12.0
COMMUNICATION (OPTIONAL)
www.maxcessintl.com
MAGPOWR Spyder-Plus-S1 Tension Control
MI 850A351 1 C
Page 63 of 68
Starting
Modbus
Register
Parameter Name
Parameter
Format
Parameter
Type
Used with
Control Types
Read /
Write
Range
0x4C
Core Diameter
FLOAT
Data
LC, DTD, DS,
OPT
Read /
Write
{ 0.0 - 999.0 } in.
0x4E
Full Roll Diameter
FLOAT
Data
LC, DTD, OPT
Read /
Write
{ 0.0 - 999.0 } in.
0x50
Diameter Calibration Constant
FLOAT
Cal
LC, DTD, DS,
OPT
Read /
Write
{ 0.0 - 99999.0 }
0x52
Tension Units
BYTE
Data
LC, DTND,
DTD, DS
Read /
Write
0 = pound
1 = ounce
2 = Kilogram
3 = Newton
4 = gram
0x53
Distance Units
BYTE
Data
LC, DTD, DS,
OPT
Read /
Write
0 = inch
1 = feet
2 = millimeter
3 = centimeter
4 = meter
0x54
Proportional Gain (Load Cell)
FLOAT
Data
LC
Read /
Write
{ 0.0 - 999.0 }
0x56
Integrator Time (Load Cell)
FLOAT
Data
LC
Read /
Write
{ 0.0 - 60.0 } seconds
0x58
Derivative Time (Dancer)
FLOAT
Data
DTND, DTD
Read /
Write
{ 0.0 - 60.0 } seconds
0x5A
Error Limit
FLOAT
Data
LC, DTND,
DTD, DS
Read /
Write
{ 0.0 - 100.0 } %
0x5C
Start Time
FLOAT
Data
LC
Read /
Write
{ 0.0 - 60.0 } seconds
0x5E
Stop Time
FLOAT
Data
LC, DTND,
DTD, DS, OPT
Read /
Write
{ 0.0 - 60.0 } seconds
0x60
Stop Multiplier
FLOAT
Data
LC, DTND,
DTD, OPT
Read /
Write
{ 0.0 - 99.0 }
0x62
Hold Level
FLOAT
Data
LC, DTND,
DTD
Read /
Write
{ 0.0 - 100.0 } %
0x64
Torque Output 0% Calibration Point
(0-10V, 4-20mA)
FLOAT
Cal
LC, DTND,
DTD, DS, OPT
Read /
Write
{ 0.0 - 1.0 }
0x66
Torque Output 100% Calibration
Point
(0-10V, 4-20mA)
FLOAT
Cal
LC, DTND,
DTD, DS, OPT
Read /
Write
{ 0.0 - 1.0 }
0x68
Torque Output 0% Calibration Point
(-10V to +10V)
FLOAT
Cal
LC, DTND,
DTD, DS, OPT
Read /
Write
{ 0.0 - 1.0 }
0x6A
Torque Output 100% Calibration
Point
(-10V to +10V)
FLOAT
Cal
LC, DTND,
DTD, DS, OPT
Read /
Write
{ 0.0 - 1.0 }
0x6C
Tension Meter 100% Calibration
Point
FLOAT
Cal
LC, DTND,
DTD, DS, OPT
Read /
Write
{ 0 - 511 }
0x6E
Tension Setpoint 0% Calibration
Point
FLOAT
Cal
LC, OPT
Read /
Write
{ 0 - 4095 }
0x70
Tension Setpoint 100% Calibration
Point
FLOAT
Cal
LC, OPT
Read /
Write
{ 0 - 4095 }
0x72
Manual Setpoint 0% Calibration
Point
FLOAT
Cal
LC, OPT
Read /
Write
{ 0 - 4095 }
0x74
Manual Setpoint 100% Calibration
Point
FLOAT
Cal
LC, OPT
Read /
Write
{ 0 - 4095 }
0x76
Load Cell Positive Bias
UINT16
Cal
LC, DTND,
DTD, DS
Read /
Write
{ 0 - 511 }
0x77
Load Cell Negative Bias
UINT16
Cal
LC, DTND,
DTD, DS
Read /
Write
{ 0 - 511 }
0x78
Load Cell Gain Reference
UINT16
Cal
LC, DTND,
DTD, DS
Read /
Write
{ 0 - 511 }
0x79
Load Cell Offset
UINT16
Cal
LC, DTND,
DTD, DS
Read /
Write
{ 0 - 4095 }
0x7A
Applied Tension Binary
UINT16
Cal
LC, DTND,
DTD, DS
Read /
Write
{ 0 - 4095 }