background image

2

SAFETY INFORMATION: Always read before proceeding.

WARNING

These instructions contain information and warnings that are necessary for
safe operation and maintenance of the Veritest. It is recommended that you
read the instructions carefully and ensure the contents are understood.
Failure to understand the instructions and comply with warnings and
instructions herein can result in serious injury, damage or even death.

In order to avoid the danger of electrical shock, it is important that proper
safety measures are taken when working with voltages exceeding 30V AC
rms, 42V AC peak or 60V DC. Never exceed the maximum allowable input
level for each function and range. Refer to the specifications for maximum
inputs. Never touch exposed wiring, connections or live circuits. 

The Veritest must only be used in conditions and for the purpose which it
has been constructed. Attention should be paid to safety instructions,
technical specifications and use of the Veritest in dry surroundings.

Always inspect your meter, test leads and accessories for any sign of
damage before use. If any abnormal conditions exist (e.g: broken test leads,
cracked case, display not reading, etc.), do not attempt to use it. Do not
expose it to direct sunlight, excessive temperature or moisture.

Keep these instructions for future reference. Updated instructions and
product information are available at: www.martindale-electric.co.uk

SYMBOLS:

Equipment complies with relevant EU Directives

AC (Alternating Current)

Ground

Direct Current

Equipment protected by Double Insulation (Class II)

Caution - refer to accompanying documents

Caution - risk of electric shock

10. OPTIONAL ACCESSORIES

Infra red data lead 

VRTL1

Download software

VRSOFT1

Mini printer

VRPRINT1

Data Lead VRPRINT1 to VR2240 

TL130

Test lead (GB 13A plug)

TL206

Fused test lead set

TL54

11. MAINTENANCE

Cleaning
Maintenance consists of periodic cleaning. 

The exterior of the instrument can be cleaned with a dry clean cloth to
remove any oil, grease or grime. Never use liquid solvents or detergents.

Repairs or servicing not covered in this manual should only be performed by
qualified personnel.

Calibration
The recommended calibration interval is 12 months.
Martindale Electric will carry out routine calibration (on a chargeable basis) if
the instrument is returned, carriage paid, to the address on the final page of
this document. Alternatively, a chargeable collection and return service is
available.

Repair & Service
There are no user serviceable parts in this unit. Return to Martindale Electric
if faulty. Our service department will promptly quote to repair any faults that
occur outside the warranty period.

Storage Conditions
The Veritest should be kept in warm, dry conditions away from direct sources
of heat or sunlight and in such a manner as to preserve the working life of the
instrument. 

Warranty
Faults in manufacture and materials are fully guaranteed for 24 months from
date of invoice and will be rectified by us free of charge, provided the unit has
not been tampered with and is returned to us with its housing unopened.
Damage due to dropping, abuse or misuse is not covered by the guarantee.
Nothing in these instructions reduces your statutory rights.

19

Содержание VERITEST 2240

Страница 1: ...G Motor Maintenance Equipment G Non trip loop testers G Pat testers Accessories G Phase rotation G Proving units G Socket Testers G Thermometers Probes G Test Leads G Voltage Indicators G Specialist...

Страница 2: ......

Страница 3: ...ads 3 2 LOW continuity test 4 3 M insulation test 5 4 RCD test 6 5 Loop Zs IK 9 6 Non Trip Earth Loop Impedance Test Ra15mA 10 1 resolution with PFC calculation 7 Phase Rotation Sequence 11 8 Instrume...

Страница 4: ...rrent Equipment protected by Double Insulation Class II Caution refer to accompanying documents Caution risk of electric shock 10 OPTIONAL ACCESSORIES Infra red data lead VRTL1 Download software VRSOF...

Страница 5: ...219mA the instrument has a stored value for the resistance of the test leads current supplied by instrument during calibration procedure function selected FUNC GO NON TRIP EARTH LOOP TEST RA15MA Meas...

Страница 6: ...ds Use to adjust time up and down respectively At the end of the test if the resistance value is lower than 5 the instrument beeps twice indicating low resistance The resistance value is displayed on...

Страница 7: ...be adjusted from 10 999 seconds Adjust values using or This test can be used if a minimum measuring time is required UN I n FUNC L S UL M GO 100V 250V 500V 1000V Low resistance 5 seconds 10 seconds 10...

Страница 8: ...on display by O B Press the yellow key twice The instrument injects a current in phase with negative half wave of the voltage indicated on display by 180 FUNC UN I n L S S UL M GO GO 9 SPECIFICATION...

Страница 9: ...ct to the voltage Readings below 1 are displayed as 1 PLEASE NOTE MAN x5 and auto test modes are not available for RCD type A 500mA 8 INSTRUMENT CONNECTION TO PC OR A PRINTER The connection from the V...

Страница 10: ...st passed Please refer to the full user manual for tripping times Press to scroll through the test results RAMP The instrument generates a leakage current growing step by step in a given time interval...

Страница 11: ...Connect the mains plug to a 230V 50HZ socket outlet or to the appropriate conductor by means of the croc clips 4 Press key repeatedly to select P PE P PE is shown 5 Press the yellow key once The inst...

Страница 12: ...nt Icc UN Ra When UN phase to earth voltage 127V if 100V Vmeas 150V 230V if 150V Vmeas 265V This test is carried out at 15mA 10 UL M GO 7 PHASE ROTATION SEQUENCE 1 Connect red black and green test lea...

Отзывы: