Doc.Ref.No.:m92E/om/101 
Issue No.:09 

9000C

 

 

 
 
 
 
 

INDEX 

 
 

A

PPLICATION 

E

XAMPLE

……………………………………………………………………………………

 

S

PECIFICATION

………………………………………………………………………………………………… 

S

AFETY AND WARNING

……………………………………………………………………………………... 

3

 

C

ONNECTION

…………………………………………………………………………………………………… 

3 

I

NSTALLATION

………………………………………………………………………………………………….. 

4 

O

RDERING CODE

……………………………………………………………………………………………… 

4 

T

ROUBLE SHOOTING

………………………………………………………………………………………… 

4

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Содержание 9000C Series

Страница 1: ...Doc Ref No m92E om 101 Issue No 09 9000C INDEX APPLICATION EXAMPLE 1 SPECIFICATION 2 SAFETY AND WARNING 3 CONNECTION 3 INSTALLATION 4 ORDERING CODE 4 TROUBLE SHOOTING 4 ...

Страница 2: ...vironments with full 3 port isolation between input output and power supply 9000C Series are flexible for DIN rail mounting and easily installable Its compact design consumes less space and hence reduces cost of overall installation 9000C with HART Pass through is dedicated Signal Isolator with HART Pass capability and all enhanced features of 9000C Series and can provide an additional Output of C...

Страница 3: ...racy 0 1 of FS Output Load resistance For 0 4mA to 20mA 750 Ω 600 Ω for HART Pass OP1 For 0 1 to 5V 470 Ω For 0 to 10V 1 KΩ TPS Output Transmitter Power Supply 24VDC Max current Limit 26mA Electronic Power Supply Power Supply 20 to 265VDC AC 45Hz 65Hz Power Consumption 5VA CMRR 100dB NMRR 70dB Isolation Isolation Power to Input Output Input to Output Output to Output 1 5KV AC for 1 minute Environm...

Страница 4: ...icient fuse protection and are of correct size All output cables are of correct size for the maximum device output current or have separate fuse protection Sufficient convection is ensured After installation the terminal area must be covered to provide sufficient protection against unauthorized Access to live parts This is ensured by installing the device in the control Cabinet or distributor box ...

Страница 5: ...fore attempting any re calibration Unstable Reading Check for loose connections First verify that all conventional instrumentation norms have been followed for wiring Make noise away from signal isolator Fluctuation in Reading The reason can be reverse input connections Ordering Code Model Input Type No of O P O P Type 9000C S X X X C 4 20mA 1 One 1 4 20mA 2 Two Model Input Type No of O P O P Type...