7.3 troUblesHooting - keyPAd issUes
cHAPter 7: troUblesHooting
All or soMe of tHe fUnction keys do not resPond
Possible cAUses:
1) The keypad connection ribbon cable has not been plugged in correctly.
2) The keypad is damaged.
3) The console is damaged.
solUtion:
1) Check the connections of the keypad at the Upper Control Board.
a. Remove the console from the console mast.
b. Remove the 6 screws holding the back of the console to the front (Figure A).
c. Inspect the keypad ribbon cable connection at the UCB (Figure B).
d. Even if the keypad ribbon cable appears to be connected correctly, unplug and re-seat the cable, then retest.
2) Replace the affected keypad.
3) Replace the console.
figUre A
figUre b