Standard Functions

Remote Switch ON / OFF

Remote Control

Function of Variable Internal Resistance

Digital Interface

Master-slave Control

COM

FLT

OUTPUT

ON at OUTPUT status
ON at abnormal status
ON at CV or CC status

A

A

Master Unit

Slave

Up to 16 units

or

CV, CC

Imoni

V

Vmoni

V

Output

0 to MAX

0

 to 

10 Vdc

Output imp. 1 k

0

 to 

10 Vdc

Output

  

imp. 1 k

5 V

or

OVP, OCP

TB1

Switching Remote / Local

Output Control

Output Monitor

Output of Status

TTL

LOW

HIGH

Vout

-

Iout

R

Cont Volt

0 to MAX

0 to 10 Vdc
Input Imp. 500 k

0 to 10 k

Vout

-

Iout

Cont Volt.

0 to Max
X5 to 110 %

0 to 10 Vdc
Input Imp. 20 k

TB1

-S (common)

TB1

-S (common)

TB1

-S (common)

TB1

-S (common))

Mode

remote

local

External Relay

short
open

5 V

or

V

CE

-S (common)

Output

ON

OFF

Relay

Short
Open

Open Collector

V

CE

   

0.4 V

V

CE

   

2 V

Sink current 1 mA
Logic of OUTPUT can be made reverse.

ON for the status of OVP,

 

OCP, OTP, reverse sense connection and interlock (LD).  

Possible to switch 10 k

 to 0 k

 for Fail-Safe

CV

CC

One-control on local in parallel is enabled up to 16 units with 
master-slave operation

This is not a function for parallelly connected 
power supplies to give out average output
current.

Output is made ON / OFF with an external relay or open collector.

It is possible to simulate simply second battery, solar battery or 

fuel battery by making voltage depression from current loaded by 

setting internal resistance to 0.00 to 32.00 

 in CV (Constant Voltage) 

mode operation. 

When noisy environment is presumed, -Gob (optical interface) is required. 
See page 10. for detail.

A

A CO-M cable

One piece(2 mL) is included 
per a unit.(for 1600 W Model, 
only for no interface option.)
Please consult our sales staff, 
if much more extension 
required.

A

CO-M cable

One piece(2 m L) is included per 
a unit.(for 1600 W Model, only for 
no interface option.)
Please consult our sales staff, 
if much more extension required.

In addition to digital control with LAN (Ethernet), USB, RS-232C, 
RS-485 and GPIB, one control is enabled in master-slave operation.

Various Adapter

(sold separately)

Total 14 CO-G32m 
can be hooked with 
1 port  of GPIB.

Total 16 units can be hooked 
with one CO-G32m.

CO-G32m

D-sub plug-in phone jack

CO-MET2-25
CO-MET2-9
CO-MET4-25

Total 16 units can be hooked 
with one CO-E32m.

Each CO-MET can connect
up to 16 units.

CO-U32m

Total 16 units can be hooked 
with one CO-E32m.

CO-E32m

h
u
b

h
u
b

A

A

A

Can be add thru hub

Can be add thru hub

RS-232C

RS-485

LAN

(Ethernet)

USB

GPIB

It has to hook with each same model in 
the same series in master-slave. 
(at Slave Remote at Delayed Trigger.
 see page 4 ”Delayed Trigger Function”)

Each mode for Voltage, Current, 
OVP, OVP can be switched with 
relay or TTL signal.

COMMON is floating with the output of Open Collector for each COMMON.
Voltage Resistance 30 Vdc, Sink Current  5 mA

06

Содержание RKT Series

Страница 1: ...ent 5 to 100 A Max output power 400 W 800 W 1600 W 400 W model 800 W model 1600 W model Turbo Function is installed so that it can output widely in compact size DC Turbo Power Supplies www matsusada com NEW NEW Programmable DC Turbo Power Supplies RKT Series ...

Страница 2: ...l 4 digits indicator for voltage and current rotary encoder so that it is possible to set and read speedy and accurately and so on Also for 400 W models it have been enabled to set speedy by providing FINE switch so that it is possible to set the specified digits on the indicator at setting output Moreover they are applicable to various automatic measurement and production facility as LAN Ethernet...

Страница 3: ... Solar Battery and Fuel Battery Evaluation of Power Devise When you like to impress various voltage Evaluation of Inverter Applied to multiple systems as 100 V or 200 V system with One Unit Features Best fit to Research and Development by the Low Noise Switching System Free to Service Space with the Power Factor Correction Circuit and Worldwide Input System It realizes Wide Range Output by install...

Страница 4: ...Normal Lock that locks only output ON OFF Full Lock is for the case that you like to prevent securely any miss operation or Normal Lock is for the case that you like to prevent any miss operation but can easily stop in emergency It is the useful function to secure Safe you want It is possible to emergency stop with the power switch in every mode Normal Lock All switches are locked except the unloc...

Страница 5: ...ify the times It is best fit to evaluation tests for products as various operations like as repeat of a and b only or repeat of b c and off only are enabled by setting time of memory a b c and off to 0 0 A Pulse Sequence It enables to make ramp action up to set voltage or current or from the set voltage or current to 0 V or 0 A It is useful to like to rise reduce voltage or current slowly For ramp...

Страница 6: ...uel battery by making voltage depression from current loaded by setting internal resistance to 0 00 to 32 00 in CV Constant Voltage mode operation When noisy environment is presumed Gob optical interface is required See page 10 for detail A A CO M cable One piece 2 mL is included per a unit for 1600 W Model only for no interface option Please consult our sales staff if much more extension required...

Страница 7: ...Current Set Values of Output Volt Output Current Percent Mode 100 0 Volt Current mode Max Rated Value for Volt Current Setting of OVP OCP Percent Mode 100 0 Volt Current mode Max Protection Value to Overvoltage Overcurrent Setting for OVP OCP Percent Mode 100 0 Volt Current mode Max Protection Value to Overvoltage Overcurrent Minimum value for each model is the same with the minimum displayed digi...

Страница 8: ...els Ventilation Hole Digital Interface used for master slave too Change over Switch Sink Anti sink 1 2 3 4 5 6 1 2 3 4 5 6 1 7 8 2 9 10 3 4 5 6 7 8 9 10 11 12 13 14 15 7 8 9 10 11 11 12 13 16 17 14 12 13 14 15 400 W Model Front Rear 800 W Model 1600 W Model 6 FINE Switch only for 400 W Model change over set digit at setting output voltage and current 3 2 1 4 18 3 1 1 2 3 2 Input Terminal 3 400 W M...

Страница 9: ...6 60 2 36 60 Rear Side Rear Side Weight 3 kg approx Weight 6 kg approx Weight 6 kg approx Weight 14 kg approx 0 71 18 0 87 22 13 78 350 0 71 18 13 78 350 0 87 22 13 78 350 O I IN OUTPUT OFF OUT TB1 AC100 240V6 2A50 60Hz INPUT S S ON NSC 4 88 124 0 31 8 4 88 124 0 31 8 4 88 124 0 31 8 2 76 70 2xM6 OUTPUT A CC V CV IN OUT TB1 S S OFF NSC AC 100 240V 16A 50 60Hz ON GND OUTPUT INPUT N L 8 27 210 8 27 ...

Страница 10: ... perfect insulation is made by optical fiber it is able to forestall miss operation as transient phenomenon caused by surge dielectric thunder or foreign noise etc LGob LGob Fc5 LGob Fc10 LGob Fc20 LGob Fc40 Optical Interface board Optical cable 2 m Optical Interface board Optical cable 5 m Optical Interface board Optical cable 10 m Optical Interface board Optical cable 20 m Optical Interface boar...

Страница 11: ...rming up Ripple Stability Variations and Temp coefficient are applied F S x Catalogue Value and Linearity of output Linearity of monitor Linearity of indications are applied F S x value of 0 5 at the applied range of 10 to 100 of maximum rated output Preset value does not indicate exactly actual output state If require exact setting set voltage value by making actually output in no load For curren...

Страница 12: ...ntial or other damages resulting from a breach of the foregoing warranty This warranty excludes any and all other warranties not set forth herein express or implied including without limitation the implied warranties of merchantability or fitness for a particular purpose The Products are not designed and produced for such applications as requiring extremely high reliability and safety or involving...