DRY VACUUM OPERATION
WARNING:
Do not plug the power cord into a power outlet. Make sure the plug is disconnected before changing the
filters.
CAUTION:
Do not vacuum drywall dust, fireplace soot, or ash with standard wet/dry filter. These are fine dusts which
will not be captured by the filter and may cause damage to the motor. When vacuuming fine dust use a
fine dust filter (sold separately).
WARNING:
Be sure to read, understand, and apply information entitled “Safety Guidelines”. Do not vacuum in areas
with flammable gases, vapours, or explosive dusts in the air. Flammable gases or vapours include, but are
not limited to: lighter fluid, solvent-type cleaners, oil-based paints, gasoline, alcohol, or aerosol sprays.
Explosive dusts include but are not limited to: coal, magnesium, grain, or gun powder. To reduce the risk
of health hazards from vapours or dust, do not vacuum toxic materials.
Verify that the power cord is disconnected from
the outlet.
Place the filter retainer on the top of the
cartridge filter and tighten down by turning the
retainer handle clockwise.
In order to prepare your vacuum for dry
vacuuming, make sure the cartridge filter
completely covers the filter cage against the
power head. Your wet/dry vacuum comes with
the cartridge filter pre-installed. For installation
instructions, see page 20.
Place the power head back on the collection
tank and secure it in place using the latches.