Options
AC Input Cable
250 V / 10 A
CABLE TYPE 3
(Applicable 400 W Models)
250 V / 10 A
CABLE TYPE 4
(Applicable 400 W Models)
Please suffix above optional codes on the tall of Model NO.
How to Order
[Example] RKT80-50(800W)-LDeGob(Mc0.5)Z
RKT650-5(800W)-LDeEt(Mc0.15)Z
RKT650-8(1600W)-LDeUs1 (alphabetical)
125 V / 15 A
CABLE TYPE 2
(Standard Attach. of 800 W Models)
Please consult our sales staff about AC cable for 1600 W Models.
*1 : These options can not be selected together.
*2 : If these options is selected for 1600 W model, standard digital interface and master-slave function are
not equipped. Please refer to the catalog of digital controller for power supplies “CO series” for the detail
of digital interface function.
*3 : -L(Mc0.5) or -L(Mc0.15) option cannnot be selected with -LGob, -LUs1 or -LEt option. (for 1600 W models)
*4 : Rack Mount Type is not covered.
1 piece (2 mL) is included to
-LGob optioned models.
Consult to our sales staff
if more extension is requied.
CO-opt cable
Various Adapter
(sold separately)
Total 14 CO-G32
can be hooked
with GPIB 1
Total 32 units can be
hooked with 1 CO-G32
CO-G32
CO-OPT2-25
CO-OPT2-9
CO-OPT4-25
Total 32 units can be
hooked with 1 CO-U32
Each CO-OPT can
connect up to 32 units.
CO-U32
Total 32 units can be
hooked with 1 CO-E32
CO-E32
h
u
b
h
u
b
B
B
B
B
Can be add
thru hub
Can be add
thru hub
Insulation control is made with optical communication.As perfect
insulation is made by optical fiber it is able to forestall miss operation
as transient phenomenon caused by surge, dielectric thunder or foreign
noise, etc.
-LGob
-LGob
(
Fc5
)
-LGob
(
Fc10
)
-LGob
(
Fc20
)
-LGob
(
Fc40
)
Optical Interface board + Optical cable 2 m
Optical Interface board + Optical cable 5 m
Optical Interface board + Optical cable 10 m
Optical Interface board + Optical cable 20 m
Optical Interface board + Optical cable 40 m
-LGob : Optical interface Board
*1 *2 *3
USB hub needs between PC
and RKT if control plural RKT.
-LUs1 : USB Interface Board
Digital control is enabled through USB.
Digital control is enabled thru LAN (Ethernet).
Length of CO-M cable is to be 0.5 m and 0.15 m, respectively.
(only either one is selectable.)
-LEt : LAN(Ethernet) Interface Board
-L(Mc0.5), -L(Mc0.15) : Change Communication Cable Length
*1
*2 *3
Handle for carriage is attached on the top board.
-LZ : Handle for carrying
*4
*1
*2 *3
Hub needs between PC and
RKT if control RKT thru Ethernet.
OS for Personal Computers : Microsoft Windows Xp / Vista / 7 / 8
Both of 32 bits and 64 bits are applicable
(Microsoft and Windows are registered trademark of Microsoft Corp. in USA and other.)
Please refer to page 5 for detail.
-LDe : Pulse and Ramp Sequence
h CO OPT
125 V / 10 A
CABLE TYPE 1
(Standard Attach. of 400 W Models)
When use them under following conditions, select -LGob always.
Noisy environment as in a factory. (Ex. A motor or a coil is used near to load or power supply)
Used in high voltage floating. (250 V and higher)
Our power supply and controller (PC or PLC) can not be installed within 2 m.
RS-232C
RS-485
LAN
Ethernet
)
USB
GPIB
10