Gate Link wireless transmitter In ground loop wires Conduit Guidelines and Suggestions 8 625 12 75 Conduit Area Input Power Condu...

Страница 4: ...perator is NOT parallel to gate Chain is NOT parallel to gate DO NOT mount chain bracket too high on gate NO NO YES YES YES YES Drive Gear NOTE The chain should sag no more than one 1 inch per 10 feet...

Страница 5: ...TIC OPEN CLO SE CONTR OLS BATTERY BACK UP MO DE MATRIX 1 PHOTOCELL EDGE 1 EDGE 2 ID PLUG ERRO R OPEN COM CLOSE Tamp er NO COM GN D Tamp er IN OFF OFF ON EXI T PARTIAL OPEN OBD PORT BLACK BOX MO TO R M...

Страница 6: ...earth or a grounding rod Dual Gate Operators NOTE Secondary operator will automatically be set to the opposite opening direction as the primary gate operator W ARNIN G W ARNIN G connect chass is to g...

Страница 7: ...ear reducer BEFORE cycling operator Breather Pin CAUTION REMOVE BEFORE OPERATION Limit Sensor Activator Limit Sensor Activator BLACK Limit Sensor Plug Plug PhotoCell Edge UL Entrap 1 2 Limit SW ON LIN...

Страница 8: ...d le a rn m o d e b e e p in g s to p s In p u ts a re n o w M O N IT O R E D 2 3 2 3 O P E N S T O P C LO S E MO TO R MO TIO N M C 2 0 0 S lid e EDGE 1 N C CLOSING Direction ONLY GND C Reflector GND...

Страница 9: ...ns when using wireless option If a self supporting post is being used then sensing edges need to be installed on EACH side of the post to protect against entrapment in the OPENING and CLOSING directio...

Страница 10: ...ate An input command press remote button or exit loop is needed BEFORE the gate will reset and close again When the gate encounters an obstruction during the OPEN cycle it will reverse approximately 6...

Страница 11: ...DR GND FIRE DEPT GND MAX OPEN GND RADIO SIG RADIO GND OPEN STOP CLOSE COM GATE DISABLE loops loop detectors 10 In Ground Loops Connections Safety Loops Wired in series Safety Loop Safety Loop Exit Loo...

Страница 12: ...ELL GND STRIKE GND KEYPAD RDR GND FIRE DEPT GND MAX OPEN GND RADIO SIG RADIO GND OPEN STOP CLOSE COM GATE DISABLE 12 VDC OR 24 VDC Radio Power 250 mA Max 4 Wire Radio 3 Wire Radio Card Reader Separate...

Страница 13: ...back of the Gate Shut Off switch after servicing the operator to prevent the switch from accidentally being turned ON during normal operation Plug the wire back in and turn ON the switch only while se...

Страница 14: ...GND STRIKE GND KEYPAD RDR GND FIRE DEPT GND MAX OPEN GND RADIO SIG RADIO GND OPEN STOP CLOSE COM GATE DISABLE ID PLUG PARTIAL OPEN CLOSE TIMER MAX PHOTOCELL OFF SAFETY CENTER OFF ON EXIT GATE TA Tamp...

Страница 15: ...ING GATE TAMPER If an existing alarm system Building alarm system is connected to the GATE TAMPER relay see previous page notify proper authorities BEFORE dropping the chain IMPROPER Dropping of Chain...

Страница 16: ...RIX JOG JOG LEFT RIG HT Jog LT Jog RT GND Edge 1 Edge 2 Photo Cell ERD Motor OverLoad POWER MC 200 Motor Controller 1615 14 13 12 3 4 5 MAX LED ON Sensitivity Edge ERD MOTOR Power In ALARM BATTERY PAC...

Страница 17: ..._CIO Communica on Established Fri 07 11 2014 10 57 38 ENTRAP PRI_MC Photo Cell Deac vated Fri 07 11 2014 10 57 34 ENTRAP PRI_MC Photo Cell Ac vated Fri 07 11 2014 10 57 21 INFO Radio Input Deac vated...

Страница 18: ...rapment sensor wiring or missing jumper If BATTERY IN USE LED is ON and BATTERY BACK UP MODE switch Leave Open then battery may be too low and gate is kept OPEN If BATTERY IN USE LED is ON and BATTERY...

Страница 19: ...n MAX 1500 MAX 2200 MAX F18 MAX 1500 MAX 2200 MAX F18 Insert ID PLUG module that is tethered to chassis into ID PLUG connector of Matrix 1 Check if AC POWER ON OFF SWITCH is ON Check 24 V wiring from...

Страница 20: ...ly ignore the flashing Check if Gate Shut off switch is ON Turn it OFF If it is OFF cycle the switch ON then OFF Check if the chain is dropped If so gate is disabled for safety Re install chain and cy...

Страница 21: ...ed or malfunctioning Sensor might need to be re learned Jumper between EDGE 2 and GND is missing or broken jumper is required if a sensor is not present Sensor on EDGE 2 input photocell or edge may ha...

Страница 22: ...power ON OFF switch is ON If so check AC power BATTERY Plug not plugged in to BATTERY IN port on battery module see below Battery needs to be replaced if BATTERY TEST fails and REPLACE BATTERY LED is...

Страница 23: ...FT RIG HT Jog LT Jog RT GND Edge 1 Edge 2 Photo Cell ERD Motor Ove rLoad POWER MC 200 Motor Controlle r 1615 14 13 12 3 4 5 MAX LE D ON Sen sitiv ity Ed ge ERD M O T O R P o w e r In A L A R M B A T T...

Страница 24: ...jumper unused inputs Entrapment Protection Sensor Guidelines 1 CAUTION See installation instructions ATTENTION Voir la notice d installation Edge 2 Photo Cell MC 200 PWR 12V MUST be used ONLY power en...

Страница 25: ...e and or Photo Cell can be wired to ANY of the 3 Inputs MC 200 PWR 12V MUST be used to power MONITORED sensors UNUSED inputs MUST remain JUMPERED or fault will occur GN D 1 2 3 GN D 1 2 3 Inputs MUST...

Страница 26: ...i n g E d g e M o n i t o r e d P h o t o C e l l OR G N D J o g R T J o g L T Entrapment Pro tection Inputs M U S T j u m p e r u n u s e d i n p u t s Entrapment Pro tection Sensor Guidelines 1 C A...

Страница 27: ...25 UL 325 2016 Standard MAX Quick Install Rev 8...

Страница 28: ...n River Ave Fountain Valley Ca 92708 Tel 949 699 0220 4009963 Residential Commercial Brushless DC Slide Gate Operators Made in USA CONFORMS TO UL STD 325 UL CLASS I II III IV CERTIFIED TO CAN CSA STD...

Отзывы: