Part list

10.1  Parts List

Section 10 

– 

Repair Part Diagram

Instantaneous Water Heater Part Number - Model begins with "ST"

Kiterarmi #

IOM Ref

Laars #

Description

H120490006

1

ST1001

Exhaust ASS'Y

H110240306

2

ST1002

Case

H110130108

3

ST1003

Door ASS'Y

H110070400

3-1

ST1003

Front Cover

H850150051

3-2

ST1004

MMI Panel Bracket

H850150050

3-3

ST1005

MMI Panel 

S223100028

4

ST1006

Ignition Transformer

H870060043

5

ST1007

Gas Inlet Nipple

S311400020

6

ST1008

Overheat Sensor 

H160420004

7

ST1009

DHW Supply Pipe ASS'Y

S549100124

7-1

ST1010

DHW Supply Pipe

S311300015

7-2

ST1011

Water Outlet Sensor

H160522003

8

ST1012

Siphon ASS'Y

9

ST1013

Siphon Air Pressure Hose

S264100022

10

ST1014

Air Pressure Switch

S264100022

11

ST1015

MMI Bracket

H140350003

12

ST1016

MMI

S114110021

13

ST1017

PCB

H140210024

14

ST1018

PCB Bracket

H140210024

15

ST1019

Manual Switch

S264100048

16

ST1020

Flow Control Valve

H160400003

17

ST1021

Water Inlet Pipe ASS'Y

S549100114

17-1

ST1022

Water Inlet Pipe

S311300013

17-2

ST1023

Water Inlet Sensor

S491100079

17-3

ST1024

Water Inlet Filter

S549100122

17-4

ST1025

Water Inlet Filter Cap

H140120017

18

ST1026

Case Bracket (Left)

H140120017

19

ST1027

Case Bracket (Right)

H110010005

20

ST1028

Intake Air ASS'Y

H120240410

31

ST1029

Heat Exchanger Assembly

S549100112

31-1

ST1030

Exhaust Pipe Assembly(UP)

S319300012

31-2

ST1031

Exhaust Temperature Sensor

S552100063

31-3

ST1032

Exhaust Packing 1

S549100113

31-4

ST1033

Exhaust Pipe Assembly(DOWN)

S552100062

31-5

ST1034

Exhaust Packing 2

S549100113

31-6

ST1035

Condensate Gutter

H160510018

32

ST1036

Blower Assembly

S242100043

32-1

ST1037

Blower

S551200026

32-2

ST1038

O-Ring

S329100019

32-3

ST1039

AGM(Actuator)

H850150044

33

ST1040

Silencer Elbow

H850150043

34

ST1041

Silencer Body

H130120185

35

ST1042

Burner Assembly

S349100022

35-1

ST1043

Burner Head

S554100043

35-2

ST1044

Ignition Rod Bracket

S333100032

35-3

ST1045

Ignition Rod

H870060044

35-4

ST1046

Burner Fixing Bracket

S311400012

35-5

ST1047

Overheat Sensor(Burner)

H130120197

35-6

ST1048

Metal Fiber

S314200007

36

ST1049

Flame Detector

S323100092

37

ST1050

Mixing Valve

S412150048

38

ST1051

Heat Exchanger Temperature Sensor

S311400002

39

ST1052

Overheat Sensor(Heat Exchanger)

S412160031

40

ST1053

DHW Outlet Pipe

S455100087

41

ST1054

Water Hammer Clip

S412150048

42

ST1055

DHW Inlet Pipe

S252100019

43

ST1056

Ceramic Heater

S412190036

44

ST1057

Gas Inlet Pipe 

S412190037

45

ST1058

Gas Supply Pipe (to gas valve)

S345100008

46

ST1059

Gas Valve Adapter (pipe to valve)

H130120185

47

ST1060

Gas Valve Assembly

S171100013

47-1

ST1061

Gas Valve

S171200001

47-2

ST1062

Gas Valve Plug

S345100010

48

ST1063

Gas Valve Adapter(DOWN)

H140010005

49

ST1064

Gas Valve Bracket

H140320008(Left),

50

ST1065

Case Bracket (Heat Exchanger) Left

H140320013(Right)

ST1066

Case Bracket (Heat Exchanger) Right

H140320015

51

ST1067

Case Bracket (Burner)

Cover Assembly

Содержание MSTWW

Страница 1: ...ases which could cause serious injury property damage or death Improper installation and or operation will void the warranty AVERTISSEMENT Assurez vous de bien suivres les instructions donn es dans ce...

Страница 2: ...Lengths 20 4 7 2 Direct Venting 20 4 7 3 Indoor Combustion Air 21 4 8 Vent Air Pipe Termination 21 4 9 Gas Supply and Piping 23 4 10 Gas Supply Pressure 26 4 11 Gas Set Up and Adjustment 26 4 12 Gas...

Страница 3: ...IF YOU SMELL GAS Do not try to light any appliance Do not touch any electrical switch do not use any phone in your building Immediately call your gas supplier from a nearby phone Follow the gas suppl...

Страница 4: ...1 9 9 FUEL N Natural P Propane CONFIG W Wall Hung ALTITUDE A 0 10 000 Feet REVISION 1 First OPTIONS X Standard PUMP X no Pump 1 M SECTION 2 Product Characteristics 2 1 Model Nomenclature The Model Nom...

Страница 5: ...Premixed Fuel Modulation Metal Fiber Infrared Gas Valve System Air ratio valve Minimum Flow Rate 0 5 GPM Internal Pipe Material STS 304 Dimensions W17 3 H28 7 D14 8 Weight 88 lbs Sub Heat Exchanger Wa...

Страница 6: ...g Systems Page 4 Description Diameter A Vent Pipe Collar 3 B Air Intake Collar 3 C Gas Inlet 3 4 D DHW Outlet 3 4 E DHW Inlet 3 4 F Condensate Drain 1 2 G Cold Water Inlet Filter _ 2 3 Dimensions Air...

Страница 7: ...essure Switch 14 Gas Inlet 15 Gas Inlet Pipe 16 Freeze Protector Sensor 17 Domestic Hot Water DHW Outlet 18 Condensate Trap Cleanout Name of Component 19 Cold Water Inlet 20 Cold Water Inlet Filter 21...

Страница 8: ...UR SAFETY READ BEFORE OPERATING If you do not follow these instructions exactly a fire or explosion could result causing property dam age personal injury or loss of life A This appliance does not have...

Страница 9: ...is Water Heater if any part has been under water Immediately call a qualified technician for inspecting the Water Heater and replacing any part of the control system and gas control which have been un...

Страница 10: ...s open position 4 Check the Gas Valve Check that the manual gas shut off valve that supplies the Mascot ST is opened 5 Check the area around the appliance and remove any combustible or flammable mater...

Страница 11: ...a freeze protection function The ceramic heater is installed inside of the heater s internal pipe to protect the heater from freezing Do not wipe the appliance or control panel with wet cloth Electri...

Страница 12: ...ath or substantial property damage The Water Heater which has gas control system components must be protected from any possible danger during operation and service If new Water Heater replaces the exi...

Страница 13: ...drill 4 holes 0 47 dia with a 1 2 drill bit into the wall through the Bracket If mounting to a concrete wall then use the concrete anchors If onto wood or 5 8 16 mm plywood then use the wood screws Do...

Страница 14: ...f total input rating of all equipment in the enclosure When communicating to the outdoors through horizontal ducts each opening shall have a minimum free area of not less than 1square inch per 2000 Bt...

Страница 15: ...emp cher l accumulation de condensat et si n cessaire les chaudi res de cat gories II et IV doivent tre pourvues de dispositifs d vacuation du condensat The Mascot ST is standard as a Natural Gas Wat...

Страница 16: ...ding but not limited to ANSI Z224 1 NFPA 54 CSA B149 1 CSAB149 2 and ULC S636 Failure to follow this manual and applicable codes may lead to property damage severe injury or death INSTALLATIONS IN CAN...

Страница 17: ...rmal insulation covering pipe and fittings is prohibited Do not apply an electric damper draft hood or vent damper with this Water Heater Do not locate vent termination where exposed to prevailing win...

Страница 18: ...enter line extended above meter regulator assembly 3 ft 91 cm within a height 15 ft above the meter regulator as sembly I Clearance to service regulator vent outlet 3 ft 91 cm J Clearance to non mecha...

Страница 19: ...inside corner H Clearance to each side of center line extended above meter regulator assembly 36 in 91 cm within a height 15 ft 4 57 m above the meter regu lator assembly I Clearance to service regul...

Страница 20: ...e wall horizontally vented gas fueled equipment is installed in a crawl space or an attic the hard wired carbon monoxide with alarm and battery back up may be installed on the next adjacent floor leve...

Страница 21: ...ent tre prises pour chaque appareil toujours raccord au syst me d vacuation commun et qui fonctionne alors que d autres appareils toujours raccord s au syst me d vacuation ne fonctionnent pas 1 Scelle...

Страница 22: ...exhaust temperature Tightening Water Heater Collar Socket to Vent Pipe Inlet Pipe Canada has adopted standard ULC S636 which requires the following additional items The following steps for cement appl...

Страница 23: ...um allowable length 5 feet 1 5M for each additional 3 inch 90 degree elbow 2 5 feet 0 75M for each additional 3 inch 45 degree elbow 8 feet 2 4M for each additional 2 inch 90 degree elbow 4 feet 1 2M...

Страница 24: ...ons with Sloped Roof Horizontal Vent Termination cont Direct Vent Optional Sidewall Snorkel Terminations Concentric Vent Termination Direct Vent Optional Horizontal and Vertical Concentric Vent Side w...

Страница 25: ...rify that the appliance is fitted for the proper type of gas by checking the rating plate Mascot ST will function properly at elevations up to 10 000 feet 3050 m Refer to Section 4 12 for High Altitud...

Страница 26: ...n the gas supply line should be installed close to the unit To facilitate any future maintenance it is also recommended that an approved gas union fitting Gas line close position Gas line open positio...

Страница 27: ...tion recommended to be the first appliance to gas supply line Connection 1 2 3 4 Gas pipe size Manual gas shut off valve Gas meter G Capacity not less than total capacity of connected appliances Other...

Страница 28: ...in place This unit was converted on ____ ____ ___to _____gas with kit ____________by______________________ name and company __________________________ accountable _________________________________ WAR...

Страница 29: ...o get into the Installer mode 2 Rotate dial to 9 HA while in installer mode Press the dial to select 9 HA Choose the correct value from the following four options 0 2 0 1 999 ft 0 609 m 2 5 2 000 4 99...

Страница 30: ...ufacturer s instructions supplied with the kit Installation must conform with local codes and the latest edition of the National Fuel Gas Code ANSI Z223 1 and CAN B149 Failure to follow instructions c...

Страница 31: ...ir Gas Mixture AGM Chamber Figure C Figure B away from the blower Keep track of this disassembly as you will need to re assemble exactly as it comes apart Keep all screws and washers 10 Remove the Nee...

Страница 32: ...17 Change dip switches 6 and 7 to a Minimum fire state MIN Fire is 7 ON and 6 OFF 18 Turn ON the Mascot ST 19 Open the manifold pressure port by loosening the screw two turns as shown in Figure D 20...

Страница 33: ...ed on ____ ____ ___to _____gas with kit ____________by______________________ name and company __________________________ accountable _________________________________ _________________________________...

Страница 34: ...3 4 Pipe 500 150m of equivalent length Lengths in excess of these limits will require an external recirculation pump CAUTION Water Quality Potable water is defined as drinkable water supplied from a...

Страница 35: ...rials for the condensate drain lines such as 1 2 PVC CPVC Polypropylene pipe or included plastic hose NOTICE For Category II and IV water heaters be installed so as to prevent accumulation of condensa...

Страница 36: ...he National Electrical Code NFPA 70 and or CSA C22 1 Electrical Code Part 1 in Canada ELECTRICAL SHOCK HAZARD For your safety turn off electrical power supply at service entrance panel before making a...

Страница 37: ...set DIP Switch 5 to OFF for LP Propane hange dip switches 6 and 7 to a Minimum fire state MIN Fire is 7 ON and 6 OFF rn ON the Mascot ST pen the manifold pressure port by loosening the screw two turns...

Страница 38: ...LAARS Heating Systems Page 36 4 19 Wiring Diagram Figure 3 Wiring Diagram...

Страница 39: ...Mascot ST Tankless Water Heater Page 37 4 20 Ladder Diagram Figure 4 Ladder Diagram...

Страница 40: ...SMW250 03 1 RS 485 RS485 SELV 5VDC 2 RS485 SELV 5VDC 3 CN4 LWD1140 06 1 FAN Not Used 2 GND SELV 30VDC 3 VDD SELV 14VDC 4 Fan power start coil SELV 30VDC 5 Fan power end coil SELV 30VDC 6 Fan speed fe...

Страница 41: ...VDC 7 VDD SELV 24VDC CN10 SMW250 08 1 DHM DHM Stepper motor coil Y phase SELV 14VDC 2 DHM Stepper motor coil Y phase SELV 14VDC 3 DHM Stepper motor coil X phase SELV 14VDC 4 DHM Stepper motor coil X p...

Страница 42: ...nt LOW Range 95 120 F 35 49 C DHW Set Point HIGH Range 121 140 F 49 5 60 C D Toggle C F E Scroll Select Turn to scroll tap to select clockwise or counterclockwise The Control Display has a Control Dia...

Страница 43: ...oint can be adjusted WARNING Do not use this appliance if any part has been under water Immediately call a qualified service technician to inspect the appliance and to replace any part of the control...

Страница 44: ...e Control Display will go through a Start Up checklist and briefly show a sequence of diagnostic codes before entering into the Operating Mode It will then display the following information Indicate E...

Страница 45: ...rpm value C Lc Lock Mode Lock mode is used On or unused oFF d OP OP Temperature Current Operating Temperature E dH DHW temperature Current DHW temperature F Eh Exhaust Temperature Current Exhaust tem...

Страница 46: ...40 F When changing DHW setpoint the DHW icon will flash S24 Changing between Celsius and Fahrenheit When the button D is pressed for more than 5 seconds temperature unit will toggle between C and F Th...

Страница 47: ...Reset Number of Ignition 8 dl Maximum fan Adjust to maximum fan value default 0 9 HA High Altitude Settings Choose from 0 2 2 5 5 8 and 8 10 thousands ft of altitude These changes are to be made only...

Страница 48: ...5 Control Display and Operation Flashing Indicate Example Error Er will flash Er 11 Error Code Er 11 Display and Controller are communicating NOTE When communication between the Control Display and t...

Страница 49: ...esistance is zero replace the sensor 5 If the problem persists replace the main control Soft Lock 20 High Limit Overheat Switch Closed is Normal Open is Fault Press the Power button to clear the Error...

Страница 50: ...OP Follow the instructions on page 2 this manual and call a qualified service technician or the fuel gas utility Press the Power button to clear the Error Code If Error happens again 1 Check the water...

Страница 51: ...ondition is remedied If Error happens again 1 Check the water heater cover Ensure it is secure Flame detection sensor can detect an external light source 2 Check flame detection sensor Ensure connecti...

Страница 52: ...LAARS Heating Systems Page 50 1 Flame Detection 6 2 Fault Tree Analysis Section 6 Error Codes 2 Gas Detection...

Страница 53: ...age 51 3 Fan Air Proving 6 2 Fault Tree Analysis Section 6 Error Codes 4 I T DHW OP Sensor detects Error code contents E31 Inlet water NTC open or short E32 DHW NTC open or short E33 OP NTC open or sh...

Страница 54: ...ect Check if the supply and manifold gas pressures are in accordance with specifications Make sure that the water flow sensor with three wires has been properly connected on the top of heat exchanger...

Страница 55: ...on control panel but water heater is oper ating Occurs when the communication is lost from the control to the display Check for loose connec tions and proper pin alignment engagement on the Control s...

Страница 56: ...ent at blower connections Water heater is in standby mode and fan is not running If FAN SPEED is not 0 RPM then replace the fan IGNITION FAULT Even if water heater went through 8 ignition attempts but...

Страница 57: ...charge end of the condensate drain tubing Make sure that no flue gas is escaping from the condensate drain tubing If flue gas is continuously escaping it is a serious problem Call your qualified servi...

Страница 58: ...ront cover And then reconnect the power supply to the water heater 8 Press Power button on the front panel to turn on water heater Cleaning cold water Inlet Filter Draining the Water Heater 1 Place a...

Страница 59: ...er Visually inspect for leaks around internal water piping Also inspect external water piping circulators relief valve and fittings Immediately call a qualified service technician to repair any leaks...

Страница 60: ...wall Is there space for a drain which is close to the Water Heater Are there any combustible materials near the Water Heater and vent pipe Is the air supply sufficient for proper operation of the Wat...

Страница 61: ...ater heater Is the pressure relief valve of DHW Plumbing at least 3 4 in diameter Have you installed the pressure relief valve on the hot water outlet pipe near the Water Heater Final check Burner fla...

Страница 62: ...40210024 14 ST1018 PCB Bracket H140210024 15 ST1019 Manual Switch S264100048 16 ST1020 Flow Control Valve H160400003 17 ST1021 Water Inlet Pipe ASS Y S549100114 17 1 ST1022 Water Inlet Pipe S311300013...

Страница 63: ...Mascot ST Tankless Water Heater Page 61 Cover Assembly...

Страница 64: ...35 ST1042 Burner Assembly 35 1 ST1043 Burner Head 35 2 ST1044 Ignition Rod Bracket 35 3 ST1045 Ignition Rod 35 4 ST1046 Burner Fixing Bracket 35 5 ST1047 Overheat Sensor Burner 35 6 ST1048 Metal Fiber...

Страница 65: ...2 49100113 31 6 ST1035 Condensate Gutter 160510018 32 ST1036 Blower Assembly 42100043 32 1 ST1037 Blower 51200026 32 2 ST1038 O Ring 29100019 32 3 ST1039 AGM Actuator 850150044 33 ST1040 Silencer Elbo...

Страница 66: ...LAARS Heating Systems Page 64 Notes...

Страница 67: ...Mascot ST Tankless Water Heater Page 65 Notes...

Страница 68: ...chester NH 03867 603 335 6300 Fax 603 335 3355 1869 Sismet Road Mississauga Ontario Canada L4W 1W8 905 238 0100 Fax 905 366 0130 www Laars com Litho in U S A Laars Heating Systems 1503 Document 1316 D...