background image

AC

IN

FUSE

7 Am

p

POW

ER

On

Of

f

www

.Ma

x.U

S.c

om

MAX T

oro

id 15 

Am

p

Se

lect I

npu

Vo

lta

ge 

11

5V

AC

 or 

230V

AC

115V

MAX

Toroid Box

ac input power

3

GFCI Outlet

NOT

 provided

DANGER

HIGH VOLTAGE!

Additional

Gang Box

Choose either 

115V

 or 

230V

 setting on input 

AC power selector switch

.

Wire desired input AC power wire to power terminal. A additional single gang box is provided to 
install power outlets if desired. GFCI outlet type is recommended.

Additional single gang box 
provided. Wire GFCI outlet 
to the input AC wire 

BEFORE

 connecting to 

operator power terminal if 
power outlets are desired.

LEDs should light up on operator.
Battery power 

automatically

 turns 

ON

.

Turn Power
ON

DO NOT

CYCLE

OPERATOR!

AC

IN

FU

SE

7 A

mp

PO

W

ER

On

Off

ww

w.

Ma

x.US

.co

m

MA

Tor

oid

 15 

Am

p

Sel

ec

t In

put

 

Vo

ltage 

11

5V

AC

 or 

23

0V

AC

115

V

dis

connec

t

power 

be

fo

re

ser

vic

in

g un

it

W

ARN

IN

G

W

AR

NI

NG

HIGH

H

IG

H

VO

LT

AG

E

VO

LT

AG

E

!

AT

TENT

IO

N!

AT

TE

NT

IO

N!

HI

G

H

H

IG

H

VOL

TAG

E

VO

LT

AG

E

!

de

'bra

nc

he

av

ant

 

l'e

nt

re

tien

L

I

M

I
T

S
E
N
S
O
R

ON

/O

FF

Ba

tte

ry

E

F

1/2

Re

pla

ce

Ba

ttery

TEST
Ba

tte

ry

PWR IN

Erro

r

Battery

 M

odu

le

Phot

oCe

ll E

dge

  UL

Entra

p

1

2

Limi

t SW

ON

-LINE

MA

TR

IX

JOG

JOG

LE

FT

RI

GH

T

Jog L

T

Jog R

T

GND

Edge 1

Edge 2

Photo

Cell

ER

D

    Mot

or

Ov

erL

oad

POW

ER

MC

-200

Mo

tor 

Con

tro

ller

1615 14

13

12

3

4

5

MAX

LE

D O

N

Se

nsi

tivi

ty

Ed

ge

ER

D

MOT

OR

Power

 In

PW

R 2

4V 

-  

GN

-  

RS-

485 

(-) 

-  

RS-

485 

(+

) -

  

MAT

RIX

BO

ARD

ALA

RM

BAT

TER

Y

PAC

K

LIM

IT

SW

ITCH

MOT

OR 

INP

UTS

2

4V

GN

D

UL AL

ARM

 12V

ALAR

M RE

T

RESE

T

GND

GAT

E

TAM

PER

MA

G

LOCK

OP

EN

RIGH

T

OP

EN

LEFT

MAG

LOCK

DELA

Y

PRIM

ARY

GAT

E

SAF

ETY

CEN

TER

EXIT

OPEN

MAX

GAT

E SPE

ED

STO

P

CLO

SE

AN

TI

TAIL

GATE

CLO

SE T

IME

R

POSI

TION

RECO

RDE

R

ID

PLU

G

AUT

OM

ATI

C OP

EN

/CLOSE

 CONT

ROL

S

BAT

TERY

BACK-

UP M

ODE

MA

TRIX

 1

PH

OTOCEL

L

EDG

E 1

EDG

E 2

ID PL

UG

ERROR

OPEN

COM

CLOSE

Tam

per N

O

CO

M

GND

Tam

per IN

OFF

OFF

ON

EXIT

PART

IAL

OPEN

OBD 

POR

T

BLAC

K BOX

MO

TOR 

MO

TIO

N

CENT

ER

REVE

RSE S

ENSITI

VITY

MOT

OR O

VER

LOAD

NO

 LIM

IT S

WITC

H /

CLAMP 

SLIPP

ING

MIN

MAX

12VD

C

GND

24VD

C

GND

MAX

MIN

OFF

SAFET

Y

LEAV

E

OPEN

LEAV

E

CLO

SED

MA

DE in

 USA

OP

EN

1 TI

ME

2Sec

1.5S

ec

CO

M

NC

BATT

ERY

IN U

SE

PO

WER

GATE

STATU

S

MOTO

R

ON-LIN

E

LIMIT

SW

ITCH

ON-L

INE

(+

)

GN

D

(-)

PRIM

ARY

GATE

(+)

GN

D

(-)

SEC

GAT

E

 

UL

ENT

RAP

PHOTOCEL

L

GND

ST

RIK

E

GN

D

KE

Y

PA

D

 / RD

R

GND

F

IRE 

D

EPT

GN

D

M

AX OPEN

GN

D

RADIO SIG.

RADIO GN

D

OPEN

STO

P

CLOS

E

CO

M

GA

TE DISABL

E

Turn ALL Power OFF

1  

Turn OFF 

POWER Switch 

on 

MAX Toroid Box.

  Battery power will 

remain ON

.

 

WAIT

 for 15 seconds.

3  Press and HOLD 

(approx. 5 seconds)

 the 

RED ON/OFF BATTERY

 button until

  MAX BC-7 LEDs turn 

ON

,

  then release button. LEDs will 
 turn 

OFF

. (Up to 30 sec.)

IMPORTANT:

 This procedure 

must be followed whenever 

ALL

 power must be turned 

OFF

 on operator.

1

3

Turn Power ON

Chassis (Green)

Neutral (White)

Line (Black)

Chassis (Green)

Neutral (White)

Line (Black)

Single Phase 115VAC Only

115VAC

Single Phase 230VAC Only

230VAC

Input AC Power Options

Set to 115V

115V

230V

Set to 230V

Power Terminal

IMPORTANT:

 Make sure there are 

NO

 exposed bare 

wires at the power terminal connection.

115 

OR

 230VAC

Power Wire

CAUTION:

  

Make sure circuit 

breaker is OFF from incoming 
AC input wire BEFORE wiring!

di

sconn

ec

t

power 

before

ser

vicing 

unit

WARNIN

G

W

AR

NI

NG

HIGH

H

IG

H

VO

LT

AG

E

VO

LT

AG

E

!

Power

Terminal

AC Power
Gang Box

Input AC Power

Selector Switch

AC

IN

FUSE

7 Amp

POW

ER

On

Of

f

www

.Max.US.c

om

MAX 

To

ro

id 15 Amp

Selec

t Input 

Vo

ltage 

11

5V

AC or 

230V

AC

11

5V

MAX

Toroid Box

7 Amp Fuse

CAUTION:

  If input AC power selector 

switch is set for 

115V

 but input power 

is actually 

230 V

, 7 Amp Fuse will blow.

AC

Powe

r

Bo

x

Additional

Bo
x

3

UL 325 2016 Standard-MAX Quick Install Rev 8

Содержание MAX 1500

Страница 1: ...l Guide for MAX 1500 MAX 2200 Slide Gate Operators www max us com 4009963 Residential Commercial Brushless DC Slide Gate Operators Made in USA CONFORMS TO UL STD 325 UL CLASS I II III IV CERTIFIED TO...

Страница 2: ...el Gate 1500 lbs Uphill Gate 5 Max Opening Time Selectable speed control MAX 12 inch per second Cycles per Hour AC Power Continuous Battery Back Up Cycles Batteries fully charged MAX 1500 approximatel...

Страница 3: ...apment protection CLOSING photocell and or sensing edge when not using Gate Link wireless transmitter In ground loop wires Conduit Guidelines and Suggestions 8 625 12 75 Conduit Area Input Power Condu...

Страница 4: ...perator is NOT parallel to gate Chain is NOT parallel to gate DO NOT mount chain bracket too high on gate NO NO YES YES YES YES Drive Gear NOTE The chain should sag no more than one 1 inch per 10 feet...

Страница 5: ...TIC OPEN CLO SE CONTR OLS BATTERY BACK UP MO DE MATRIX 1 PHOTOCELL EDGE 1 EDGE 2 ID PLUG ERRO R OPEN COM CLOSE Tamp er NO COM GN D Tamp er IN OFF OFF ON EXI T PARTIAL OPEN OBD PORT BLACK BOX MO TO R M...

Страница 6: ...earth or a grounding rod Dual Gate Operators NOTE Secondary operator will automatically be set to the opposite opening direction as the primary gate operator W ARNIN G W ARNIN G connect chass is to g...

Страница 7: ...ear reducer BEFORE cycling operator Breather Pin CAUTION REMOVE BEFORE OPERATION Limit Sensor Activator Limit Sensor Activator BLACK Limit Sensor Plug Plug PhotoCell Edge UL Entrap 1 2 Limit SW ON LIN...

Страница 8: ...d le a rn m o d e b e e p in g s to p s In p u ts a re n o w M O N IT O R E D 2 3 2 3 O P E N S T O P C LO S E MO TO R MO TIO N M C 2 0 0 S lid e EDGE 1 N C CLOSING Direction ONLY GND C Reflector GND...

Страница 9: ...ns when using wireless option If a self supporting post is being used then sensing edges need to be installed on EACH side of the post to protect against entrapment in the OPENING and CLOSING directio...

Страница 10: ...ate An input command press remote button or exit loop is needed BEFORE the gate will reset and close again When the gate encounters an obstruction during the OPEN cycle it will reverse approximately 6...

Страница 11: ...DR GND FIRE DEPT GND MAX OPEN GND RADIO SIG RADIO GND OPEN STOP CLOSE COM GATE DISABLE loops loop detectors 10 In Ground Loops Connections Safety Loops Wired in series Safety Loop Safety Loop Exit Loo...

Страница 12: ...ELL GND STRIKE GND KEYPAD RDR GND FIRE DEPT GND MAX OPEN GND RADIO SIG RADIO GND OPEN STOP CLOSE COM GATE DISABLE 12 VDC OR 24 VDC Radio Power 250 mA Max 4 Wire Radio 3 Wire Radio Card Reader Separate...

Страница 13: ...back of the Gate Shut Off switch after servicing the operator to prevent the switch from accidentally being turned ON during normal operation Plug the wire back in and turn ON the switch only while se...

Страница 14: ...GND STRIKE GND KEYPAD RDR GND FIRE DEPT GND MAX OPEN GND RADIO SIG RADIO GND OPEN STOP CLOSE COM GATE DISABLE ID PLUG PARTIAL OPEN CLOSE TIMER MAX PHOTOCELL OFF SAFETY CENTER OFF ON EXIT GATE TA Tamp...

Страница 15: ...ING GATE TAMPER If an existing alarm system Building alarm system is connected to the GATE TAMPER relay see previous page notify proper authorities BEFORE dropping the chain IMPROPER Dropping of Chain...

Страница 16: ...RIX JOG JOG LEFT RIG HT Jog LT Jog RT GND Edge 1 Edge 2 Photo Cell ERD Motor OverLoad POWER MC 200 Motor Controller 1615 14 13 12 3 4 5 MAX LED ON Sensitivity Edge ERD MOTOR Power In ALARM BATTERY PAC...

Страница 17: ..._CIO Communica on Established Fri 07 11 2014 10 57 38 ENTRAP PRI_MC Photo Cell Deac vated Fri 07 11 2014 10 57 34 ENTRAP PRI_MC Photo Cell Ac vated Fri 07 11 2014 10 57 21 INFO Radio Input Deac vated...

Страница 18: ...rapment sensor wiring or missing jumper If BATTERY IN USE LED is ON and BATTERY BACK UP MODE switch Leave Open then battery may be too low and gate is kept OPEN If BATTERY IN USE LED is ON and BATTERY...

Страница 19: ...n MAX 1500 MAX 2200 MAX F18 MAX 1500 MAX 2200 MAX F18 Insert ID PLUG module that is tethered to chassis into ID PLUG connector of Matrix 1 Check if AC POWER ON OFF SWITCH is ON Check 24 V wiring from...

Страница 20: ...ly ignore the flashing Check if Gate Shut off switch is ON Turn it OFF If it is OFF cycle the switch ON then OFF Check if the chain is dropped If so gate is disabled for safety Re install chain and cy...

Страница 21: ...ed or malfunctioning Sensor might need to be re learned Jumper between EDGE 2 and GND is missing or broken jumper is required if a sensor is not present Sensor on EDGE 2 input photocell or edge may ha...

Страница 22: ...power ON OFF switch is ON If so check AC power BATTERY Plug not plugged in to BATTERY IN port on battery module see below Battery needs to be replaced if BATTERY TEST fails and REPLACE BATTERY LED is...

Страница 23: ...FT RIG HT Jog LT Jog RT GND Edge 1 Edge 2 Photo Cell ERD Motor Ove rLoad POWER MC 200 Motor Controlle r 1615 14 13 12 3 4 5 MAX LE D ON Sen sitiv ity Ed ge ERD M O T O R P o w e r In A L A R M B A T T...

Страница 24: ...jumper unused inputs Entrapment Protection Sensor Guidelines 1 CAUTION See installation instructions ATTENTION Voir la notice d installation Edge 2 Photo Cell MC 200 PWR 12V MUST be used ONLY power en...

Страница 25: ...e and or Photo Cell can be wired to ANY of the 3 Inputs MC 200 PWR 12V MUST be used to power MONITORED sensors UNUSED inputs MUST remain JUMPERED or fault will occur GN D 1 2 3 GN D 1 2 3 Inputs MUST...

Страница 26: ...i n g E d g e M o n i t o r e d P h o t o C e l l OR G N D J o g R T J o g L T Entrapment Pro tection Inputs M U S T j u m p e r u n u s e d i n p u t s Entrapment Pro tection Sensor Guidelines 1 C A...

Страница 27: ...25 UL 325 2016 Standard MAX Quick Install Rev 8...

Страница 28: ...n River Ave Fountain Valley Ca 92708 Tel 949 699 0220 4009963 Residential Commercial Brushless DC Slide Gate Operators Made in USA CONFORMS TO UL STD 325 UL CLASS I II III IV CERTIFIED TO CAN CSA STD...

Отзывы: