Principal Functions

Memor

 a

Memory 

c

Memory 

b

OUTPUT ON

On the master unit

OUTPUT OFF

On the master unit

Total 16 units 

Master

Slave1

Slave2

Slave3

t1

t5

t2

t6

t3

t7

t4

t8

* t1 to T8 can be set in the range 0.0 s to 99.9 s.

Delayed Trigger Function

2 Modes for Lock

Switching function of Sink / Anti-Sink

Prevention of 
reverse current

Battery

Dual Tracking and Multi-Output

Dual Tracking 

Multi Output

Master 

OUTPUT ON
(On the master unit)

Master 

Remote
Slave 

Remote Slave
(output followed master) 

Master 

Remote

Slave 

Dual
Tracking 

Local
Slave 

+V

0

V

OUTPUT ON
(On the master unit)

Remote Slave
(output followed master) 

Local Slave
(output set in local) 

Master 

+V

1

+V

2

0

V

+

Function for Multi-setting

+

Sink Function

 is built in power supplies, it is safe as able to lower 

voltage quickly at cut-off output or even when lower voltage from 
high voltage setting point. And, when make continuously burn-in 
with short interval, it is possible to disconnect and change work 
quickly after cut-off operation of output. 
Conversely, when supply power to battery, condenser and so on 
which is capacious load, it decrease reverse current from the load 
to power supplies and avoids voltage depression by using 

Anti-Sink 

Function

 at cut-off output or when lower setting voltage.    

Note : It is impossible to stabilize by reverse current control. If the load is what reverse voltage 
becomes higher than rated voltage (induced load, regenerative motor, etc.), please protect 
the power supply by connecting dummy resister, reverse current protection diode and so on. 

3 values for voltage and current are memorized 
in addition to usual ones of preset.

  It is very 

useful for experiment to collect repeatedly data 
and inspection of products.

1

2

Long-push

Select memory
by 3 buttons.

LOCK

LOCK

3

Set Voltage
and Current

Full Lock 

LOCK

LOCK

LOCK

Either of 2 Modes can be selected and set, 
“Full Lock” that locks all operation from the 
front panel or “Normal Lock” that locks only 
output ON /

 

OFF.

“Full Lock” is for the case that you like to 
prevent securely any miss-operation, or 
“Normal Lock” is for the case that you like 
to prevent any miss-operation but can easily 
stop in emergency. It is the useful function to 
secure “Safe” you want.

(It is possible to emergency stop with the power 
 switch in every mode.)

Normal Lock

All switches are locked except the unlock-switch. 

It is useful for the purpose to prevent miss-stop 

at remote control or to prevent miss-operation 

completely.  

Knob to set output volt/current is locked. It is useful 

for the purpose to prevent to change output value 

by mistake at local control to make emergency stop 

easily. 

Dual tracking control, so that 

output of plus and minus 

are controlled at the same time

, is possible by 

connecting the power supply so as to be able to 
become plus and minus output at master-slave. 
Multi-output can be configured in combination with 
actions of local mode and of dual tracking. 
Plus and minus output voltage and optional output 
voltage set on a local slave are outputted in 
synchronizing with ON of the master unit.

* As for connection, please refer to 
 “examples for operation applied” on Page 11.

+

*1 : R4K-36 series, R4K-80 series, RK-80 series, RK series, TB series and REK series. Detail catalog for each 
      model is available. Please contact nearby sales office.
*2 : Can be connected up to 16 pcs.
*3 : Only for slave-local. In case of slave remote control, exact same model of power supply need to be used. Also, 
      in case of slave-local, each output voltage and current can be set  individually. In case of slave-remote, output 
      voltage and current can be set with one-control function which each slave unit follows the master unit setting.

In case -LUs1,-LEt or -LGob option is selected, only one unit of RKT series can be used.

Function to delay the OUTPUT ON / OFF time. It is possible to use in case single 
unit of RKT series is used, and also when connecting several Matsusada power 
supplies(*1) using master-slave connection terminal(*2) and output voltage / output 
current are set individually, delay trigger function can be used.(*3)

04

Содержание RKT Series

Страница 1: ...ent 5 to 100 A Max output power 400 W 800 W 1600 W 400 W model 800 W model 1600 W model Turbo Function is installed so that it can output widely in compact size DC Turbo Power Supplies www matsusada com NEW NEW Programmable DC Turbo Power Supplies RKT Series ...

Страница 2: ...l 4 digits indicator for voltage and current rotary encoder so that it is possible to set and read speedy and accurately and so on Also for 400 W models it have been enabled to set speedy by providing FINE switch so that it is possible to set the specified digits on the indicator at setting output Moreover they are applicable to various automatic measurement and production facility as LAN Ethernet...

Страница 3: ... Solar Battery and Fuel Battery Evaluation of Power Devise When you like to impress various voltage Evaluation of Inverter Applied to multiple systems as 100 V or 200 V system with One Unit Features Best fit to Research and Development by the Low Noise Switching System Free to Service Space with the Power Factor Correction Circuit and Worldwide Input System It realizes Wide Range Output by install...

Страница 4: ...Normal Lock that locks only output ON OFF Full Lock is for the case that you like to prevent securely any miss operation or Normal Lock is for the case that you like to prevent any miss operation but can easily stop in emergency It is the useful function to secure Safe you want It is possible to emergency stop with the power switch in every mode Normal Lock All switches are locked except the unloc...

Страница 5: ...ify the times It is best fit to evaluation tests for products as various operations like as repeat of a and b only or repeat of b c and off only are enabled by setting time of memory a b c and off to 0 0 A Pulse Sequence It enables to make ramp action up to set voltage or current or from the set voltage or current to 0 V or 0 A It is useful to like to rise reduce voltage or current slowly For ramp...

Страница 6: ...uel battery by making voltage depression from current loaded by setting internal resistance to 0 00 to 32 00 in CV Constant Voltage mode operation When noisy environment is presumed Gob optical interface is required See page 10 for detail A A CO M cable One piece 2 mL is included per a unit for 1600 W Model only for no interface option Please consult our sales staff if much more extension required...

Страница 7: ...Current Set Values of Output Volt Output Current Percent Mode 100 0 Volt Current mode Max Rated Value for Volt Current Setting of OVP OCP Percent Mode 100 0 Volt Current mode Max Protection Value to Overvoltage Overcurrent Setting for OVP OCP Percent Mode 100 0 Volt Current mode Max Protection Value to Overvoltage Overcurrent Minimum value for each model is the same with the minimum displayed digi...

Страница 8: ...els Ventilation Hole Digital Interface used for master slave too Change over Switch Sink Anti sink 1 2 3 4 5 6 1 2 3 4 5 6 1 7 8 2 9 10 3 4 5 6 7 8 9 10 11 12 13 14 15 7 8 9 10 11 11 12 13 16 17 14 12 13 14 15 400 W Model Front Rear 800 W Model 1600 W Model 6 FINE Switch only for 400 W Model change over set digit at setting output voltage and current 3 2 1 4 18 3 1 1 2 3 2 Input Terminal 3 400 W M...

Страница 9: ...6 60 2 36 60 Rear Side Rear Side Weight 3 kg approx Weight 6 kg approx Weight 6 kg approx Weight 14 kg approx 0 71 18 0 87 22 13 78 350 0 71 18 13 78 350 0 87 22 13 78 350 O I IN OUTPUT OFF OUT TB1 AC100 240V6 2A50 60Hz INPUT S S ON NSC 4 88 124 0 31 8 4 88 124 0 31 8 4 88 124 0 31 8 2 76 70 2xM6 OUTPUT A CC V CV IN OUT TB1 S S OFF NSC AC 100 240V 16A 50 60Hz ON GND OUTPUT INPUT N L 8 27 210 8 27 ...

Страница 10: ... perfect insulation is made by optical fiber it is able to forestall miss operation as transient phenomenon caused by surge dielectric thunder or foreign noise etc LGob LGob Fc5 LGob Fc10 LGob Fc20 LGob Fc40 Optical Interface board Optical cable 2 m Optical Interface board Optical cable 5 m Optical Interface board Optical cable 10 m Optical Interface board Optical cable 20 m Optical Interface boar...

Страница 11: ...rming up Ripple Stability Variations and Temp coefficient are applied F S x Catalogue Value and Linearity of output Linearity of monitor Linearity of indications are applied F S x value of 0 5 at the applied range of 10 to 100 of maximum rated output Preset value does not indicate exactly actual output state If require exact setting set voltage value by making actually output in no load For curren...

Страница 12: ...ntial or other damages resulting from a breach of the foregoing warranty This warranty excludes any and all other warranties not set forth herein express or implied including without limitation the implied warranties of merchantability or fitness for a particular purpose The Products are not designed and produced for such applications as requiring extremely high reliability and safety or involving...

Отзывы: