11
SEQUENTIAL TRIP
Identified by
ORANGE TRIGGER.
CONTACT TOP
•
When replacing the contact top, make sure to
lock the trigger and remove the air hose.
•
Use contact top L if the screw does not tighten
(such as when fastening drywall boards to thin
steel or soft wooden base materials, etc.).
∗
The contact top L reduces the driving quantity, makes the re-
sult more stable by reducing the effects on the base material,
and reduces the occurrence of loose screws.
The contact top L is 3 mm longer than the standard contact top,
and reduces the driving quantity on base materials.
•
If there is no improvement even when using the
contact top L, set the CHANGEOVER LEVER to
“W” (wooden base).
DRIVING DEPTH ADJUSTMENT DIAL
•
ALWAYS disconnect air supply before Adjust-
ment dial.
1
With air pressure set, drive nails into a representative mate-
rial sample to determine if adjustment is necessary.
2
If adjustment is required, disconnect air supply.
3
Refer to the mark on the Adjust Spacer for direction to turn
the adjustment dial.
4
Reconnect air supply.
Contact top (orange)
Standard contact top
Contact top L (transparent)
Included contact top
WARNING
CAUTION
Adjust dial
Shallow
Deeper
WARNING
Deeper