background image

Useful New Functions

These are applicable to wide range of usages as various methods of use is possible by adding -LDe option. 

Output control as Next A to D are possible.

Function for Pulse & Ramp Sequence and Master Follow (-LDe Option)

Note :  Accuracy of the timer at sequence action ±0.5 %. Please take care usage at long running.

ta, tb, tc and toff can be set to 0.0 s, 1.0 s to 99.9 h, respectively 

tb

tc

toff

a

b

c

ta

t 1

t 2

0 V (output off)

Output

ON

Output

OFF

t1

a

c

b

ta

t2

tb

t3

tc

t4 toff

0 V

(output off)

Set voltage

    current

t1 and t2 can be set to 0 s to 999 s, respectively 

Range of 0 to 999 s for t1 to t4 and range of 0.0 s, 1.0 s to 99.9 h for ta to tc and 

toff can be set respectively. 

Master

Slave1

Slave2

Pulse
Sequence setting

Ramp setting

Pulse
Sequence setting

Sequential operation is possible by using voltage and current set on each 
memory a, b and c in combination with multi-set function. Not only 
continuous operation, but also it is possible to specify the times.
It is best fit to evaluation tests for products as various operations, like as 
repeat of a and b only or repeat of b, c and off only, are enabled by setting 
time of memory a, b, c and off to 0.0.

A. Pulse Sequence

It enables to make ramp action up to set voltage or current (or from the 
set voltage or current to 0 V or 0 A). It is useful to like to rise (reduce) 
voltage or current slowly.

* For ramp action, it is possible to select “both of set voltage and current”, 
 “only set voltage” or “only set current”.

B. Ramp

It is also possible to use pulse sequence combined with ramp action.
If multi-set function is combined with the too, it is able to make sequence 
action by using voltage or current set on memory a, b and c. Not only 
continuous operation, but also it is possible to specify the times.
It is useful in various aspects as it is possible to rise (reduce) voltage or 
current slowly up to 3 set value.

C. Pulse Se Ramp

D. Master Follow

Pulse sequence actions at master-slave and output signal to slave units
at ramp action are transmitted. By this function, it is possible to make 
slave units to output on different output condition from the master unit.

05

Содержание RKT Series

Страница 1: ...ent 5 to 100 A Max output power 400 W 800 W 1600 W 400 W model 800 W model 1600 W model Turbo Function is installed so that it can output widely in compact size DC Turbo Power Supplies www matsusada com NEW NEW Programmable DC Turbo Power Supplies RKT Series ...

Страница 2: ...l 4 digits indicator for voltage and current rotary encoder so that it is possible to set and read speedy and accurately and so on Also for 400 W models it have been enabled to set speedy by providing FINE switch so that it is possible to set the specified digits on the indicator at setting output Moreover they are applicable to various automatic measurement and production facility as LAN Ethernet...

Страница 3: ... Solar Battery and Fuel Battery Evaluation of Power Devise When you like to impress various voltage Evaluation of Inverter Applied to multiple systems as 100 V or 200 V system with One Unit Features Best fit to Research and Development by the Low Noise Switching System Free to Service Space with the Power Factor Correction Circuit and Worldwide Input System It realizes Wide Range Output by install...

Страница 4: ...Normal Lock that locks only output ON OFF Full Lock is for the case that you like to prevent securely any miss operation or Normal Lock is for the case that you like to prevent any miss operation but can easily stop in emergency It is the useful function to secure Safe you want It is possible to emergency stop with the power switch in every mode Normal Lock All switches are locked except the unloc...

Страница 5: ...ify the times It is best fit to evaluation tests for products as various operations like as repeat of a and b only or repeat of b c and off only are enabled by setting time of memory a b c and off to 0 0 A Pulse Sequence It enables to make ramp action up to set voltage or current or from the set voltage or current to 0 V or 0 A It is useful to like to rise reduce voltage or current slowly For ramp...

Страница 6: ...uel battery by making voltage depression from current loaded by setting internal resistance to 0 00 to 32 00 in CV Constant Voltage mode operation When noisy environment is presumed Gob optical interface is required See page 10 for detail A A CO M cable One piece 2 mL is included per a unit for 1600 W Model only for no interface option Please consult our sales staff if much more extension required...

Страница 7: ...Current Set Values of Output Volt Output Current Percent Mode 100 0 Volt Current mode Max Rated Value for Volt Current Setting of OVP OCP Percent Mode 100 0 Volt Current mode Max Protection Value to Overvoltage Overcurrent Setting for OVP OCP Percent Mode 100 0 Volt Current mode Max Protection Value to Overvoltage Overcurrent Minimum value for each model is the same with the minimum displayed digi...

Страница 8: ...els Ventilation Hole Digital Interface used for master slave too Change over Switch Sink Anti sink 1 2 3 4 5 6 1 2 3 4 5 6 1 7 8 2 9 10 3 4 5 6 7 8 9 10 11 12 13 14 15 7 8 9 10 11 11 12 13 16 17 14 12 13 14 15 400 W Model Front Rear 800 W Model 1600 W Model 6 FINE Switch only for 400 W Model change over set digit at setting output voltage and current 3 2 1 4 18 3 1 1 2 3 2 Input Terminal 3 400 W M...

Страница 9: ...6 60 2 36 60 Rear Side Rear Side Weight 3 kg approx Weight 6 kg approx Weight 6 kg approx Weight 14 kg approx 0 71 18 0 87 22 13 78 350 0 71 18 13 78 350 0 87 22 13 78 350 O I IN OUTPUT OFF OUT TB1 AC100 240V6 2A50 60Hz INPUT S S ON NSC 4 88 124 0 31 8 4 88 124 0 31 8 4 88 124 0 31 8 2 76 70 2xM6 OUTPUT A CC V CV IN OUT TB1 S S OFF NSC AC 100 240V 16A 50 60Hz ON GND OUTPUT INPUT N L 8 27 210 8 27 ...

Страница 10: ... perfect insulation is made by optical fiber it is able to forestall miss operation as transient phenomenon caused by surge dielectric thunder or foreign noise etc LGob LGob Fc5 LGob Fc10 LGob Fc20 LGob Fc40 Optical Interface board Optical cable 2 m Optical Interface board Optical cable 5 m Optical Interface board Optical cable 10 m Optical Interface board Optical cable 20 m Optical Interface boar...

Страница 11: ...rming up Ripple Stability Variations and Temp coefficient are applied F S x Catalogue Value and Linearity of output Linearity of monitor Linearity of indications are applied F S x value of 0 5 at the applied range of 10 to 100 of maximum rated output Preset value does not indicate exactly actual output state If require exact setting set voltage value by making actually output in no load For curren...

Страница 12: ...ntial or other damages resulting from a breach of the foregoing warranty This warranty excludes any and all other warranties not set forth herein express or implied including without limitation the implied warranties of merchantability or fitness for a particular purpose The Products are not designed and produced for such applications as requiring extremely high reliability and safety or involving...

Отзывы: