MPAAD User Manual
10
After planned landing on the landing ground outside an airport using the re-calibration of
the landing ground height, the device turns off automatically! The display is empty and
when pressing on the button the
[ OFF ]
sign becomes displayed
.
Prior to the next jump,
be it on the original or a new landing ground, turn on the device again.
8.
User Menu
To enter the User Menu press the right button
( > )
and keep it pressed for about 4 seconds.
The display will show
[ -01- ].
Release the button and the display will show the height of
opening. If you keep on pressing the button, you will start going through the menu. Press
the left button
( o )
to leave the menu. After a while the menu will deactivate itself.
Menu beginning
[ -01- ]
[ 888o ]
opening height during the last jump
[ -02- ]
[ 888J ]
total number of jumps
[ -03- ]
[ 88% ]
remaining battery capacity in percents
[ -04- ]
[ 3.65v ]
battery voltage in volts
[ -05- ]
[ 888d ]
battery age in days
[ -06- ]
[ 41b8 ]
device manufacturing number
[ -07- ]
[ 01.00 ]
controlling firmware version
Menu end
9.
Error statuses
If
[ E
xxx
]
(error) appears on the display during automatic control or at any time, it is
necessary to replace either the battery or the chopping mechanism, or to restart the device.
If
[ F
xx
]
(failure) appears on the display, the device must be sent to the manufacturer for
inspection. In this case the device becomes blocked and cannot be turned off.
E001, E010
Range error during calibration. The scatter of pressure samples is too large.
E002, E020
Chopping mechanism error. Pyro cartridge is faulty or activated.
E004, E040
Battery error. Battery voltage is low.