1) To enter Engineering Mode, press & hold the INCLINE DOWN
and SPEED DOWN keys at the same time for 3-5 seconds until
Manager Mode appears on the display.
2) Press the INCLINE or SPEED keys until Engineering Mode
appears on the display (Figure A) and press ENTER.
3) To scroll between settings in the Engineering Mode, press the
INCLINE or SPEED keys.
4) Press ENTER to modify the settings once displayed.
5) Press any INCLINE or SPEED key to change the value of the
setting.
6) Press the PAUSE key to exit the setting without saving.
7) Once the setting is correct, press ENTER to save.
8) Press the EMERGENCY STOP to exit Engineering Mode..
6.1 USiNG eNGiNeeriNG mode
CUSTom SeTTiNG defaUlT miNimUm
maximUm
UNiT
deSCriPTioN
Disable Errors
OFF
OFF
ON
N/A
Off - Shows Class A-C errors. On - Shows Class C errors only.
Elevation Minimum
28
20
239
N/A
Controls the low incline parameter.
Elevation Maximum 230
20
239
N/A
Controls the high incline parameter.
Auto Calibration
N/A
N/A
N/A
N/A
This function is to calibrate the treadmill incline.
Speed Units
MILE
MILE
KILOMETER
DISTANCE Measurement unit used for calorie calculations, distance, and
speed.
Pause Time
5
MINUTES
5 SECONDS
10 MINUTES SECOND /
MINUTE
Controls the maximum time the treadmill can be paused during
a workout.
Serial Number
Serial Number input is available for both the Console and
Frame. Due to the limited LED characters, 2 layers are used to
enter the serial number. First Layer:
- PPPPP V
- PPPPP is the product name
- V is the version. If the version is A, just leave this blank.
Second Layer
- YY MM nnnnn.
- YY is the year (11, 12).
- MM is the month (e.g. 08, 09, 10).
- nnnnn is the actual serial number.
Use the UP / DOWN LEVEL keys to navigate the layers and
the number keys to input the serial number. The product name
is dependent on the Machine Type setting.
For example, the console is TM523 with ver. A and the
manufactured date is 2012.10 with 98765. The frame is TM523
with ver. A and the manufactured date is 2012.11 with 32345.
Their serial numbers are:
Console SN: TM523 1rst layer, 121098765 2nd layer.
Frame SN: TM523 1rst layer, 121132345 2nd layer.
Reset Defaults
N/A
N/A
N/A
N/A
Reset the default values to factory settings.
Club ID
N/A
N/A
N/A
N/A
This sets the club ID for clubs using Asset Management.
Audio Source
OFF
OFF
TV / PCTV /
REMOTE TV
N/A
Sets which outside TV will have audio through the console
audio ports.
AM System
RF RADIO
N/A
To select AM output device by WIFI or RF Radio.
Volume Control
OFF
A. INPUT DEFAULT :15
B. MAX DEFAULT :32
C. OUTPUT DEFAULT :13
Controls the default TV volume for entertainment wired through
the C-Safe port.
a. Input Default (DF : 15 / Range : 1 ~ 15)
b. Max Default (DF : 32 / Range : 1 ~ 32)
c. Output Default (DF : 13 / Range : 1 ~ Max)
Remote TV support a / b / c item. TV and PCTV only support
c item.
Erp Time
OFF
0=OFF
30
MINUTE
Belt Stop function for user’s existence detect.
6.2 eNGiNeeriNG mode oVerVieW
fiGUre a
CHaPTer 6: eNGiNeeriNG mode
Содержание T3X-05
Страница 1: ...T 3 x 0 5 T r e a d m i l l S ER V I C E MA N U A l...
Страница 18: ...15 8 1 Electrical DiagramS Chapter 8 Troubleshooting...
Страница 19: ...16 8 1 Electrical DiagramS Continued Chapter 8 Troubleshooting DIgital Communication Wire Grip Sensor Wire...
Страница 20: ...17 8 1 Electrical DiagramS Continued Chapter 8 Troubleshooting H P WIRE KEYPAD Wire...
Страница 77: ...74 NOTES...