2.3 electricAl reQUireMents
cHAPter 2: iMPortAnt sAfety instrUctions
MAtrix dedicAted circUit/electricAl reQUireMent info
All Matrix Ascent Trainers require the use of a 15 amp or 20 amp
“dedicated circuit,” with a non-looped (isolated) neutral/ground, for the
power requirement. Quite simply this means that each outlet you plug
Ascent Trainers into should not have anything else running on that same
circuit besides other Ascent Trainers (up to 3 per 15 amp circuit and 4 per
20 amp circuit). The easiest way to verify this is to locate the main circuit
breaker box, and turn off the breaker(s) one at a time. Once a breaker
has been turned off, the only thing that should not have power to it are
the Ascent Trainers in question. No lamps, vending machines, fans, sound
systems, or any other item should lose power when you perform this test.
Non-looped (isolated) neutral/grounding means that each circuit must have
an individual neutral/ground connection coming from it, and terminating at
an approved earth ground. You cannot “jumper” a single neutral/ground
from one circuit to the next.
In addition to the dedicated circuit requirement, the proper gauge wire
must be used from the circuit breaker box, to each outlet that will have the
maximum number of units running off of it. If the distance from the circuit
breaker box, to each outlet, is 100 ft or less, then 12 gauge wire may be
used. For any distance greater than 100 ft from the circuit breaker box to
the outlet, 10 gauge wire must be used.
For your safety and Ascent Trainer performance, the ground on this circuit
must be non-looped. Please refer to NEC article 210-21 and 210-23. Your
Ascent Trainer is provided with a power cord with a plug listed below and
requires the listed outlet. Any alterations of this power cord could void
all warranties for this product. Multiple Ascent Trainers can be powered
on one dedicated circuit. (3 units per 15 Amp and 4 units per 20 Amp
dedicated circuit.)
Содержание A3x-01 Ascent Trainer
Страница 1: ...A 3 x 0 1 A s c e n t T r a i n e r SER V ICE M A N U A l ...
Страница 2: ......
Страница 5: ...1 Chapter 1 Serial number location 1 1 ASCENT TRAINER SERIAL NUMBER LOCATION SERIAL Number Placement ...
Страница 19: ...15 Chapter 7 TROUBLESHOOTING 7 1 Electrical Diagrams ...
Страница 20: ...16 7 1 electrical diagrams Chapter 7 TROUBLESHOOTING Wiring Diagram Instructions ...
Страница 21: ...17 Chapter 7 TROUBLESHOOTING 7 1 electrical diagrams P05 Console Cable P04 Pulse Sensor Wire ...
Страница 22: ...18 7 1 electrical diagrams chapter 7 troubleshooting P02 Elevation Wire P14 ECB Load Wire ...
Страница 52: ...48 Chapter 8 Part Replacement Guide 8 17 link arm replacement continued ...
Страница 68: ...64 notes ...