General Vent Installation Information
This gas appliance is approved to be vented either through the side wall or vertically through the roof. Only Kingsman Flex(Z-
Flex)Venting Kits and components specifically approved and LABELED for this stove may be used. This appliance is also
approved for use with Simpson-Duravent Direct Vent system, Ameri-Vent Direct Vent Pipe System, ICC Excel Direct, Metal Fab Sure-
Seal DV and Selkirk Direct Temp.
RIGID OR HARD PIPE
When using Simpson Duravent, AmeriVent pipe, ICC Excel Direct, Metal Fab Sure-Seal DV and or Selkirk Direct Temp a Duravent hard-
pipe adapter must be used (part # ZDVDFA for fireplaces and part # ZDVDKA for Stoves, Serenity and ZDV3624B). Follow installa-
tion instructions provided by Simpson Duravent/AmeriVent/Selkirk Direct Temp, ICC Excel Direct, Metal Fab Sure-Seal DV for installation
of pipe and adhere to the clearance to combustibles provided in this manual. Apply a bead of Mill Pac high temp sealant to all joints of
pipes, adapters and termination, when using Kingsman Flex(Z-Flex)Venting venting and Simpson Duravent venting.
NOTE: Increase framing depth by one inch when using hardpipe.
WARNING: DO NOT mix parts from different systems unless stated in the manual.
Flex Pipe Venting
Flex pipe is shipped in unexpanded length. When installing pipe expand the lengths. Pipe can be expanded to twice their lengths e.g. 4ft.
to 8ft. Fully extend pipe and cut off remaining pipe.
Do not use more than 2 couplers to extend short pipes. Single sections are preferred in an installation attaching at the fireplace and ter-
mination.
Place the spring spaces provided approximately every two feet to stabilize 4” flex in the center of 7” flex. When forming bends place
spring in bend or before and after. (See Fig. 1).
Horizontal runs require support metal straps every 2 feet. In off set installation support straps should be used to stabilize pipe.
Expand 4” and 7” flex pipe to the point that the 7” protrudes approximately 2 to 3 inches past outer wall and the 4” flex protrudes approxi-
mately 2 to 3 inches past the 7” flex. See Fig. 1. Attach the 4” pipe to the termination first and secure with sealant and four screws then
attach the 7” flex to the termination with caulking and four screws. Termination may then be moved back to the outer wall and attached to
home screwing into the framing. Silicone around termination to waterproof. If siding shield is going to be used attach this using same
attaching hole as the top of termination after termination has been caulked for water proofing.
Use Hi Temp Sealant
Apply a bead of mill pac high temp sealant to all joints and use four screws to secure each pipe at fireplace, termination and any joint if
joining any sections of pipe.
NOTE: It is critical to the proper and safe
operation of this fireplace that on all con-
nections the inner liner and the outer cas-
ing are both caulked with liberal amounts
of sealant. Do not use any kind of tape or
silicone other than that recommended in
this manual. Mill Pac Sealant
WARNING:
WHEN THE HORIZONTAL VENT TERMINATION IS ACCESSIBLE A CERTIFIED GUARD
(SAFETY CAGE) SHALL BE INSTALLED.
60