MAINTENANCE OF THE MACHINE
By
Description
5
Table Of Maintenance Scheduled
Periodic
TYPE OF VERIFICATION
OR MAINTENANCE
Method
Cadence
DATE VERIFICATION AND MAINTAINER NAME
1
2
3
4
5
1
GENERAL CONTROL OF THE
STATE OF THE AIR PURIFIER
Visual
Daily
2
Cleaning
Manual
See Note A
3
CHECKING THE CONDITION
OF THE SEALS
Visual
150 HOURS
4
CONTROL OF THE
TIGHTENING OF THE BOLTS
Manual
150 HOURS
5
FILTER CLOGGING
CONTROL
VISUAL OR
MANUAL
600 HOURS See
Note B
6
CHECKING THE VACUUM
CLEANER
Manual
See Note C
7
BEARINGS CHANGE
Manual
40000 HOURS
See Note D
NOTE THE
The Intervals of Cleaning Are Closely in Correlation To Type Of Fluid Carried To To His Concentra�on, Over That The environment
Of Work To which it is Exposed. Is So Must That The user Final Determine A cadence of Cleaning Such That The Machine Is All
the �me Perfectly Clean And That On Party Fixed Not Yes Are a Create Accumula�ons Of Material Stra�fied For Over 5 mm of
Thickness.
NOTE B
The Replacement Of Filters Is Reported From one Affixed Device This Of Series On the equipments Anyway Should Check What
Was Of Clogging In order to Can Have All the �me The Maximum Suc�on And the Maximum Efficiency Of Machine And So Would
Preferable Give a cadence of Cleaning What Indicated In Paragraph Of Detail Filters Over That Replace At least A Time Per year
All The Set of Filters. Also If you don't Used O�en i Filters Yes Deteriorate Anyway.
NOTE C
Is Must Monitor The vacuum cleaner With a cadence Determined By the user For Verify The Correct Opera�on, That There Are
Damage The Breaks To Impeller And That The Engine Electric Is in Good Condi�ons.
NOTE D
This Is The Life Time for The Which one Are States Sized i Bearings, This Not Removes That For causes External, What Can Be
Vibra�on Higher To Standard For Some Periods The Replacement Should Future Also i Periods More Short. Ending The Their
Cycle of Life, Also Is Apparently Not Have Problems Yes Recommend Of Make Anyway The Replacement Of Bearings.