background image

 

 

 

18 

February 2005 / Mass Sine 5000 / EN

 

6.2

 

117V Inverters 

 

GENERAL 

 

Function apparatus 

supplying of AC equipment 

Models 24/4000 

Manufacturer Mastervolt, 

Amsterdam 

INPUT 

 

Battery voltage nominal 

24V 

Switch off voltage low 

19V 

Switch on voltage low 

22V 

Switch off voltage high 

32V 

Switch on voltage high 

30V 

Maximal ripple 

5% 

Current (nominal load) 

 

200A 

No load 

300mA/7W 

Fuse 

2x160A or 1x250A slow blow   

DC Cable 

4x50mm²/AWG 0 or 2x70 mm²/AWG 2/0 with two jumpers (included). 

OUTPUT 

 

Output voltage 

117VAC, ±5% 

Output waveform 

true sine wave 

Frequency 

60Hz, ±0.01% (50Hz model orderable)  

Nominal power Tamb=40°C 

3500W 

Half hour power Tamb=25°C 

4000W 

Peak power 

7000W 

Cos phi 

All power factors allowed. 

Efficiency nominal 

90% 

CLIMATE 

 

Nominal temperature 

-20 till 40°C / -4°F till 104°F 

Cooling 

Cooling partial conventional / forced with temperature regulated fan 

Humidity 

< 95% relative humidity, non condensing 

ENCLOSURE 

 

Dimensions (hxwxd) 

470x315x254 mm / 18.5x12.4x10.0 inch 

Weight 

25 kg / 55 lbs 

Protection degree 

IP 23 

 

 

STANDARDS 

 

Emission EN 

50081-1:1992 

Immunity EN 

50082-1:1997 

Safety EN 

60950:2000 

 

Содержание Mass Sine 24/4000

Страница 1: ...dam The Netherlands Tel 31 20 3422100 Fax 31 20 6971006 e mail info mastervolt com WEB site www mastervolt com Mass Sine 24 5000 230V AC Mass Sine 24 4000 117V AC Inverter Language English Version V1...

Страница 2: ...2 February 2005 Mass Sine 5000 EN...

Страница 3: ...support applications 8 3 OPERATION 9 3 1 Introduction 9 3 2 Switching on and off 9 3 3 Indicator lights 9 3 4 On the remote control 11 3 5 Maintenance 11 4 INSTALLATION 12 4 1 Environment 12 4 2 Wiri...

Страница 4: ...4 February 2005 Mass Sine 5000 EN...

Страница 5: ...zed and trained personal consistent with the locally applicable standards and taking into consideration the safety guidelines and measures chapter 2 of this manual Save this manual at a secure place 1...

Страница 6: ...t possible errors in the manual and the results thereof 1 6 Identification label The identification labels are located at the backside and in the connection compartment of the product Important techni...

Страница 7: ...s Use the product only with a fuse protecting the wiring between product intput and battery in a technical correct condition in a closed well ventilated room protected against rain moisture dust and n...

Страница 8: ...c must be corrected immediately Not only the batteries but the product as well can become a projectile if your transport is involved in an accident Ensure adequate and secure mounting and always use s...

Страница 9: ...e front of the inverter on on The green lamp inverter on lights up and the inverter will start If you use a remote control panel put the on off remote switch to remote and put the on off switch on the...

Страница 10: ...o switch the inverter on again you must manually switch the inverter off and on When the output is short circuited the inverter will go into overload The overload and ON indicators will flash slowly T...

Страница 11: ...r battery voltage is too low If the failure lamp is lit you can check the nature of the failure on the inverter front 3 5 Maintenance For reliable and optimum function examine your electrical installa...

Страница 12: ...Wiring The routing of the wires has influence on the EMC behavior of the system in which the inverter is a component This is caused by the fact that wires are excellent receivers and transmitters of r...

Страница 13: ...ter CAUTION For safe installation it is necessary to connect the earth PE and neutral N of the inverter output to the central ground insert a RCCB earth leakage switch of 30mA in the inverter output P...

Страница 14: ...cable connection between batteries and inverter as short as possible maximum 3 meters 2 Connect the black negative battery cable to the negative connection bolt right and the red positive battery cabl...

Страница 15: ...t the inverter fuse if the polarity is correct Switching on with incorrect polarity will damage the inverter irreparably The inverter fuse cannot prevent this If the connections are correct check whet...

Страница 16: ...rect diameter Inverter goes on and off LED on and LED low bat are blinking in turn Connections are corroded or bad Tighten the connections If the cables are burned replace them Inverter goes on and of...

Страница 17: ...mm AWG 2 0 with two jumpers included OUTPUT Output voltage 230VAC 5 Output waveform true sine wave Frequency 50Hz 0 01 60Hz model orderable Nominal power Tamb 40 C 4000W Half hour power Tamb 25 C 5000...

Страница 18: ...0 with two jumpers included OUTPUT Output voltage 117VAC 5 Output waveform true sine wave Frequency 60Hz 0 01 50Hz model orderable Nominal power Tamb 40 C 3500W Half hour power Tamb 25 C 4000W Peak po...

Страница 19: ...February 2005 Mass Sine 5000 EN 19 7 DIMENSIONS Figure 7 1 Dimensions inverter 294 11 10 5 21 405 5 315 254 470 241...

Страница 20: ...20 February 2005 Mass Sine 5000 EN 8 INSTALLATION DRAWINGS Figure 8 1 Installation of the Mass SINE DC Fuse DC input AC Output ON OFF _ _ 1 2 3 4 5 6 L1 N PE BATTERY BATTERY...

Страница 21: ...February 2005 Mass Sine 5000 EN 21 Figure 8 2 Option 1 4 x 50mm AWG0 Figure 8 3 Option 2 2 x 70mm AWG2 0...

Страница 22: ...22 February 2005 Mass Sine 5000 EN...

Страница 23: ...117V AC 60Hz art No 25024000 4 Mass Sine 24 4000 117V AC 50Hz art No 25124000 Is in conformity with the provision of the EC EMC directive 89 336 EEC and amendments 92 31 EEC 93 68 EEC The following h...

Страница 24: ...24 February 2005 Mass Sine 5000 EN Snijdersbergweg 93 1105 AN Amsterdam The Netherlands Tel 31 20 3422100 Fax 31 20 6971006 e mail info mastervolt com...

Отзывы: