GB
3
CT 50 P
START-UP
Load the air heater with fuel through the door of the device up to
the height of about 30 cm from the bottom of the furnace chamber
so that it would be possible to freely close the door and to not
exceed the permissible load mass.
Connect the fan to the mains. Make sure the fan is operating.
Set the fuel on fire and close the door.
In order to increase the quantity of air supplied for burning, a
slight it is permitted to slightly slide out the ash pan (by 2-3 cm)
TYPE OF HEATING
After starting the device, control its operation. Successively
add fuel in order to maintain the operating parameters. Do not leave
the device without control
In the case of observing abnormal operation of the device or
its failure, cause the fire in the furnace to be damped. Remove the
cause of abnormal operation or failure.
(See table 1. Defects, causes and method of removal).
IGNITION OF SOOT IN THE CHIMNEY !!!
Ignition of soot in the chimney signifies the ignition of particles collected
inside the chimney flue (exhaust pipe), which were accumulated during the
operation of the heater, and were not cleaned by chimney sweepers.
In the case of occurrence of fire in the chimney:
•
Call the Fire Brigade, clarifying in details what is happening and how to get
to a given building
•
Damp the fire by careful removal of the inflammable material and tight
closure of the furnace
•
Use the chimney sieve - it is a metal net with mesh size of about 2 x 10
mm, at best copper, spread over the frame with dimensions of 60 x 60 cm,
with two metal holders. Protect the chimney outlet with the sieve and
observe the lower parts of the chimney whether there are no cracks through
which the flames may get out. Prevent the fire spread. Apart from this, the
heated sieve decreases the draught in the chimney, which causes the
intensity of soot burning to be decreased.
•
Pour salt into the chimney outlet on the burning soot.
•
Do not extinguish the fire in the chimney with water, as the sudden
cooling of the chimney and water evaporation may cause chimney
cracks and spread of the fire.
VENTILATION MODE
In order to use only the fan mounted in the device, connect it to the
mains.
At the end of the heating season
disconnect the air heater and
perform the relevant maintenance activities.
Table 1. Defects, causes and method of removal.
Defects
Causes
Method of removal
The fan is not
operable
1. The device is not connected to
the mains.
2.Problem with the power supply
voltage.
3. Damaged power lead.
4. Mechanical interlock of the
fan.
5. Damaged fan.
1.1. Connect the device to
the mains.
2. Check the voltage in the
power supply socket.
3. Replace the power lead
4. Remove the interlock.
5. Replace the fan.
Smoke coming
from the device
is present
inside the room
1. Untight chimney installation.
2. Bad or choked room
ventilation.
3. Ash pan is filled up.
4. The device is overheated –
the fan is not operable or its
operation is not correct.
1. Make the chimney
installation tight
2. Improve the patency or
make the ventilation patent.
3. Empty the ash pan. Clean
the grate
4. Check the operation of the
fan. If it is not operable, see
the defect – fan is not
operable.
Liquid is leaking
from the device.
1. Wet fuel.
1. Use dry fuel.
NOTE: POSSIBLE REPAIRS MUST BE PERFORMED BY
AUTHORISED SERVICE THAT USES ORIGINAL PARTS. IT IS
PROHIBITED TO OPEN AND MANIPULATE THE DEVICE,
EXCEPT FOR THE ACTIVITIES WHICH ARE SUBJECT TO
CHECKING DURING THE MAINTENANCE.
5 USER’S ACTIVITIES
WARNING:
the air heater should be connected to the earthed
electrical socket protected by a differential-current switch.
WARNING:
never disconnect the device from the mains, when it
is hot, as the collected heating power in the heat exchanger may
damage the fan and the heat exchanger.
WARNING:
parts of the heater – in particular, external parts, are
hot during operation, and adequate caution is desirable.
If the power lead which cannot be disconnected is subject to
damage, it should be replaced at the manufacturer’s or at a
specialist’s repair workshop or by a qualified person in order to
avoid risks.
Also, make sure that the electrical parameters of the power
supply source correspond to the technical data from the manual or
the data appearing on the rated plate of the device.
•
Read carefully the warnings included in the manual, as they
contain essential guidelines concerning safety of the installation,
use and maintenance of the device.
•
The installation should be performed in accordance with the
standards applicable in the country, in which it will be used, in
accordance with the guidelines of the manufacturer, by the qualified
personnel from an authorised service point. An error in the
installation may cause injuries of persons and damage, for which
the manufacturer is not responsible.
•
Check the dispatch and its content. In case of doubts, do not
use the delivered device and contact the vendor.
•
Do not leave the elements of the packaging at a place that is
easily accessible to children, as they constitute a source of hazard.
•
Do not block the air inlet grates.
•
In the case of failure or a defect of the device, switch it off and
do not make attempts to repair it on your own, but ask the
authorised technical service to intervene.
•
From the moment in which you decide to switch off the device,
switch off all other parts that may constitute a hazard.
•
This device may be applied only for purposes for which it was
intended. All other methods of use will be considered inadequate or
even hazardous.
•
Make sure that this manual is always attached to the device.
•
If the device is mounted at a place where disabled persons are
present, it must be mounted in a way ensuring easy access to it for
the users.
•
For combustion, use only solid fuels given in the table. You
must not fill the heater with a quantity of fuel greater than the one
which has been specified.
•
Damping the fire in the furnace by flooding it with water is not
allowed.
•
The introduction of structural changes in the heater on your
own is not allowed.
•
This appliance is not intended for use by persons (including
children) with reduced physical, sensory or mental capabilities, or
lack of experience and knowledge, unless they have been given
supervision or instruction concerning use of the appliance by a
person responsible for their safety.
•
Children should be supervised to ensure that they do not play
with the appliance.
In order to ensure proper functioning and adequate
maintenance of the device, we recommend that the authorised
technical service perform periodical maintenance activities at least
once a year, at best at the end of the heating season. Any
interferences in the device may be performed only when it is cold.
Cleaning the heat exchanger at the end of the heating season
Act in the following way:
•
Clean the elements of the heat exchanger with a small brush.
•
Suck the soot which could fall off the replaceable elements in
the furnace by means of an aspirator.
•
Replace the grate, if it is deformed.
•
Clean the external surface of the heat exchanger.
Cleaning chimney pipes
Remove all possible obstacles and / or soot, which could have
accumulated in them.
Air fan
Clean it using a brush or compressed air.
6 RECOMMENDATIONS
7 BASIC MAINTENANCE ACTIVITIES
Содержание CT 50 P
Страница 63: ......