Model: DDU-24/26
Doc. Ref. no. : - m06bom101
Issue no. 09
User’s Manual
Page 21 of 51
6. CONFIGURATION GUIDELINES
6.1 Default Configuration
A DDU-24/26 ships from the factory with following configuration.
Display Type
: Time Display
Time Format : Hour Time Format 24
Date Format : DD.MM
Time Zone Offset : 05:30
Applicable for Serial Input Model:
Baud Rate
: 9600
Stop Bit
: 1
Parity Bit
: None
Applicable for Wireless Input Model:
RFM Receive Channel
: 0
Display Unlock Blink
: BL.10[For NTP it is ON with 1 min]
Password
: 0001
Retransmission
: No
Slave ID
:XXXX[Between 0001 to 9998]
Default Ethernet configuration(For NTP or NTP + PoE Input Model)
IP Address
: 192.168.100.032
Subnet mask
: 255.255.255.000
Gateway
: 192.168.100.001
Primary Server IP Address
: 192.168.100.153
Secondary Server IP Address
: 192.168.100.154
Query Interval Time [When Querying NTP Server] :0016
Query Request Time out
: 02
Query Retry Interval
: 02
Number of Time outs before switching Servers
: 03
Secondary Server Option for NTP
: Disable
Note:
1. Fundamental operation mode (Display Settings) will come in affect immediately of SW change.
Action of CONFIG can be switched during clock operation. No power on/off cycle is required to
change these modes.
2. Default Setting of DDU-26 Same as above configuration but only change in Date Format. In
DDU-26 date Format is DD.MM.YY by Default.
3. Default Setting of DDU-24/26 with NTP or NTP +PoE Same as above configuration but only
change in Display Unlock Blink and Retransmission. In Display Unlock Blink is BLON. Slave ID,
Wirless configuration and Retransmission Features not available. Ethernet Default configuration
available for this model only. Please ignore the Serial Parameter in Default configuration menu if
DDU-24/26 has order with only NTP or PoE option. The configuration can be done through
Telnet for this Option.
4. For NTP Use RJ-45 cross cable when connecting DDU-24/26 directly with GPS Master Clock.
Use RJ-45 straight cable when connect DDU-24/26 through switch.
5. Slave ID of Unit is set in Factory once. You can set Slave Id by Entering in Configuration Menu.
Slave ID will not change in Default Condition.
6.2 Configuration of DDU-24/26:
DDU-24/26
offers facility to the users for configuring communication parameters of serial port,
Display Format Selection, Time Zone Selection, Manual Time Set, Set Default Parameter,
Retransmission selection set by Key or configuration Frame Sent by master GPS-MC-2 over Wireless
and View Current Settings by Key Configuration.