12.0
COMMUNICATION (OPTIONAL)
www.maxcessintl.com
MAGPOWR Spyder-Plus-S1 Tension Control
MI 850A351 1 C
Page 64 of 68
Starting
Modbus
Register
Parameter Name
Parameter
Format
Parameter
Type
Used with
Control Types
Read /
Write
Range
0x7B
Digital Input Active State
BYTE
Data
LC, DTND,
DTD, DS, OPT
Read /
Write
0 = Active Low
1 = Active High
0x7C
Security State
BYTE
None
LC, DTND,
DTD, DS, OPT
Read
Only
0 = Not Locked
1 = Locked
0x7D
Security Code
UINT16
None
LC, DTND,
DTD, DS, OPT
Write
Only
{ 0 - 9999 }
0x7E
Numeric Display Rate
FLOAT
Data
LC, DTND,
DTD, DS, OPT
Read /
Write
{ 0.0 - 60.0 } seconds
0x80
Bar Graph Display Rate
FLOAT
Data
LC, DTND,
DTD, DS, OPT
Read /
Write
{ 0.0 - 60.0 } seconds
0x82
Position Setpoint 0% Calibration
Point
FLOAT
Cal
DTND, DTD,
DS
Read /
Write
{ 0 - 4095 }
0x84
Position Setpoint 100% Calibration
Point
FLOAT
Cal
DTND, DTD,
DS
Read /
Write
{ 0 - 4095 }
0x86
Dancer 0% Calibration Point
FLOAT
Cal
DTND, DTD,
DS
Read /
Write
{ 0 - 4095 }
0x88
Dancer 100% Calibration Point
FLOAT
Cal
DTND, DTD,
DS
Read /
Write
{ 0 - 4095 }
0x8A
Tuning Type (Dancer Torque)
BYTE
Data
DTND
Read /
Write
0 = PD
1 = PID
0x8B
Tuning Type (Dancer Speed)
BYTE
Data
DS
Read /
Write
0 = P
1 = PI
0x8C
Proportional Gain (Dancer)
FLOAT
Data
DTND, DTD,
DS
Read /
Write
{ 0.0 - 999.0 }
0x8E
Integrator Time (Dancer)
FLOAT
Data
DTND, DTD,
DS
Read /
Write
{ 0.0 - 60.0 } seconds
0x90
Initial Screen (Load Cell)
BYTE
Data
LC
Read /
Write
0 = Operator Menu
1 = Tension
2 = Output Level
0x91
Initial Screen (Dancer)
BYTE
Data
DTND, DTD,
DS
Read /
Write
0 = Operator Menu
1 = Position
2 = Output Level
0x92
Use Taper?
BYTE
Data
LC, OPT
Read /
Write
0 = No
1 = Yes
0x93
System State Status
UINT16
None
LC, DTND,
DTD, DS, OPT
Read
Only
0 = Hold
1 = Start
2 = Run
3 = Stop
4 = E-Stop
5 = Manual
0x94
Tension On/Off Status
UINT16
None
LC, DTND,
DTD, DS, OPT
Read
Only
0 = Tension Off
1 = Tension On
0x95
Tension Setpoint
FLOAT
None
LC
Read
Only
{ 0.0 - 99999.0 } lb.
0x97
Actual Tension
FLOAT
None
LC, DTND,
DTD
Read
Only
{ 0.0 - 99999.0 } lb.
0x99
Actual Output
FLOAT
None
LC, DTND,
DTD, DS, OPT
Read
Only
{ 0.0 - 100.0 } %
0x9B
Actual Diameter
FLOAT
None
LC, DTD, DS,
OPT
Read
Only
{ 0.0 - 999.0 } in.
0x9D
Position Setpoint
FLOAT
None
DTND, DTD,
DS
Read
Only
{ 0.0 - 100.0 } %
0x9F
Actual Position
FLOAT
None
DTND, DTD,
DS
Read
Only
{ 0.0 - 100.0 } %
0xA1
Device Name
STRING
Data
LC, DTND,
DTD, DS, OPT
Read /
Write
31 Characters Maximum
0xB1
Program Version
UINT32
None
LC, DTND,
DTD, DS, OPT
Read
Only
920Axxx.yyy
xxx,yyy={0 - 999}
xxx = High Word
yyy = Low Word
0xB3
Modbus Address
UINT16
Data
LC, DTND,
DTD, DS, OPT
Read /
Write
{ 0 - 255 }