- 12 -
FE1
C0,8 CO
2
– wire 0,8 mm
FE2
0,8
82% Ar, 18% CO
2
– wire 0,8 mm
FE3
C1,0 CO
2
– wire 1,0 mm
FE4
1,0
82% Ar, 18% CO
2
– wire 1,0 mm
FE5
C1,2 CO
2
– wire 1,2 mm
FE6
1,2
82% Ar, 18% CO
2
– wire 1,2 mm
Confirm the selected program by pressing button PROG (pos. 12).
Assumed welding current glows on the left display, on the right display adjusted correction of wire shift.
By the left switch (pos. 5) the voltage correction (from -9,0 to +9,0) is selected. During whirling by the right switch
(pos. 8) the speed of wire is shown on the right display (pos. 13) and assumed welding current on the left display
(pos. 14). Assumed welding current can be adjusted by the right switch.
Deactivation of synergic function
Press button PROG (pos. 12). By switch 8 choose OFF.
Confirm by pressing the buton PROG (pos. 12) again.
Saving of optimized synergic program
After choosing a program and optimization of its parameters we can save it as a new program on any program´s
position Pr 1 – Pr 20.
1.
Optimize parameters
2.
Press button SAVE
3.
Choose number of program under which you want to save it.
4.
Hold the SAVE button until symbol
-S-
is shown on display. Now the new program is saved.
Saving of created program without synergic
1.
Set parameters
2.
Press button SAVE
3.
Choose number of program under which you want to save it.
4.
Hold the SAVE button until symbol
-S-
is shown on display. Now the new program is saved.