www.maxcessintl.com
Tidland Raptor AP Chuck
MI 660290 1 P
Page 16 of 28
6" AIR POWERED LUG CHUCK
Installation
1. Before mounting, ensure the o-ring is installed on the chuck.
If it is not installed, see PARTS LIST on page 15 and
order a replacement.
Caution! Do not mount chuck without the o-ring in place.
2. Align the chuck register with the spindle register.
3. Holding chuck in place on the spindle, rotate the chuck until bolt
holes are aligned.
4. Insert 1/2-13NC socket head bolts (6 places).
5. Before loading roll/core, apply operating air pressure to the chuck
to ensure that chuck lugs expand and collapse properly. If they do not, refer to
TROUBLESHOOTING on page 26.
6. Install roll/core, making sure that the core fully covers the lugs.
Chuck is ready for use.
To install the Raptor Series Adapter, see pages 24-25.
Operation
Rotary Air Supply
Operate the chuck at 80-120 psi (5.5-8.3 bar) for optimal performance.
Side Valve Air Supply
A Custom Mounting Flange with a side valve is required for operation. Contact a Tidland
Customer Service Representative for additional information or if your chuck arrives without
the flange (1-800-426-1000).
To Inflate (Actuate) Chuck
1. Ensure that cores fully cover the chuck lugs.
2. Use the Tidland Inflation Tool.
3. Push the air nozzle firmly into the valve
located in the mounting flange.
4. Inflate the chuck until the air supply pressure
gauge indicates a minimum of 80 psi (5.5 bar).
Deflating the Chuck
1. Stop chuck rotation.
2. Rotary Air: Shut off air supply to the valve.
Side Valve: Using the Tidland Air Release Tool, push in the quick release side air
valve, allowing the air to escape through the hole in the center of the button.
3. Remove the chuck from the roll/core.
WARNING
Use a hoist and safe handling procedures during installation.
Chuck weight is 70 lbs.
It is equipped with a 3/8-16 threaded hole to
accommodate a screw eye for lifting.
BODY HAZARD. Core must fully cover lugs during operation.
Keep the operating pressure above 80 psi (5.5 bar) to help ensure safety and optimal
performance. Do not exceed the maximum air pressure of 120 psi (8.3 bar).