OPEN
4.3 S
TARTING
THE
GENERATOR
Before starting the generator check that all the doors
is closed.
Before starting the generator ensure that all the
preliminary checks have been carried out.
Start
Press the ON/OFF pushbutton (
ref.1
) to turn on the
module. It will show “
mase
” logo on display.
Press and hold pressed the
START
pushbutton (
ref.2
) in
order to preheat the glow plugs (pre-starting) and then
start the engine. Release only when the engine is started,
paying attention to not exceed 5 seconds for each starting
attempt and doing a pause of about 30 seconds between
them.
Repeated unsuccessful starting attempts may cause
excessive accumulation of water in the exhaust
system with possible serious damage
to the engine.
In case of have difficulty in starting the engine,
absolutely do not persist for a long time before first
having closed the seawater intake cock (Ref.3).
During the running-in period (the first 50 hours), do
not apply loads exceeding 70% of the rated power of
the generator.
For more detailed information, consult the manual
provided by the engine manufacturer, which
accompanies each generator.
4.4 S
TOPPING
LHE
GENERATOR
Stop the generator by pressing the
STOP
button on
the control panel (
ref.1
).
The generator can be stopped also by setting the switch
(
ref.4
) to the
“OFF”
position.
Before stopping the generator, it is advisable to run it
for a few minutes without drawing current in order to
allow gradual cooling of the engine and the alternator.
Pressing OFF on thi switch, the module