Mascot ST Tankless Water Heater
Page 35
4.18 DIP Switches
There is one set of DIP switches.
DIP switches 6 and 7 must be set to OFF when operating the water heater normally.
Shown in it’s actual
orientation in the unit.
Maximum flame detecting voltage
2.4V
Pre-purge time (Tp)
Maximum 10s, minimum 1s
Safety Time (igniting time) (Ts)
3.5s
Igniting interval time
<10s
Post-purge time (Tip)
180s
Over-heating 1,2,3 protection detection time
<1s
Temperature sensor fault detection time
<2s
Nr. of trial for ignition (Ntl)
10
DHW water SET temperature range
35°C~ maximum DHW setpoint temperature(default: 60°C)
DHW water OFF temperature
DHW target tempe DHW differential temperature(15°C)
DHW water ON temperature
Below DHW target tempe3°C
DHW water ON minimum water flow
2ℓ(12Hz)
DHW water OFF minimum water flow
1.5ℓ(8Hz)
Table 14.
System Control Settings
Customer Service and Product Support:
800.900.9276 • Fax 800.559.1583
Headquarters:
20
Industrial Way, Rochester, NH 03867 • 603.335.6300 • Fax 603.335.3355
1869 Sismet Road, Mississauga, Ontario, Canada L4W 1W8 • 905.238.0100 • Fax 905.366.0130
www.Laars.com
Litho in U.S.A. © Laars Heating Systems 1503 Document 4286
800.900.9276
•
Fax 800.559.1583
(Customer Service, Service Advisors)
20 Industrial Way, Rochester, NH 03867
•
603.335.6300
•
Fax 603.335.3355
(Applications Engineering)
1869 Sismet Road, Mississauga, Ontario, Canada L4W 1W8
•
905.238.0100
•
Fax 905.366.0130
www.Laars.com
Document 4286
M
ascot ST Gas Conversion Kit
pg 3 of 4
Table B
DIP Switch Settings
Figure D
15.
Turn
ON
the GAS and
WATER supply to the Mascot ST.
NOTE:
If your Mascot ST is installed at an altitude greater than 2,000 ft, then the correct altitude setting should have been
set previously and saved within the Control Display. If this has not been done, then Refer to Section 4.12 of the
Mascot ST Install and Operating Manual (document #1316) before continuing with this Gas Conversion.
16.
Per Table B, set DIP Switch
5 to OFF
for LP Propane
.
17.
Change dip switches 6 and 7 to
a Minimum fi re state
(MIN Fire is -
7 ON and 6 OFF
)
18.
Turn
ON
the Mascot ST.
19.
Open the manifold pressure port by loosening the screw two turns as shown in Figure D.
20.
Connect a manometer to the manifold pressure port. For dual port manometers, use the positive pressure side.
21.
While operating the water heater, check CO2 measurement and refer to Table C
22.
Adjust the Cap Screw / Offset Adjustment (See Figure D) until you are within range of Table C.
23.
Turn
OFF
the Mascot ST.
24.
Repeat steps 17 thru 23 at
MAX
Fire by changing DIP switches 6 and 7.
BUT
Do NOT ADJUST MAX FIRE.
If the MAX FIRE is too Low, then go back to MIN FIRE and adjust MIN FIRE to come up.
If the MAX FIRE is too high, then go back to MIN FIRE and adjust MIN FIRE to come down. Repeat this
process between the MIN FIRE settings and MAX FIRE settings (
without adjusting at MAX FIRE
) until both
MAX and MIN are within allowable CO2
as per Table C.
WARNING
ON
OFF
#
MIN
Fire
Normal Operation
7
MAX
Fire
Normal Operation
6
NG Natural
LP Propane
5
Inlet fl ow
Over-ride ON
Inlet fl ow
Over-ride OFF 4
Normal Operation
Do Not Touch
3
Normal Operation
Do Not Touch
2
Normal Operation
Do Not Touch
1
Always make sure that the Control Display is turned
OFF
before changing any DIP switch. Then turn Control Display
back ON to continue with CO2
measurements.
DIP Switch Function
OFF
ON
1-3
Machine power
Do NOT Move.
4
OVER-RIDE
Inlet DHW Flow Limiter
OFF
ON
5
Propane or Natural Gas
LP
NG
6
Max.
Normal
MAX Fire
7
Min.
Normal
MIN Fire
Table 15. Dip Switches
Содержание MSTWW
Страница 38: ...LAARS Heating Systems Page 36 4 19 Wiring Diagram Figure 3 Wiring Diagram...
Страница 39: ...Mascot ST Tankless Water Heater Page 37 4 20 Ladder Diagram Figure 4 Ladder Diagram...
Страница 52: ...LAARS Heating Systems Page 50 1 Flame Detection 6 2 Fault Tree Analysis Section 6 Error Codes 2 Gas Detection...
Страница 63: ...Mascot ST Tankless Water Heater Page 61 Cover Assembly...
Страница 66: ...LAARS Heating Systems Page 64 Notes...
Страница 67: ...Mascot ST Tankless Water Heater Page 65 Notes...