background image

VERITEST 2240

ALL-IN-ONE

MARTINDALE

E L E C T R I C

Trusted by professionals

QUICK START

Other products from Martindale:

G

16th Edition Testers

G

All-in-one’s

G

Calibration Equipment

G

Continuity Testers

G

Electrician’s kits

G

Full Calibration & Repair Service

G

Fuse Finders

G

Digital Clamp Meters

G

Digital Multimeters

G

Microwave Leakage Detectors

G

Motor Maintenance Equipment

G

Non-trip loop testers

G

Pat testers & Accessories

G

Phase rotation

G

Proving units

G

Socket Testers

G

Thermometers & Probes

G

Test Leads

G

Voltage Indicators

G

Specialist Metrohm testers (4 & 5kV)

G

Specialist Drummond testers

Martindale Electric Company Limited

Metrohm House, Penfold Trading Estate, Watford, WD24 4YY, UK.

Tel: +44(0)1923 441717  Fax: +44 (0)1923 446900

E-mail: [email protected]

Website: www.martindale-electric.co.uk

© Martindale Electric Company Ltd.  2005

Registered in England No. 3387451. Rev 8

Содержание VERITEST 2240

Страница 1: ...G Motor Maintenance Equipment G Non trip loop testers G Pat testers Accessories G Phase rotation G Proving units G Socket Testers G Thermometers Probes G Test Leads G Voltage Indicators G Specialist...

Страница 2: ......

Страница 3: ...ads 3 2 LOW continuity test 4 3 M insulation test 5 4 RCD test 6 5 Loop Zs IK 9 6 Non Trip Earth Loop Impedance Test Ra15mA 10 1 resolution with PFC calculation 7 Phase Rotation Sequence 11 8 Instrume...

Страница 4: ...rrent Equipment protected by Double Insulation Class II Caution refer to accompanying documents Caution risk of electric shock 10 OPTIONAL ACCESSORIES Infra red data lead VRTL1 Download software VRSOF...

Страница 5: ...219mA the instrument has a stored value for the resistance of the test leads current supplied by instrument during calibration procedure function selected FUNC GO NON TRIP EARTH LOOP TEST RA15MA Meas...

Страница 6: ...ds Use to adjust time up and down respectively At the end of the test if the resistance value is lower than 5 the instrument beeps twice indicating low resistance The resistance value is displayed on...

Страница 7: ...be adjusted from 10 999 seconds Adjust values using or This test can be used if a minimum measuring time is required UN I n FUNC L S UL M GO 100V 250V 500V 1000V Low resistance 5 seconds 10 seconds 10...

Страница 8: ...on display by O B Press the yellow key twice The instrument injects a current in phase with negative half wave of the voltage indicated on display by 180 FUNC UN I n L S S UL M GO GO 9 SPECIFICATION...

Страница 9: ...ct to the voltage Readings below 1 are displayed as 1 PLEASE NOTE MAN x5 and auto test modes are not available for RCD type A 500mA 8 INSTRUMENT CONNECTION TO PC OR A PRINTER The connection from the V...

Страница 10: ...st passed Please refer to the full user manual for tripping times Press to scroll through the test results RAMP The instrument generates a leakage current growing step by step in a given time interval...

Страница 11: ...Connect the mains plug to a 230V 50HZ socket outlet or to the appropriate conductor by means of the croc clips 4 Press key repeatedly to select P PE P PE is shown 5 Press the yellow key once The inst...

Страница 12: ...nt Icc UN Ra When UN phase to earth voltage 127V if 100V Vmeas 150V 230V if 150V Vmeas 265V This test is carried out at 15mA 10 UL M GO 7 PHASE ROTATION SEQUENCE 1 Connect red black and green test lea...

Отзывы: