Attachment 4: Dimming Values (CV53, 112)
Value Application
Note
1 ... 32 Voltage in Percent of Track Voltage on Output
1 Unit = approx. 3% of track voltage
1 = 3% of track voltage (0.75V)
32 = 100% track voltage (24V)
+ 64 A1 resp. A3 Is Dimmed Only
A1 = value in CV53
A3 = value in CV112*
+ 128 A2 resp. A4 Is Dimmed Only
A2 = value in CV53
A4 = value in CV112*
+ 192 Both Outputs are Dimmed
*
*
= Command Allocation Value must be added to Voltage Value
Attachment 5: Special Function A1 + A2 + A3 + A4 + A5 (CV55, 57, 114, 116, 118)
Value Application
Note
0
0 = Steady "On" (Standard Operation)
1 ... 15 Flashing symmetrical (Time Base 0.25 sec/value)
symmetric flashing
(1 ... 15)
+ 64
Short Term Function (Monoflop) (Time Base 0.25
sec/value)
output switches off after time out
(1 ... 15)
+ 128
Asymmetric Flashing (1/3 on, 2/3 off)
short "on", long "off"
additional value must be added
(1 ... 15)
+ 192
Asymmetric Flashing (2/3 on, 1/3 off)
long "on", short "off"
additional value must be added
Attachment 5a: Expanded Special Functions A2 + A4 + A5 + A6 (CV57, 116, 118, 120)
Value Application
Note
16
Inverse Coupling with Output A1, resp. A3 or A5
Alternating Flashing
CV57 (A2 with A1)
CV116 (A4 with A3)
CV120 (A6 with A5)
31
Charging Control of Voltage Buffer in Programming
Mode (only A5)
only in CV118: buffer controlled by A5
Attachment 6: Basic Values of Freely Programmable Driving Curve (CV67…CV94)
The programmable driving curve is set to the setting below as basic setting. This setting is not subject to the
reset functions.
Basic values of freely programmable driving curve (CV + Value)
67=6, 68=8, 69=10, 70=13, 71=16, 72=19, 73=22, 74=26, 75=31, 76=36, 77=42, 78=48, 79=54, 80=60,
81=68, 82=76, 83=84, 84=92, 85=102, 86=112, 87=124, 88=136, 89=152, 90=168, 91=188, 92=208, 93=228,
94=232
eMOTION XXL Decoder 14