Master Spas Spas 2008 Скачать руководство пользователя страница 29

DOWN EAST (3 -4 PUMP SYSTEMS) - CONTROLS

Jets 1

Touch the “Jets 1” button once to turn pump 1 on or off. If left running, and the pump will 
automatically turn off after 15 minutes.

Jets 2

Touch the “Jets 2” button once to turn pump 2 on or off. If left running, pump 2 will automatically turn
off after 15 minutes.

Jets 3 (if equipped)

This button is used to turn the pump 3 on and off. If left on, this device automatically turns off after 
15 minutes.

Light

Press the “Light” button to turn the light on and off. If left on, the light automatically turns off after 
4 hours.

L.E.D. Light (if equipped)

Press the "Light" button to turn the light on and off. If you wish to change the “function” of the lights,
turn the lights off, then on within 5 seconds. If you wish to leave the lights in the same “function” 
setting for the next use, turn the lights off and do not turn back on for at least 5 seconds.

Mode

Mode is changed by pressing the “Warm” or “Cool” button, then pressing the “Mode” button.

Standard mode

is programmed to maintain the desired temperature. Note that the last measured spa

temperature displayed is current only when the pump has been running for at least 2 minutes. “Std”
will be displayed momentarily when you switch into Standard Mode.

Economy mode

heats the spa to the set temperature only during filter cycles. “Ecn” will display solid

when temperature is not current, and will alternate with temperature when temperature is current.

Sleep mode

heats the spa to within 20°F/10°C of the set temperature only during filter cycles. “SLP” will

display solid when temperature is not current, and will alternate with temperature when temperature is
current.

Filtration

The circulation pump runs constantly for filtration and the ozone generator (if installed) will be enabled.

Freeze Protection

If the temperature sensors detect a drop to below 44°F/6.7°C within the heater, the pump(s) will 
automatically activate to provide freeze protection. The equipment stays on until 4 minutes after 
the sensors detect that the spa temperature has risen to 45°F/7.2°C or higher.

49

DO NOT DIVE.

SPA WATER MAINTENANCE - Schedule

For Spas without Eco Pur™ Filtration System

Day One

1.

Test and adjust total alkalinity if necessary to between 80 to 150 ppm using the pH / alkalinity
increaser or decreaser 1oz. at a time. Wait 15 minutes, retest and adjust if necessary. The pump
should be running on high speed during this time with the air controls closed.

2.

Test and adjust pH, if necessary, to within the range of 7.2 to 7.8 using the pH / alkalinity increaser
or decreaser, 1/2oz. at a time. Wait 15 minutes, retest and adjust if necessary. The pump should be
running on high speed during this time with the air controls closed.

3.

Test and adjust sanitizer level. Add chlorine following label directions to maintain a free chlorine
level of 1 to 3 ppm. If using bromine, adjust feeder to maintain a total bromine level of 3 to 5
ppm. Add bromine tablets to the dispenser if necessary, following label directions.

4.

Add a water clarifier following label directions. If the spa is equipped with an ozone unit, we 
recommend adding an enzyme product in place of the clarifier, following the label directions.

5.

Use a small amount of defoamer only if necessary.

Day Two Skip

Day Three

1.

Test and adjust total alkalinity, if necessary, to between 80 and 150 ppm using the pH / alkalinity
increaser or decreaser, 1oz at a time. Wait 15 minutes, retest and adjust if necessary. The pump
should be running on high speed during this time with the air controls closed.

2.

Test and adjust the pH, if necessary, to within the range of 7.2 to 7.8 using the pH / alkalinity
increaser or decreaser, 1/2oz at a time. Wait 15 minutes, retest and adjust if necessary. The pump
should be running on high speed during this time with the air controls closed.

3.

Test and adjust sanitizer level. Add chlorine following label directions to maintain a free chlorine
level of 1 to 3 ppm. If using bromine, adjust feeder to maintain a total bromine level of 3 to 5
ppm. Add bromine tablets to the dispenser if necessary, following label directions.

4.

Add sequestering chemical, following label directions for maintenance.

5.

If necessary, clean water line with a spa general purpose cleaner or enzyme product. 

6.

Use a defoamer only if necessary.

Day Four Skip

(cont. next page)

28

DO NOT DIVE.

Master Spa Parts - 1068 American Drive, Neenah, WI, 54956, USA

Содержание Spas 2008

Страница 1: ...6927 Lincoln Parkway Fort Wayne IN 46804 800 860 7727 www masterspas com pop08ownman Rev 06 08 2008 MASTER SPAS OWNER S MANUAL...

Страница 2: ...__________________________________________________________________________ Address __________________________________________________________________________________ City _____________________________...

Страница 3: ...tenance Non ECO PUR Spa Water Maintenance Start Up 27 Spa Water Maintenance Schedule 28 29 Water Maintenance Trouble Shooting Guide 30 Why Chemicals are Important in a Spa 31 Maintenance Recommendatio...

Страница 4: ...r safety and the safety of anyone who enjoys the use of your spa is our utmost concern The sign should be mounted with screws or another type of permanent fastener Additional or replacement signs can...

Страница 5: ...oad 73 DO NOT DIVE Legend Series Spas Down East Spas Procedure 5 Rinse filters and reinstall SAFETY INSTRUCTIONS IMPORTANT SAFETY INSTRUCTIONS When installing and using this electrical equipment basic...

Страница 6: ...G Install the spa so that water can be easily drained out of the compartment containing electrical components so as not to damage equipment Also when installing spa allow at least 2 feet of clearance...

Страница 7: ...elpful to use a lubricant use silicone based not petroleum based to allow for an easier turn of the diverter handle Rinse the diverter internals and reassemble In the future it is helpful to turn the...

Страница 8: ...rmit any electric appliance such as a light telephone radio or television within five 5 feet of the spa Never operate any electrical appliances from inside the spa or while wet 12 WARNING RISK OF SUFF...

Страница 9: ...e the jets are open and the air controls are open See page 12 4 Check for dirty filters Clean if necessary SAFETY INSTRUCTIONS IMPORTANT SAFETY INSTRUCTIONS CONT 15 A green coloured terminal or a term...

Страница 10: ...PAS TOUTES EN PLACE WARNING PEOPLE USING MEDICATIONS AND OR HAVING AN ADVERSE MEDICAL HISTORY SHOULD CONSULT A PHYSICIAN BEFORE USING A SPA OR HOT TUB AVERTISSEMENT LES PERSONNES QUI PRENNENT DES M DI...

Страница 11: ...UE LUMINAIRE T L PHONE RADIO T L VISEUR ETC MOINS DE 1 5 M DE CETTE CUVE DE RELAXATION CAUTION MAINTAIN WATER CHEMISTRY IN ACCORDANCE WITH MANUFACTURER S INSTRUCTION ATTENTION LA TENEUR DE L EAU EN MA...

Страница 12: ...2 SHOULDER JETS 3 THERAPY JETS 4 MASTER BLASTER FOOT THERAPY JET 1 NECK JETS 2 SHOULDER JETS 3 THERAPY JETS 4 MASTER BLASTER FOOT THERAPY JET 5 JET DIVERTER VALVE Located on the topside of the spa thi...

Страница 13: ...used for an extended period of time turn valve slightly to allow some water to flow when pump is on to prevent stagnent water from developing in the water lines 7 AIR CONTROL VALVES These are located...

Страница 14: ...Legend Series spas have additional remotes which allow the user to control the jet therapy while remaining in his her seat if applicable By pressing the control one time you will activate the pump Pre...

Страница 15: ...interior wall of your spa The on off switch is located on the topside control panel 16 EQUIPMENT CONTROL SYSTEM This houses the wiring and electrical components necessary to operate the spa 17 SPA HEA...

Страница 16: ...ote Control Legend Series only 21 CIRCULATION PUMP This produces water flow through the heater in the spa and provides the water flow necessary to actuate the ozone generator This fractional HP pump r...

Страница 17: ...ts s T Th he e g gr ro ou un nd d w wi ir re e m mu us st t b be e a at t l le ea as st t 6 6 A AW WG G c co op pp pe er r w wi ir re e a an nd d m mu us st t b be e c co on nn ne ec ct te ed d s se e...

Страница 18: ...ering lift to avoid damage to the lift assembly and the TV housing Note Do not sit on television Note The television communicates with the wireless remote via IR Please note that the IR is a line of s...

Страница 19: ...such as stairs ceilings and walls must be taken into consideration Please have your Master Spas dealer or delivery service review site or installation plans prior to delivery 3 Surface Pad Requirement...

Страница 20: ...cations interferences that are not controlled by Master Spas INSTALLATION INSTRUCTIONS 1 Put spa in final position that allows for access to equipment and spa components 2 Remove front side panel This...

Страница 21: ...rd s are damaged if water is entering the Audio Video compartment or any electrical equipment area if the protective shields or barriers are showing signs of deterioration or if there are signs of oth...

Страница 22: ...lt to change the pH 4 pH or potential hydrogen This is a measurement of the active acidity in the water or it is the measurement of the concentration of active hydrogen ions in the water The greater t...

Страница 23: ...nt and the human body A Chlorine 1 Only one type is good for spa use Sodium dichlor which is a granule fast dissolving and pH neutral 2 Chlorine is an immediate sanitizer B Bromine Note Bromine use is...

Страница 24: ...pumps will automatically activate regardless of spa status If the problem persists contact your dealer or service organization May appear temporarily in an overheat situation and disappear when the h...

Страница 25: ...ions that may not be sensed by the standard sensors Aux freeze sensor protection acts similarly except with the temperature thresholds determined by the switch and without a 4 minute delay in turnoff...

Страница 26: ...g for the next use turn the lights off and do not turn back on for at least 5 seconds THE ADVANTAGES OF ECO PUR filtration Legend Series Spas and Down East Spas Helps remove calcium carbonate and hydr...

Страница 27: ...allons 3 TIMES A WEEK Test water using chemical test strips Adjust sanitizer pH and Alkalinity accordingly ONCE A MONTH Soak your filter elements overnight in a bucket with spa Filter Cleaner and then...

Страница 28: ...low action required for HFL message Heating capacity of the spa will not reset automatically you may press any button to reset SPA WATER MAINTENANCE START UP For Spas without Eco Pur Filtration System...

Страница 29: ...NTENANCE Schedule For Spas without Eco Pur Filtration System Day One 1 Test and adjust total alkalinity if necessary to between 80 to 150 ppm using the pH alkalinity increaser or decreaser 1oz at a ti...

Страница 30: ...ity increaser or decreaser 1oz at a time Wait 15 minutes retest and adjust if necessary The pump should be running on high speed during this time with the air controls closed 2 Test and adjust the pH...

Страница 31: ...bs 47 DO NOT DIVE SPA WATER MAINTENANCE TROUBLE SHOOTING GUIDE Problem Possible Causes How To Fix It Chlorine Bromine Odor Excessive Chlorine or Shock water with non chlorine bromine level shock treat...

Страница 32: ...adds more salts minerals and metals In time the water can become saturated with these dissolved solids and can cause stains or scale to form on the walls of the spa or a scale build up inside the equ...

Страница 33: ...message Heating capacity of the spa will not reset automatically you may press any button to reset MAINTENANCE RECOMMENDATIONS Your spa requires periodic draining and cleaning to ensure a safe healthy...

Страница 34: ...ndard with a 24 hour circulation pump that filters and maintains heat as programmed configured Freeze Protection If the temperature sensors detect a drop to below 44 F 6 7 C within the heater the pump...

Страница 35: ...2 button once to activate the pump Press the Jets 2 button again to turn off the pump If left running the pump will automatically turn off after 15 minutes WINTERIZING YOUR SPA Many people find they...

Страница 36: ...reset GFCI per manufacturer s instructions Drain and refill spa per manufacturer s instructions Clean and condition cover per manufacturer s instructions Clean and condition wood per manufacturer s in...

Страница 37: ...rarily in an overheat situation and disappear when the heater cools If the problem persists contact your dealer or service organization May appear temporarily in an overheat situation and disappear wh...

Страница 38: ...temperature thresholds determined by the switch and without a 4 minute delay in turnoff See your dealer for details Locking the Panel PL Press Time Jets 1 then Warm within 3 seconds When locked the PL...

Страница 39: ...s set at 100 F 37 5 C The last measured temperature is constantly displayed on the LCD Note that the last measured spa temperature displayed is current only when the pump has been running for at least...

Отзывы: