4. CV - Table
This table shows the default settings of the eMOTION XXL Decoder.
An = Analog
CV Description
Default An Value Note
1 Loco Address (Standard Short)
3
1 - 127
2 Starting Voltage
2
1 - 255 CV2 x (1/255 track voltage)
3 Acceleration Time
3
√ 1 - 255 CV3 x 2ms x (1/255 track
voltage)
4 Braking Time
3
√ 1 - 255 CV4 x 2ms x (1/255 track
voltage)
5 Top Speed
255
√ 1 - 255 CV5 x (1/255 track voltage)
6 Mid Speed
64
1 - 255 CV6 x (1/255 track voltage)
5+6 Programming in Register Mode:
Register 6 = CV No.
Register 5 = Value
---
---
CV5 and CV6 are not affected
7 Software Version
2.0
---
read only
7 Decoder Reset Functions
(3 Ranges available)
---
55
66
77
reset basic setting
reset motor setting
reset lights and functions
8 Manufacturer ID
123
---
read only
9 Motor Frequency
0
√
0 ... 3 0=16 kHz, 1=2 kHz,
2=250 Hz, 3= 60 Hz
13 Function Outputs in Analog Mode
(on if Value Set)
3
√ 0 ... 255 F1 = 1, F2 = 2; F3 = 4, F4 = 8;
F5 = 16, F6 = 32; F7 = 64,
F8 = 128
add the values of the desired
functions!
17 Long Loco Address (high byte)
18 Long Loco Address (low byte)
128
128 ...
10239
high loco address active,
if CV29-Bit5 = 1
29 Configuration Table NMRA
4
√
see attachment 1
49 Configuration Table MASSOTH
2
√
see attachment 2
50 Light: Dimming Value (PMW)
32
√ 1 ... 32 32 = full track voltage
51 Front Light: Command Allocation
128
see attachment 3
52 Rear Light: Command Allocation
64
see attachment 3
53 A1 + A2 Dimming Value
32
√
see attachment 4
54 A1: Command Allocation
1
see attachment 3
55 A1: Special Function
0
√
see attachment 5
56 A2: Command Allocation
2
see attachment 3
57 A2: Special Function
0
√
see attachment 5 + 5a
58 Pause Time for Stop with Reversing
0
√ 0 ... 255 0.5 sec per value
eMOTION XXL Decoder 11