         MPAAD User Manual  

 

HEAD IV 

Maintenance  

 

1.  

Deactivated device  

 

The  display  is  empty  and  whenever  the  left  or  right  button  is  pressed,  intentionally  or  by 
accident, the display indicates 

[ OFF ]

 . 

 
 

2.  

Device activation  

 

The  device  is  started  by  pressing  the  buttons  of  the  so-called  activation  sequence  several 
times. First release both buttons. Press the left button and keep it pressed 

( o )

.

 

After three 

seconds, the display will show number one 

[ 1   ]

. Press the right button 

( > ) 

three times in 

a  row  and  release  it.  After  each  pressing the display  will show  a  growing row  of  numbers 

[ 12    ]

[ 123  ]

 and 

[ 1234 ]

.

 

Once numeral 4 has appeared on the display, release the left 

control  button 

(  o  ).

  This  activation  sequence is  then  complete.  The whole sequence  must 

not  last  longer  than  ten  seconds.  If  a  mistake  is  made  the  whole  procedure  must  be 
repeated. 
 
The  display  shows 

[  ON  ]

  briefly  and then it images  the  remaining  capacity  of  the  battery 

ranging  from 

[  100%  ]

  to 

[  0%  ]

.  Subsequently,  automatic  calibration  takes  place  and 

[ CAL ] 

appears on the display

Afterwards, the machine switches to a stand-by mode. 

 

During the activation procedure, MPAAD checks the battery, chopping mechanism and 
electronics. 

 

3.  

Machine deactivation  

 
Turn  off  the  device  in  the  same  way  in  which  you  activated  it  –  i.e.  by  means  of  the 
activation sequence. The display shows 

[ OFF ]

. If you forget to turn the device off, it turns 

off  automatically  once  the  time of  the  stand-by  mode  has been fulfilled. The device can be 
turned off during the stand-by and jump modes. 
 

4.  

Calibration  

 
Calibration  is  carried  out  to  set  a  zero  height  for  the  landing  surface.  It  is  started  when 
activating the device and then automatically after each jump. When 

[ CAL ] 

appears on the 

display

  the  device  measures  a  current  pressure  and  sets  it  as  a  height  zero  value

.

  

Therefore,  you should always activate the device only in the area of the landing surface. If 
the  values  fluctuate  badly  during  the  measurement  of  pressure,  an  error  is  shown  on  the 
display. The device has to be deactivated.

 

PDF byl vytvo

ř

en zkušební verzí FinePrint pdfFactory 

www.fineprint.cz

Содержание MPAAD

Страница 1: ...MPAAD User Manual 1 User Manual Automatic Securing Device MPAAD 4th Edition In Jev ko in 10 2004 PDF byl vytvo en zku ebn verz FinePrint pdfFactory www fineprint cz...

Страница 2: ...3 User menu 4 Main parts 5 Location of the device HEAD III Technical data HEAD IV Contents 1 Deactivated device 2 Device activation 3 Device deactivation 4 Calibration 5 Stand by mode 6 Jump mode 7 Ad...

Страница 3: ...heck 3 Battery replacement 4 Chopping mechanism replacement 5 Device adjustment changes HEAD VII Service life and warranty conditions HEAD VIII Caution Placing the MPAAD securing device into a packing...

Страница 4: ...agnetic interferences MPAAD is a modern electronic micro processor controlled securing device that does not require any special maintenance and that features several additional functions The device ca...

Страница 5: ...tion takes place if the height above the ground is less than 270m and the fall rate is greater than 20 m s 1 The height lock is 450m TANDEM Activation takes place if the height above the ground is les...

Страница 6: ...The lower compartment contains a battery The middle compartment contains a pyrotechnic chopping mechanism The battery and the chopping mechanism can be replaced 5 Location of the device The device is...

Страница 7: ...evel AGL Activation height m 270 m Expert 270 m Beginner 560 m Tandem Activation rate m s 35 m s 1 Expert 20 m s 1 Beginner 35 m s 1 Tandem Height lock m 450 m Expert 450 m Beginner 900 m Tandem Accur...

Страница 8: ...0 Subsequently automatic calibration takes place and CAL appears on the display Afterwards the machine switches to a stand by mode During the activation procedure MPAAD checks the battery chopping mec...

Страница 9: ...djustment is indicated by letter b for instance 14 00b When the EXPERT adjustment is used the far right display field is empty 6 Jump mode Just a while after an airplane s start the device automatical...

Страница 10: ...nu beginning 01 888o opening height during the last jump 02 888J total number of jumps 03 88 remaining battery capacity in percents 04 3 65v battery voltage in volts 05 888d battery age in days 06 41b...

Страница 11: ...ounting of a MPAAD device into a parachute system HEAD VI Maintenance 1 Special maintenance The device does not require any special maintenance The device performs continual automatic checks battery i...

Страница 12: ...connectors should be limited only to the necessary replacement of the battery Unnecessary repeated disconnecting may result in the deterioration of the electrical parameters of the connectors Battery...

Страница 13: ...osely squashed flat so that the use of this side of the spanner for the screw tightening would be avoided Note Valid for the product dispatched from 08 2004 Check the device by turning it on 4 Choppin...

Страница 14: ...o cartridge into the counterpart piece placed in the upper left part of the device body Place the pyro cartridge into the central part of the device so that its whole height sinks in the groove PDF by...

Страница 15: ...ition The surface under the conductor is provided with glued on elastic rubber to insulate the cable Once the pyro cartridge has been replaced check the operation of the device by turning it on PDF by...

Страница 16: ...the parachute airplane must not descend below the height of the landing ground If the positive re calibration of the landing ground is applied the airplane must not descend below the height of the la...

Страница 17: ...a primary means for parachute opening The different use of the MPAAD device than is described in the operation manual may lead to its wrong function Considering a certain risk level that is an integra...

Страница 18: ...MPAAD User Manual 18 Pilot parachute PV 038 The size of the device is 100 x 62 x 20 mm PDF byl vytvo en zku ebn verz FinePrint pdfFactory www fineprint cz...

Страница 19: ...4 5 the cord creates the surface with which the pad aligns onto the body of the pyro cartridge Completing The device must be completed by an authorized person First insert the cord and the pad into th...

Страница 20: ...tion date __________________________________________________________ Reserve parachute type and size _____________________________________________ Production date _____________________________________...

Страница 21: ...______________________________ Estimated activation height ________________________________________________ Air temperature on the ground ______________________________________________ How much time d...

Страница 22: ...MPAAD User Manual 22 ________________________________________________________________________ PDF byl vytvo en zku ebn verz FinePrint pdfFactory www fineprint cz...

Отзывы: