4-6
4 Advanced Operation
4-8 Output current monitor, Output voltage monitor
4-8-1 Output current monitor (L1)
10V voltage is output at the maximum output current. The output impedance is 1kΩ.
The monitor output polarity is positive regardless of the high voltage output polarity.
4-8-2 Output voltage monitor (L2)
10V voltage is output at the maximum output voltage. The output impedance is 1kΩ.
The monitor output polarity is positive regardless of the high voltage output polarity.
4-9 HV status signal
When the OUTPUT ON/OFF switch is ON, the internally built-in relay contact is ON.
Caution When the contact is open, the voltage is 30Vdc MAX and
the permissible current is 100mA MAX.
TB1
14
15
16
17
18
19
1
2
3
4
5
6
VOLTAGE MONITOR AMP
Z out=1kΩ
Fig 4-7
Output current monitor, Output voltage monitor
V
1kΩ
0-10Vdc
V
0-10Vdc
1kΩ
10Ω,1/2W
Fig 4-8
HV status signal
16
17
18
19
20
3
4
5
6
7
TB1
!
CURRENT MONITOR AMP