a
b
1.5mm
c
1
2
DOOR GUIDE
INSIDE
VIEW
SILICON
SILICON
SILICON
OUTSIDE FACE
INSIDE
VIEW
THIS PAGE SHOWS THE PANEL INSTALLATION FOR A
LH CORNER. REVERSE FOR RH.
STAGE 4
SOAPY
WATER
This stage is describing the fitting of the fixed panel for a LH Corner, reverse for RH Corner. Before fitting the fixed glass
panel adjust the threshold extrusion so that the side panel is at right angles to the threshold extrusion. Loosen the
threshold adjuster and lightly tighten in position as required.
a
.Remove and set aside the door guide from the threshold extrusion before fitting the fixed glass panel.
b.
Apply a bead of silicon along the outer inside edge of the threshold in the recess provided (b) in the threshold extrusion and
around either side of the recess where the door guide fits into the threshold extrusion (a).
c.
Lightly wet the edge of the fixed panel
with soapy water and gently lower the panel down into the threshold extrusion first then
along into the wall mount.
d.
As a guide the end of the fixed panel should be positioned 1.5mm away from the cut out in the threshold track (c) further slight
adjustments may be required during the fitting of the closure panel.
a.
Re-fit the door guide.