IS 6.5 - 7.6
13
I
GB
3 AL
TERNA
T
O
R
3 ALTERNATOR
The generators of the
IS 6.5/7.6
series are equipped
with a brushless, synchronous, 4-pole, self-
regulating, self-excited alternator with two
capacitors
(Fig. 7 Ref. 1)
connected to two
auxiliary windings for stator excitation. The alternator
generates alternate voltage available at the
terminals at a frequency of 50/60 Hz (corresponding
to the speed of the prime mover of 1500/1800 rpm)
according to the principle described below.
Upon starting, the rotor magnetism (residual
magnetism of the nucleus) induces a voltage in the
auxiliary excitation windings.
This voltage is applied to the capacitors and makes
a capacitive current circulate in the closed circuit
composed of the capacitor and the auxiliary winding.
This current produces a magnetic field which
strengthens the rotor magnetism generating a
voltage inside it which, rectified by the diodes,
(Fig.
9 Ref. 1)
makes a continuous current circulate in
the rotor field windings.
The rotating magnetic field due to circulation of this
current in its turn generates in the primary winding
the rated voltage to the generator terminals.
TESTS
All the resistance measurements are made with
the alternator cold, ambient temperature 10 - 30
°C, and with instrumentation such as to allow
reading the values indicated.
The tolerance with respect to the values listed is
approximately ± 10%.
Approximate readings made with instruments with
inadequate range, can only indicate continuity of
the winding but do not give an indication of any
short-circuits.
N.B.
Apart from the failure possibilities indicated below,
there might be one or more earth windings. It is
therefore recommended to test these possibilities,
checking with a tester that there is no continuity
between the various windings
(identified in the
following paragraphs)
to earth and between them.
3 ALTERNATORE
I generatori della serie
IS 6.5/7.6
sono dotati di
alternatore senza spazzole, sincrono, a quattro
poli, autoregolato, autoeccitato, con due conden-
satori
(fig. 7 rif. 1)
collegati a due avvolgimenti
ausiliari di eccitazione statore. L’alternatore gene-
ra una tensione alternata, disponibile ai morsetti a
una frequenza di 50/60 Hz. (Corrispondenti alla
velocità del motore primo di 1500/1800 rpm) se-
condo il principio di seguito descritto.
All’avviamento il magnetismo di rotore (magnetismo
residuo del nucleo) induce negli avvolgimenti
ausiliari di eccitazione una tensione.
Questa tensione è applicata ai condensatori e fa
circolare nel circuito chiuso, costituito dal
condensatore e dall’avvolgimento ausiliario, una
corrente capacitiva.
Questa corrente produce un campo magnetico
che rafforza il magnetismo di rotore, generando in
esso una tensione che, raddrizzata dai diodi,
(fig.
9 rif. 1)
fa circolare una corrente continua negli
avvolgimenti induttori di rotore.
Il campo magnetico rotante dovuto alla circolazione
di questa corrente genera a sua volta
nell’avvolgimento principale la tensione nominale
ai morsetti del generatore.
CONTROLLI
Tutte le misure di resistenza si intendono eseguite
ad alternatore freddo, temperatura ambiente 10 -
30 °C e con strumentazione tale da permettere la
lettura dei valori indicati.
La tolleranza rispetto ai valori riportati è
indicativamente ± 10%.
Letture approssimative, eseguite con strumenti di
portata non adeguata, possono unicamente
indicare la continuità dell’avvolgimento ma non
danno indicazioni su eventuali corto circuiti.
N.B.
Oltre alle possibilità di guasto che sono indicate in
seguito si può presentare il caso di uno o più
avvolgimenti a massa. Si consiglia quindi di
controllare queste eventualità verificando con un
tester che non ci sia continuità fra i vari avvolgimenti
(identificati nei paragrafi successivi)
verso massa
e fra gli stessi.
Содержание I.S. 6.5
Страница 4: ...IS 6 5 7 6 4 1 2 3 5 6 7 8 9 4 10 SERIAL No 1 3 2 4 6 9 5 8 7 1 IDENTIFICAZIONE MACCHINA 1...
Страница 6: ...IS 6 5 7 6 6 19 20 21 22 23 1 IDENTIFICAZIONE MACCHINA 11 12 13 14 16 17 17 18 24 25 26 10 15 2...
Страница 8: ...IS 6 5 7 6 8 2 TABELLA ATTREZZI 3...
Страница 10: ...IS 6 5 7 6 10 2 TABELLA ATTREZZI 4...
Страница 14: ...IS 6 5 7 6 14 3 ALTERNATORE 6...
Страница 16: ...IS 6 5 7 6 16 3 ALTERNATORE 7 1 8 2...
Страница 18: ...IS 6 5 7 6 18 1 3 ALTERNATORE 9...
Страница 20: ...IS 6 5 7 6 20 A K A K A K 3 ALTERNATORE 10...
Страница 22: ...IS 6 5 7 6 22 3 ALTERNATORE 11...
Страница 24: ...IS 6 5 7 6 24 4 MOTORE 12...
Страница 34: ...IS 6 5 7 6 34 4 MOTORE 3 2 1 14...
Страница 38: ...IS 6 5 7 6 38 5 SENSORI 16 1 2...
Страница 40: ...IS 6 5 7 6 40 5 SENSORI 17...
Страница 42: ...IS 6 5 7 6 42 18...
Страница 44: ...IS 6 5 7 6 44 5 SENSORI 19...
Страница 46: ...IS 6 5 7 6 46 5 SENSORI 20...
Страница 48: ...IS 6 5 7 6 48 5 SENSORI 21...
Страница 52: ...IS 6 5 7 6 52 1 2 6 RAFFREDDAMENTO 23...
Страница 54: ...IS 6 5 7 6 54 1 2 3 4 6 RAFFREDDAMENTO 24...
Страница 56: ...IS 6 5 7 6 56 1 2 3 4 6 RAFFREDDAMENTO 25...
Страница 58: ...IS 6 5 7 6 58 1 2 6 RAFFREDDAMENTO 26...
Страница 60: ...IS 6 5 7 6 60 1 2 7 REGOLAZIONI 27...
Страница 62: ...IS 6 5 7 6 62 7 REGOLAZIONI 28 2 1...
Страница 64: ...IS 6 5 7 6 64 12 9 8 7 6 10 1 2 3 4 5 11 8 IMPIANTO ELETTRICO 29...
Страница 66: ...IS 6 5 7 6 66 3 3 2 1 8 IMPIANTO ELETTRICO 30...
Страница 68: ...IS 6 5 7 6 68 8 IMPIANTO ELETTRICO 31 32...
Страница 70: ...IS 6 5 7 6 70 8 IMPIANTO ELETTRICO 33 34...
Страница 72: ...IS 6 5 7 6 72 8 IMPIANTO ELETTRICO 35 36...
Страница 74: ...IS 6 5 7 6 74 8 IMPIANTO ELETTRICO 37...
Страница 76: ...IS 6 5 7 6 76 8 IMPIANTO ELETTRICO 38...
Страница 78: ...IS 6 5 7 6 78 Schema di principio Operating principle diagram F1 8 IMPIANTO ELETTRICO 39...
Страница 82: ...IS 6 5 7 6 82 8 IMPIANTO ELETTRICO 41...
Страница 84: ...IS 6 5 7 6 84 8 IMPIANTO ELETTRICO 42...
Страница 86: ...IS 6 5 7 6 86 1 8 IMPIANTO ELETTRICO 43...
Страница 90: ...IS 6 5 7 6 90 9 SMONTAGGIO 45...
Страница 92: ...IS 6 5 7 6 92 1 2 9 SMONTAGGIO 46...
Страница 94: ...IS 6 5 7 6 94 1 2 4 3 9 SMONTAGGIO 47...
Страница 96: ...IS 6 5 7 6 96 1 2 2 9 SMONTAGGIO 48...
Страница 98: ...IS 6 5 7 6 98 2 1 4 3 9 SMONTAGGIO 49...
Страница 100: ...IS 6 5 7 6 100 3 9 SMONTAGGIO 2 1 50...
Страница 102: ...IS 6 5 7 6 102 3 4 2 1 9 SMONTAGGIO 51...
Страница 104: ...IS 6 5 7 6 104 1 2 3 9 SMONTAGGIO 52...
Страница 106: ...IS 6 5 7 6 106 1 2 9 SMONTAGGIO 53...
Страница 108: ...IS 6 5 7 6 108 1 9 SMONTAGGIO 54...
Страница 110: ...IS 6 5 7 6 110 10 TAVOLA RICAMBI 55...
Страница 112: ...IS 6 5 7 6 112 10 TAVOLA RICAMBI 56...
Страница 114: ...IS 6 5 7 6 114 10 TAVOLA RICAMBI 56...
Страница 116: ...IS 6 5 7 6 116 10 TAVOLA RICAMBI 57...
Страница 118: ...IS 6 5 7 6 118 10 TAVOLA RICAMBI 58...
Страница 121: ...IS 6 5 7 6 121 WIRINGDIAGRAM ESQUEMAELECTRICO 59...
Страница 123: ...IS 6 5 7 6 123 VERSIONISPECIALI SPECIAL VERSION...
Страница 126: ...IS 7 6 cod 001351 126 ALLARM 60...
Страница 127: ...IS 7 6 cod 001351 127 61...
Страница 129: ...IS 7 6 cod 001351 129 RICAMBI IS 7 6 cod 001351 SPARE PARTS IS 7 6 cod 001351...
Страница 130: ...IS 7 6 cod 001351 130...