background image

Entrée Bath Gen III

 

INSTALLATION MANUAL 

  
 
 
 
 

01-27-2022 
Page 7 of 9

 

450 East 32

nd

 Street PO Box 1022 (68026) 

Fremont NE 68025 
800-798-5867  Office: 402-564-5867   FAX: 402-563-9102 
www.mastercarebath.com

 

 

 

Note:  The  "U"  section  must  be  installed  "low 
profile" so that it will clear the tub door when in 
open  position.  The  reason  for  the  "U" 
configuration is for  ease  of disconnection  in  the 
event the tub needs to be slid out for service. 

 

MEMO:

 

1.

 

Parts shown in the top view of this 
suggested layout are to be supplied by the 
installing contractor. 

2.

 

All drain connecting parts supplied by the 
contractor must meet National and State 
Plumbing Codes. 

3.

 

If floor sink used, it must be at least three 
inches in diameter. 

4.

 

If rubber coupler does not meet code, use 
any type of detachable coupler that meets 
code to allow drain assembly to be 
uncoupled so tub can be slid out for 
service. 

Wall 

Drain 

Option 

Floor 
Drain 
Option 

40 

1

/

2

R

ea

r W

all

 

Casual Water 

Drain Hose 

19" 

SIDE VIEW OF DRAIN 

CAUTION

:

 

Plumbing 

and 

electrical  installations  must  be 
clear of the full rotational arc of 
the door to the back of the tub.

 

 

1

1

/

4

" off to floor 

Rear Tub 
Service Panel 

L

eft Rear tub leg 

2” 90 PVC close ST 

EL connected to 2” 

tub drain located 

on left rear tub leg 

 

2” rubber coupler

 

- see item # 4 in 

memo below 

 

2” PVC pipe cut to 

length on job site 

2" 90

° 

 PVC EL SxS 

10” From wall 

to center line 

of 2” drain

 

22”

 

2” 90 PVC

 Close 

ST EL connected 

to the 

2” floor 

drain female 
fitting 

2” PVC 

pipe cut to 

length on job site 

2” rubber coupler 

- see item # 4 in 
memo below 

2” 90

° 

 PVC Close ST EL

 

Note

: This "U" portion of drain 

must be installed low 
profile to keep from 
interfering with tub door.

 

Center Line 
of Tub 

End to End 

Note

: Use a straight 90

° 

PVC 

elbow to run to a floor drain

 

     

 

2" PVC 

pipe cut 

to length 

on job site 

2" PVC Tub Drain 

Support Strap 

Rear Left Tub Leg 

Side of Tub 

FRONT VIEW 

TOP VIEW 

Floor 

Rear Tub Lower Service Panel 

Tub Drain Valve

 

Содержание Gen III Entree Bath

Страница 1: ...ollow All Instructions Thoroughly Important safety instructions Read and follow all instructions thoroughly CAUTION The caution heading identifies important maintenance and operation information Failu...

Страница 2: ...Entr e Bath Gen III INSTALLATION MANUAL 01 27 2022 Page 2 of 9 450 East 32nd Street PO Box 1022 68026 Fremont NE 68025 800 798 5867 Office 402 564 5867 FAX 402 563 9102 www mastercarebath com...

Страница 3: ...025 800 798 5867 Office 402 564 5867 FAX 402 563 9102 www mastercarebath com BEFORE STARTING TOOLS NEEDED FOR INSTALLATION Adjustable Wrench Tape Measure Channel Locks Deep and 9 16 Deep Socket and Ra...

Страница 4: ...102 www mastercarebath com ENTR E GEN 2 5 LOCATION REFERENCE v Console Service Access Chair Foot End Controls TOP VIEW OF TUB Back of the Top Front of the Top v High Quality and Wood Stud Floor or Con...

Страница 5: ...he ten 10 lag screws from the bottom of the crate Detail 1 3 Two people will now be required to lift the crate over the top of the Entree Bath 4 Set aside the Entree Gen III Starter Kit box and the Co...

Страница 6: ...b is installed and ready for its test operation Check again to make sure the door is not fully closed and compressing the seal 4 Connect the electrical service to the tub The tub comes with a cord wit...

Страница 7: ...id out for service B Wall Drain Option A Floor Drain Option 40 1 2 Rear Wall Casual Water Drain Hose 19 SIDE VIEW OF DRAIN CAUTION Plumbing and electrical installations must be clear of the full rotat...

Страница 8: ...ctly 17 Make sure that when the fill knob is in the hot position hot water comes out of the valve Check the water temperature and verify it is in the proper range Rotate the knob to mid range and veri...

Страница 9: ...of 9 450 East 32nd Street PO Box 1022 68026 Fremont NE 68025 800 798 5867 Office 402 564 5867 FAX 402 563 9102 www mastercarebath com 20 Make sure the Casual Water Drain located in the back side of th...