background image

 

 

 

 

 
 
 

Содержание Alliance MP-CSN-20T

Страница 1: ...MP MCAAlliance Series Anion Combination System 2022 Version MASTER Water Conditioning Corp Installation and Operation Manual...

Страница 2: ...ding 2 Control Valve 2 3 Service and Drain Piping 4 6 Electrical Requirements 7 Brine Tank 7 Filling Combination Unit with Water 8 Control Valve Timer Settings 9 Final Check 10 Manual Regeneration 11...

Страница 3: ...C 800 CF Boxes Note The 20 30 units have Vortech and do not require gravel System Description The anion resin combination units have an MPMCA100 top mounted automatic control valve with an impulse met...

Страница 4: ...ing of the distributor pipe before filling the tank with media Model Gravel Filter Media MP CSU 20T N A CF C 800 MP CSU 30T N A 1 CF C 800 MP CSU 40T 25 lbs 1 CF C 800 MP CST 20T N A CF C 800 MP CST 3...

Страница 5: ...nd tight Do not overtighten 4 Locate the bypass valve assembly that is packaged with the control valve The bypass valve has two red handles that indicate flow direction two threaded connections for th...

Страница 6: ...ctions of the control valve are or 1 copper PVC or sharkbite and are located on the back of the valve body As you face the timer the inlet is on the right and the outlet is on the left Always follow l...

Страница 7: ...imum drain line length is 30 feet with proper sloping the entire length Maximum drain line height is 6 feet above the control valve The drain line must be piped to an open air gap See Figure above Alw...

Страница 8: ...6...

Страница 9: ...es power 24 hours per day We recommend installing a surge protector to protect unit from power surges which are not covered by warranty Brine Tank 1 The brine tank should be located directly beside th...

Страница 10: ...TANK TOO FAST ALL THE CATION RESIN WILL BE FLUSHED TO DRAIN DURING START UP 4 When only water is running to the drain open the inlet and outlet ball valves fully 5 Press the REGEN again until the dri...

Страница 11: ...r DOWN arrows 3 Press the NEXT button If water was tested by Master Water Conditioning follow recommendations on water analysis for hardness setting If tested by an independent lab assume 5 ppm of ura...

Страница 12: ...on bypass valve are open 4 Make sure the control valve timer is plugged into an electrical outlet with power 24 hours per day 5 Check all piping for leaks Note Do not use any iron cleaning treatments...

Страница 13: ...cate that the system will regenerate at the preset delayed regeneration time If you pressed REGEN in error pressing the button again will cancel the request Note If the regeneration time option is set...

Страница 14: ...12...

Страница 15: ...ser pipe seal Insure that riser pipe is properly sealed at o ring seal Inspect pipe for cracks Insufficient brine Check brine float height and clean assembly if necessary Check flow rate capabilities...

Страница 16: ...drain line elevation to height of valve Partially restricted drain line Remove restriction Problem Insufficient Refill to Brine Tank Possible Cause Solution Brine refill control Remove and clean Restr...

Страница 17: ...ervice after Regeneration Possible Cause Solution Injector is too small for system size Install correct injector Brine draw time excessively long due to low water pressure Increase water pressure abov...

Страница 18: ...Motor not operating Replace motor No electric power at outlet Repair outlet or use working outlet Defective AC adapter Replace AC adapter Defective PC board Replace PC board Broken drive gear or driv...

Страница 19: ...ntrol valve does not regenerate automatically but does when UP and DOWN buttons are depressed and held Possible Cause Solution Defective PC board Replace PC board Set up error Check control valve set...

Страница 20: ...18 Error Codes...

Страница 21: ...19...

Страница 22: ...20...

Страница 23: ...21...

Страница 24: ...22...

Страница 25: ...23...

Страница 26: ...24...

Страница 27: ...l be void in the event of damages from external sources or where the conditioner has been operated at pressure in excess of 100 pounds per square inch or at a temperature greater than 100 degrees F or...

Страница 28: ...TY REMAINING IN GALLONS TIME SOFTENING PM 6 35 NEXT NEXT 0 0 CUMULATIVE GPM GAL CURRENT TIME CURRENT FLOW RATE IN GALLONS PER MINUTE TOTAL GALLONS SINCE START UP RESET TO 0 BY PRESSING CLOCK AND REGEN...

Страница 29: ...NEXT AND INSTALLER SETTINGS HARDNESS NEXT REGEN TIME HOUR REGEN TIME MINUTES NEXT CLOCK SET TIME CLOCK 12 00 OR TO CHANGE TIME USE 10 2 00 0ff DAY OVERRIDE Default is OFF NEXT...

Страница 30: ...NORMAL NEXT CALL off CAPACITY X1000 SERVICE CALL INDICATOR NEXT NEXT NEXT NEXT Post BRINE REFILL TIME BACKWASH TIME 1 8 dn 2 __ BRINE RINSE TIME NEXT BACKWASH 2 TIME 3 off NEXT 5 ___ BRINE REFILL NEXT...

Страница 31: ...NEXT AND REFERENCE ONLY VALVE PROGRAMING NEXT Normal SET SYSTEM TYPE NEXT 1 VALVE SIZE NEXT SET 2 off NEXT AND Dp OFF DELTA PRESSURE ONLY SET 3 NEXT off SET 4 NEXT off...

Страница 32: ...IN SEQUENCE REGEN PRESS ONCE FOR NEXT REGEN TIME PRESS AGAIN TO CANCEL REGENERATION PRESS AND HOLD FOR 3 SECONDS FOR IMMED PRESS IN REGEN TO ADVANCE TO NEXT CYCLE MANUAL REGENERATION LOCKING SETTINGS...

Страница 33: ...NEXT AND DIAGNOSTICS DAYS SINCE LAST REGENERATION GALLONS SINCE LAST REGENERATION NEXT NEXT NEXT NEXT MCA BOARD RESERVE CAPACITY CALCULATED PER DAY IN GALLONS USAGE PER DAY IN GALLONS MAXIMUM FLOW RA...

Страница 34: ...ERROR CODES...

Страница 35: ......

Отзывы: