- 17 -
RC dIG
– digital (torch with Up/Down buttons)
Preinstalled programs tables are listed on page 82.
DYNAMICS mode
By pushing the Dynamics 3 button (Pic. 5) we switch to the arc hardness setting mode. The hardness is set by
selector 8 (Pic. 5). Confirm the settings by pushing the Dynamics button again or by waiting until the time limit
runs out. The settings are saved in both cases. The mode can be selected and saved regardless of the program type
(user or preset).
Setting of welding voltage and wire feed speed
The welding voltage value is selected by selector 5 (Pic. 5).
The welding wire feed speed is adjusted by selector 8 (Pic. 5).
Problems solving
ERROR MESSAGE DISPLAY
During machine operation some errors and breakdowns may appear which will be announced by an Err sign and
error code. The following ones are important for the user:
Err - t-
(TEMP – overheating)
Activation of the machine heat protection. Wait till the machine cools down and then continue your work.
Err 1
(POWERSUPPLY – over/under voltage in the power supply)
The input clamps’ voltage (power supply cable) is outside the machine toleration.
Err 8
(ERR OUT SHORT)
When turning the machine on – short on the input clamps (for instance the grounding cable and cable with the
electrode holder are shorted, or it can signify a machine problem).