background image

21

INSTALLING & CLEANING FOAM WET FILTER

INSTALLING FOAM WET FILTER

CLEANING FOAM WET FILTER

Verify that the power cord is disconnected from 
the outlet. Remove the power head and place in 
an upside down position. Follow instructions to 
remove the cartridge filter on page 20.

With the removed power head in an upside down 
position, carefully remove the foam wet filter.

Carefully slide the foam wet filter down over the 
filter cage making sure the cage is completely 
covered. Place the power head onto the 
collection tank.

Use a mild soap and water solution to wash the 
foam wet filter and rinse with clean water.

Allow the wet filter to air dry for 24 hours before 
installing onto the filter cage.

1

1

2

2

3

Содержание 054-0339-8

Страница 1: ...INSTRUCTION MANUAL WET DRY VACUUM IMPORTANT Read and understand this instruction manual thoroughly before using the product...

Страница 2: ......

Страница 3: ...4 BLOWER OPERATION 16 MAINTENANCE 18 INSTALLING CLEANING CARTRIDGE FILTER 20 INSTALLING CLEANING FOAM WET FILTER 21 TROUBLESHOOTING 22 ACCESSORIES 22 EXPLODED VIEW 23 PARTS LIST 24 WARRANTY 25 Read an...

Страница 4: ...6 U S gallons 13 Imperial gallons Peak horsepower 5 0 HP Power 120 V 60 Hz 10 5 A Tank Plastic Power cord 12 3 65 m Hose 2 1 2 x 7 6 4cm x2 1m Water lift 60 152 4 cm at end of hose Airflow 106 CFM at...

Страница 5: ...grain dust or gun powder Sparks inside the motor can ignite flammable vapours or dust To reduce the risk of health hazards from vapours or dusts do not vacuum toxic materials Do not use or store near...

Страница 6: ...en using as blower Direct air discharge only at work area Do not use wet dry vacuum as a sprayer Do not direct air at bystanders Keep children away when blowing Wear safety goggles SAVE THESE INSTRUCT...

Страница 7: ...lated wet dry vacuum requires extreme care and knowledge of the system and should be done only by qualified service personnel Replacement parts for a double insulated wet dry vacuum must be identical...

Страница 8: ...ly hazardous situation which if not avoided will result in death or serious injury WARNING Indicates a potentially hazardous situation which if not avoided could result in death or serious injury CAUT...

Страница 9: ...Cord Storage Hook 13 Extension Wand x2 4 Filter Cage 14 On Off Switch 5 Caster x4 15 Accessory Storage 6 utility nozzle 16 Latch x2 7 Filter Retainer 17 Vacuum Port 8 Cartridge Filter 18 Collection T...

Страница 10: ...cal shock this appliance has a polarized plug one blade wider than the other This plug will fit in a polarized outlet only one way If the plug does not fit fully in the outlet reverse the plug If it s...

Страница 11: ...nstallation instructions Insert the larger end of the hose into the vacuum port on the power head Your vacuum comes ready for dry vacuum cleaning If the cartridge filter is not installed refer to page...

Страница 12: ...include but are not limited to lighter fluid solvent type cleaners oil based paints gasoline alcohol or aerosol sprays Explosive dusts include but are not limited to coal magnesium grain or gun powde...

Страница 13: ...the required attachment onto the free end of the hose or extension wand Turn the motor on by flipping the switch to the I ON position and begin vacuuming Once you have completed vacuuming flip the sw...

Страница 14: ...in or gun powder To reduce the risk of health hazards from vapours or dust do not vacuum toxic materials Verify that the power cord is disconnected from the outlet Make sure that the collection tank i...

Страница 15: ...g large quantities of liquids do not immerse the nozzle completely in the liquid leave a gap at the tip of the nozzle opening to allow air inflow The machine is fitted with a float valve that stops th...

Страница 16: ...st that might be inhaled BLOWER OPERATION Verify that the power cord is disconnected from the outlet Make sure the collection tank is empty before using as a blower Clear all dirt and debris from the...

Страница 17: ...on the vacuum firmly hold onto the loose end of the hose Turn the motor on by flipping the switch to the I ON position Once you have completed vacuuming flip the switch to the O OFF position Unplug t...

Страница 18: ...e latches and remove the power head from the collection tank Place power head on a soft clean surface upside down Disconnect the hose from the vacuum Clear all dirt or debris from the collection tank...

Страница 19: ...e the filter regularly for best performance ALWAYS USE THE CARTRIDGE FILTER FOR DRY VACUUMING If the machine is used without the cartridge filter the motor will burn out and the warranty will be voide...

Страница 20: ...he filter cage Place the filter retainer on the top of the cartridge filter over the raised lip and tighten down by turning the retainer clockwise do not over tighten Place the power head back onto th...

Страница 21: ...dge filter on page 20 With the removed power head in an upside down position carefully remove the foam wet filter Carefully slide the foam wet filter down over the filter cage making sure the cage is...

Страница 22: ...tion The wet dry vacuum will not operate No power supply Check the power supply cord breakers and fuses Faulty power cord Unplug and check the power cord If damaged have it repaired by a professional...

Страница 23: ...23 EXPLODED VIEW 1 10 11 12 13 14 15 16 2 3 4 5 6 7 8 9 9 5 9 9...

Страница 24: ...h Assy 6 Collection Tank 7 Vacuum Port Assy 8 Drain Cap Assy 9 Caster x 4 10 Hose 11 Extension Wand x 2 12 Crevice Tool 13 Utility Nozzle 14 Cartridge Filter 15 Filter Retainer 16 Foam Wet Filter PART...

Страница 25: ...justments e this warranty will not apply where damage is caused by repairs made or attempted by others i e persons not authorized by the manufacturer f this warranty will not apply to any product that...

Отзывы: