4-1
4 Advanced Operation
4
Advanced Operation
4-1 Introduction
Explanations on Remote Programming Operations.
With this feature such functions as external voltage control or external monitor is available.
By using GP-IB/IEEE488 or RS 232C adapter (option), operation via PC is also possible.
4-2 Function of TB1 interface connector
List 4-1 Function of TB1 interface connector
TB1
SIGNAL
PARAMETER
1
Remote Voltage Program In
0 to 10Vdc input = 0 to 100% rated output
2
Remote Current Program In
0 to 10Vdc input = 0 to 100% rated output
3
Output Current Monitor
0 to 10Vdc output = 0 to 100% rated output
4
Spare(out of use)
5
Common(GND of Power Supply)
For 1 , 2 , 3 , 14 , 15
6
Spare(out of use)
7
Door switch(
Interlock)
Short = HV ON
8
Remote reset(for Option LOc,)
Short = reset
9
Spare(out of use)
10
Spare(out of use)
11
Spare(out of use)
12
Spare(out of use)
13
Spare(out of use)
14
Reference voltage output
Ref10.24V,4mA MAX output
15
Output Voltage Monitor
0 to 10Vdc output = 0 to 100% rated output
16
Spare(out of use)
17
Common(GND of Power Supply)
For 7 , 8 , 19 , 20 , 21
18
Spare(out of use)
19
HV Status
HV ON = internally relay contact is shorted
20
Internal control/external control select
Short =External control Open =Internal control
21
Remote switch ON/OFF
Short = HV ON Open = HV OFF
22
Spare(out of use)
23
Spare(out of use)
24
Spare(out of use)
25
Current Control : EXT/INT select
Internal current control
1
13
14
25
S2
TB1
Fig 4-1 TB1 Connector,S2 Switch
20-17 short
25-2 short