background image

 

 

 

 
 
Doc.Ref No.:m92E/om/101 
Issue No.:09 

 

 

 

9000C

 

S

AFETY AND WARNING

 

 

To ensure that the device can be operated safely and  
All function can be used, please read these instructions 
Carefully before installing the device. 

 

 

  Caution: Never carry out work when the Power is 

turned ON, this is dangerous. 

 

Installation  and  startup  must  be  carried  out  by 
qualified  person  only.  The  relevant  country-Specific 
regulations (e.g., VDE, DIN) must also be observed. 

 

Before startup it is particularly important to ensure: 

 

 

Terminal wiring: 
Check  that  all  cables  are  connected  According  to 
the connection diagram. 

 

The Power supply has been connected correctly 

 

Protection is provided against electric shock. 

 

The device can be switched off outside the power 
Supply according to EN 60950 regulations. 
(e.g., by the line protection on the primary side) 

 

All  supply  lines  should  have  sufficient  fuse 
protection and are of correct size. 

 

All  output  cables  are  of  correct  size  for  the 
maximum  device  output  current  or  have  separate 
fuse protection. 

 

Sufficient convection is ensured. 
After installation the terminal area  must be  covered 
to provide sufficient protection against unauthorized 
Access to live parts. 
This  is  ensured  by  installing  the  device  in  the 
control Cabinet or distributor box. 

 

C

ONNECTION

 

 

Connection details: 

 

Block Diagram and connection details of SOP 

 

 

 

Note: In case of DC supply connect DC (+) to terminal no. 
3 and DC (-) to terminal no. 4. 

 

 
 
 

 

 
 

 
Block Diagram and connection details of DOP

 

 

 

Block Diagram and connection details SOP HART 
Pass Suitable for 2 wire transmitter only

 

 

 
 

Block Diagram and connection details of DOP HART 
Pass Suitable for 2 wire transmitter only

 

 

 
 

Note: In case of DC supply connect DC(+) to terminal 
no. 4 and DC(-) to terminal no. 5. 

 

I

NSTALLATION

 

 

Din Rail Mounting: 

 

The  unit  can  be  snapped  onto  all  DIN  rails  (35 
mm) According to EN60715. The device must be 
mounted  horizontally  (Output  terminal  blocks 
facing upper wards). 

Содержание 9000C Series

Страница 1: ...Doc Ref No m92E om 101 Issue No 09 9000C INDEX APPLICATION EXAMPLE 1 SPECIFICATION 2 SAFETY AND WARNING 3 CONNECTION 3 INSTALLATION 4 ORDERING CODE 4 TROUBLE SHOOTING 4 ...

Страница 2: ...vironments with full 3 port isolation between input output and power supply 9000C Series are flexible for DIN rail mounting and easily installable Its compact design consumes less space and hence reduces cost of overall installation 9000C with HART Pass through is dedicated Signal Isolator with HART Pass capability and all enhanced features of 9000C Series and can provide an additional Output of C...

Страница 3: ...racy 0 1 of FS Output Load resistance For 0 4mA to 20mA 750 Ω 600 Ω for HART Pass OP1 For 0 1 to 5V 470 Ω For 0 to 10V 1 KΩ TPS Output Transmitter Power Supply 24VDC Max current Limit 26mA Electronic Power Supply Power Supply 20 to 265VDC AC 45Hz 65Hz Power Consumption 5VA CMRR 100dB NMRR 70dB Isolation Isolation Power to Input Output Input to Output Output to Output 1 5KV AC for 1 minute Environm...

Страница 4: ...icient fuse protection and are of correct size All output cables are of correct size for the maximum device output current or have separate fuse protection Sufficient convection is ensured After installation the terminal area must be covered to provide sufficient protection against unauthorized Access to live parts This is ensured by installing the device in the control Cabinet or distributor box ...

Страница 5: ...fore attempting any re calibration Unstable Reading Check for loose connections First verify that all conventional instrumentation norms have been followed for wiring Make noise away from signal isolator Fluctuation in Reading The reason can be reverse input connections Ordering Code Model Input Type No of O P O P Type 9000C S X X X C 4 20mA 1 One 1 4 20mA 2 Two Model Input Type No of O P O P Type...

Отзывы: