16
MLI Ultra 12/1250, 24/1250
– User and Installation Manual
Menu
Description
Default
Adjustable
range
Event levels
Capacity low
Level below which the
Capacity low
event can
be triggered
10%
0-100
Cap. very low Level below which the
Cap. very low
event can
be triggered
0%
0-100%
Battery full
Level above which the
Battery full
event can be
triggered
100
0-100%
High
temperature
Internal temperature of the MLI Ultra serves as
an event source
45°C
30-60°C
Low
temperature
Internal temperature of the MLI Ultra serves as
an event source
5°C
30-60°C
Voltage low
Level below which the
Voltage low
event can be
triggered
12.5V
25.0V
12.25-12.75V
24.5-25.5V
Volt. low
delay
Delay time to trigger the
Voltage low
event after
the level was reached
10s
1-120s
Last time
100%
Last time fully charged serves as an event
source. To prevent damage the batteries must
be charged to the full 100% regularly.
It is a common misconception that Lithium-Ion
batteries should not be fully charged.
31 days
7-60 days
Installer
DOD
To optimize the battery cycle life, the Depth of
Discharge (DOD) is set to 80%.
80%
20-100%
CAUTION!
Changing the
DoD to 100%
will decrease
the cycle life.
SOC 0-10V
out
Select this option if the auxiliary connector is
used to display the State of Charge.
Test batt
safety
Button to test if the battery switches-off when the
'battery safety'-conditions are met.
Test stop
charge
Button to test if the chargers stop charging when
the 'stop charge'-conditions are met.
Factory
settings
Button to reset the MLI Ultra to its default
settings
Events tab
With MasterBus a device can be programmed to initiate an action at another connected device that
supports MasterBus. This is very helpful in automation of your system and is done by means of
event-
based commands
.
In the Events tab you can program the MLI Ultra to act as an event source. Events which occur during
the operation of the MLI Ultra will then trigger actions from other devices.