Kingsman Fireplace Venting

Catalog
Number

Description

ZDVHSK

Horizontal Vent Starter Kit - 3 FT Length

Horizontal Vent Termination, Wall Thimble,

36” Flex Pipe, Mill Pac, screws/washers, springs.

ZDVHSK5

Horizontal Vent Starter Kit - 5 FT Length

Horizontal Vent Termination, Wall Thimble,

60” Flex Pipe, Mill Pac, screws/washers, springs.

FDVVT40

Vertical Vent Termination converts from  15’-40’ 

to 15’ and under 

FDVHT

Horizontal Vent Termination

FDVHSQ

Horizontal Square Termination

ZDVST

Horizontal Snorkel Termination

(34” Tall, 24” Center to Center)

FDVHSC

Safety Cage for Horizontal Termination

ZDVAIS

Attic Insulation Shield

ZDVVOS

Offset Support

ZDVFS

Firestop Spacer

ZDVRS

Roof Support

ZDVWT

Wall Thimble (Horizontal Venting)

ZDVSSLR

Siding Shield - Large Return

MDV38IS

Insulation Sleeve for Low Enclosure

ZDV48GP

Galvanized Pipe 7” Dia. x 48” 

(Vertical Installations)

ZDVAAF

Flashing 7” c/w Storm Collar (1/12 to 7/12)

ZDVAF2

Flashing 7” c/w Storm Collar (8/12 to 12/12)

ZDVAF3

Flashing 7” c/w Storm Collar Flat

ZDV7SC

Storm Collar 7”

ZDVFK5

Flex Kit (4” & 7” Dia.) x 2.5’ (Unexpanded) 5’ 

Expanded

ZDVFK8

Flex Kit (4” & 7” Dia.) x 4’ (Unexpanded) 8’ 

Expanded

ZDVFK20

Flex Kit (4” & 7” Dia.) x 10’ (Unexpanded) 20’ 

Expanded

*Kits are complete with spring stand-offs, silicone.

ZDV4FC

Flex Connector 4” Diameter

ZDV7FC

Flex Connector 7” Diameter

ZDV4SS

Spring 4” Standoff Spacer

ZDVDFA

Simpson Dura-Vent Fireplace Adapter

(for ZDV33/36/42/47, ZDV6000, MDV31 & 

HB models)

ZDVHSKSQ

Horizontal Square Termination Vent Starter 
Kit - 3 FT Length

Horizontal Vent Termination, Wall Thimble,

Wall Thimble, 36” Flex Pipe, Mill Pac

ZDVHSKSQ5

Horizontal Square Termination Vent Starter 
Kit - 5 FT Length

Horizontal Vent Termination, Wall Thimble,

Wall Thimble, 60” Flex Pipe, Mill Pac

FDVHSQ

Horizontal Square Vent Termination

Electronic Ignition Replacement Parts IPI

1002-P001si

Valve IPI (NG; ON/OFF)

1002-P002si

Valve IPI (LP; ON/OFF)

1006-P002si

Valve IPI (NG; Hi/Lo)

1006-P603si

Valve IPI (LP; Hi/Lo)

1002-P047si

Pilot Assembly (LP)

1002-P033si

Pilot Assembly (NG)

1002-P089si

Spark Electrode (Long)

1002-P113si

Electrode Flame Sensor (Long)

1002-P302si

IPI Ignition Board

1002-P850si

AC Wall Adapter

1002-P12BH

Battery Pack

1002-P912si

Wiring Harness

1002-P166si

Orifice Pilot (NG #62)

1002-P168si

Orifice Pilot (LP #35)

1002-P013si

Stepper Motor (NG)

1002-P012si

Stepper Motor (LP)

1002-P016is

Hi/Lo Regulator (NG)

1002-P014si

Hi/Lo Regulator (LP)

Miscellaneous Parts

1000-150GE

#Silicone GE RED IS806 #736

1000-150MP

#Hi-Temp Mill Pac Sealant 840099

1000-214

#Piezo Igniter 1244-17 MARK 21

1000-215

#Pal Nut (18MMXI.5MM)BLK (1364.03)

1000-218

#Switch Ivory (1451/001)

1000-227

#Cover Ivory (86001/001)

1000-255

#Orifice Brass - (State Size)

1000-EMBER

#Moon Rock

2000-080

#Thermodisc 2450 (For Blower)

2000-081

#Blower Motor QLN65/2400

1000-085

#Control Variable Speed KBWC-13BV

1000-306

Thermalcord - Adhesive Back for Door Frame

47HB-311

Tempered Low E Glass - for model 

HBZDV4740 model and MQHBZDV4736

36HB-123

Upper Door Spring

Conversion Kit  (Sit Valve Only)

4740HB-CKLP

LP Conversion Kit for HBZDV4740, 

MQHBZDV4736 (Millivolt)

4740HB-CKNG

NG Conversion Kit for HBZDV4740, 

MQHBZDV4736 (Millivolt)

4740HB-CKLPI

LP Conversion Kit for HBZDV4740,

MQHBZDV4736 (IPI)

4740HB-CKNGI

NG Conversion Kit for HBZDV4740,

MQHBZDV4736 (IPI)

25

Содержание MQHBZDV3636

Страница 1: ...NCE VENTED GAS FIREPLACE A Division of R Co Inc 2340 Logan Avenue Winnipeg Manitoba Canada R2R 2V3 Ph 204 632 1962 Printed in Canada October 21 2014 Part 36MQ MAN14 INSTALLER Leave this manual with the appliance CONSUMER Retain this manual for future reference For Propane Horizontal installations the venting must be a minimum of one foot vertical off the flue before going horizontal This appliance...

Страница 2: ...used with the installations e g marble tile and the adhesives used to adhere this product to the walls can react with heat and cause odours It is recommended that you burn your gas fireplace or stove for a minimum of four hours at a time with the fan off after the curing of the paint has been completed These odours can last upward to 40 hours of burn time keep burning at a minimum of four hours pe...

Страница 3: ... Mantels Surrounds 26 27 Dimensions Installations of Wall Mount Surrounds 28 Fan Installation 29 Split Receptacle Fan Speed Control Outside of Fireplace 30 Installing MQRB4236 Liner Panels 31 Brick Installation 32 Installation of HB Porcelain Liners HB36PL HB42PL HB47PL 33 Gas Line Installation 34 Millivolt System Lighting and Burner Control 35 Trouble Shooting The Gas Control System 36 Burner Sys...

Страница 4: ... until unit is COMPLETELY cool before touching glass or attempting to install or remove Child Safety Screens To install screens hook bottom clip onto glass door frame then press down and push upper clip under top glass door frame then release Clip will hook onto frame To remove Safety Screens WAIT UNTIL FIREPLACE IS COMPLETELY COOL Press down on upper clips and remove screen from fireplace glass d...

Страница 5: ...ALLED IN MANUFACTURED MOBILE HOMES IN CANADA Please follow the current ANSI NFPA 70 National Electrical Code in the USA and CAN CSA C22 1 Canadian National Electrical Code in Canada An appliance must be grounded to the steel chassis of the home with 8 ga copper wire using a serrated or star washer to penetrate paint or protective coating to insure grounding Use carriage bolt at the attachment poin...

Страница 6: ...nce 15 Installation and repair should be done by a qualified service person The appliance should be inspected before use and at least annually by a professional service person More frequent cleaning may be required due to excessive lint from carpeting bedding material et cetera It is imperative that control compartments burners and circulating air passageways of the appliance be kept clean Make su...

Страница 7: ... in the living area outside the bedroom s The carbon monoxide detector shall comply with NFPA 720 B A carbon monoxide detector shall be located in the room that houses the appliance or equipment and shall Be powered by the same electrical circuit as the appliance or equipment such that only one service switch services both the appliance and the carbon monoxide detector Have battery back up power M...

Страница 8: ... on Wall Corner F Exterior Wall See Mantel Leg Clearances Instruction for the proper placement of fireplace Island installation with a top vent is possible as long as the horizontal portion of the vent system does not exceed 20 feet 6 1 m Fireplace Dimensions HBZDV36 HBZDV36 CVCK Non Combustible Header Attached 8 ...

Страница 9: ...ore the elbow on any horizontal runs of one foot or greater This allows for cleaner combustion and greatly reduces carboning and cleaning of glass MQHBZDV3636 Framing for your Gas Fireplace MQHBZDV36 Louvered MQHBZDV36 WITH HB36CVCK CLEAN VIEW CIRCULATING KIT 4 When installing horizontal with a 90 degree bend maintain a mini mum of two and a half 2 5 inches above the bend in enclo sures 5 For a fi...

Страница 10: ...W CIRCULATING KIT HB36CVCK WITH MQHB36SW SURROUND HBZDV36 Framing and Facing Requirements Non Combustible Header Attached AA Non Combustible Header Attached AA AA AA Non Combustible Header Attached AA Non Combustible Header AA AA 10 ...

Страница 11: ...stibles Back from Standoffs 0 inches 0 mm Side from standoffs 0 inches 0 mm Floor 0 inches 0 mm Ceiling from bottom of fireplace 60 inches 150 cm Top from standoffs 0 inches 0 mm Top of 90 degree bend in Minimum Enclosure of 42 to 43 inches 3 1 2 inches 89 mm All Vent Systems Top of 90 degree bend in Enclosure over 43 inches 2 1 2 inches 64 mm All Vent Systems Top of Horizontal Pipe 1 1 2 inches 3...

Страница 12: ...System MQHBZDV3636N MQHB36SWCVPW Surround Convex Pewter Coverage 41 H x 40 1 2 W 3636MQ BLPSI Burner Assembly Liquid Propane c w Valve ACCESSORIES System MQHBZDV3636LP Fireplace Surrounds Trims Conversion Kit Sit Valve Only HB36SAB Surround Antique Brass Coverage 35 1 2 H x 41 1 8 W 3632HB CKLP LP Conversion Kit for HBZDV3632 3636 Millivolt 3632HB CKNG NG Conversion Kit for HBZDV3632 3636 Millivol...

Страница 13: ...3 36 42 47 ZDV6000 MDV31 HB models ZDVHSKSQ Horizontal Square Termination Vent Starter Kit 3 FT Length Horizontal Vent Termination Wall Thimble Wall Thimble 36 Flex Pipe Mill Pac ZDVHSKSQ5 Horizontal Square Termination Vent Starter Kit 5 FT Length Horizontal Vent Termination Wall Thimble Wall Thimble 60 Flex Pipe Mill Pac FDVHSQ Horizontal Square Vent Termination Electronic Ignition Replacement Pa...

Страница 14: ... on Wall Corner F Exterior Wall See Mantel Leg Clearances Instruction for the proper placement of fireplace Island installation with a top vent is possible as long as the horizontal portion of the vent system does not exceed 20 feet 6 1 m Fireplace Dimensions HBZDV42 HBZDV42 CVCK Non Combustible Header Attached 14 ...

Страница 15: ...m of two and a half 2 5 inches above the bend in enclosures 5 For a fireplace with louvers combustible floor can raise 1 above the bottom of the fireplace For a fireplace with HB42CVCK Clean view Circulating Kit floor or hearth can raise 7 above the bottom of the fireplace with portions being combustible and non combustible See drawing on following page 6 When installing MQHB42SW surround the fire...

Страница 16: ...EAN VIEW CIRCULATING KIT HB42CVCK WITH MQHB42SW SURROUND Note A HBCVCK must be used when installing a MQHBSW Wall Surround HB42 Framing and Facing Requirements Non Combustible Header Attached Non Combustible Header Attached 16 ...

Страница 17: ...Combustibles Back from Standoffs 0 inches 0 mm Side from standoffs 0 inches 0 mm Floor 0 inches 0 mm Ceiling from bottom of fireplace 60 inches 150 cm Top from standoffs 0 inches 0 mm Top of 90 degree bend in Minimum Enclosure of 45 to 46 inches 5 inches 128 mm All Vent Systems Top of 90 degree bend in Enclosure over 46 inches 2 1 2 inches 64 mm All Vent Systems Top of Horizontal Pipe 1 1 2 inches...

Страница 18: ...age 37 3 8 H x 43 3 8 W HB42SLBL Surround Slim Line Gun Metal Black Coverage 37 3 8 H x 43 3 8 W Designer Doors for 42 Fireplaces Operative HB42DDA1BL Designer Door Arch Series 1 Black HB42DDTA1A Trim Antique for Designer Arch Series 1 HB42DDTA1C Trim Chrome for Designer Arch Series 1 HB42DDTA1P Trim Polish Brass for Designer Arch Series 1 HB42DDS1BL Designer Door Straight Series 1 Black HB42DDTS1...

Страница 19: ...one GE Red IS806 736 1000 150MP Hi Temp Mill Pac Sealant 840099 1000 214 Piezo Igniter 1244 17 MARK 21 1000 215 Pal Nut 18MMXI 5MM BLK 1364 03 1000 218 Switch Ivory 1451 001 1000 227 Cover Ivory 86001 001 1000 255 Orifice Brass State Size 1000 EMBER Moon Rock 2000 080 Thermodisc 2450 For Blower 2000 081 Blower Motor QLN65 2400 1000 085 Control Variable Speed KBWC 13BV 1000 306 Thermalcord Adhesive...

Страница 20: ... on Wall Corner F Exterior Wall See Mantel Leg Clearances Instruction for the proper placement of fireplace Island installation with a top vent is possible as long as the horizontal portion of the vent system does not exceed 20 feet 6 1 m Fireplace Dimensions HBZDV47 HBZDV47 CVCK Non Combustible Header Attached 20 ...

Страница 21: ...insulation sleeve is not required 5 For a fireplace with louvers combustible floor can raise 1 above the bottom of the fireplace For a fireplace with HB47CVCK Clean view Circulating Kit floor or hearth can raise 7 above the bottom of the fireplace with portions being combustible and non combustible See drawing on following page 6 When installing MQHB47SWCC wall surround the fireplace must be raise...

Страница 22: ...Non Combustible Header Attached Non Combustible Header Attached Non Combustible Header Attached Non Combustible Header Attached 22 ...

Страница 23: ...ffs 0 inches 0 mm Floor 0 inches 0 mm Ceiling from bottom of fireplace 60 inches 150 cm Top from standoffs 0 inches 0 mm Top of 90 degree bend in Minimum with insulation sleeve Enclosure of 50 1 2 to 56 1 2 inches 2 1 2 inches 64 mm All Vent Systems Top of 90 degree bend in without insulation sleeve Enclosure over 56 1 2 to 60 inches 4 1 2 inches 114 75 mm All Vent Systems Top of 90 degree bend in...

Страница 24: ...ass Coverage 42 5 8 H x 50 1 8 W HB47SLAB Surround Slim Line Antique Brass Coverage 42 3 8 H x 48 3 8 W HB47SLCR Surround Slim Line Chrome Coverage 42 3 8 H x 48 3 8 W HB47SLPB Surround Slim Line Polish Brass Coverage 42 3 8 H x 48 3 8 W HB47SLBL Surround Slim Line Gun Metal Black Coverage 42 3 8 H x 48 3 8 W Designer Doors for 47 Fireplaces Operative HB47DDA1BL Designer Door Arch Series 1 Black H...

Страница 25: ...ination Wall Thimble Wall Thimble 36 Flex Pipe Mill Pac ZDVHSKSQ5 Horizontal Square Termination Vent Starter Kit 5 FT Length Horizontal Vent Termination Wall Thimble Wall Thimble 60 Flex Pipe Mill Pac FDVHSQ Horizontal Square Vent Termination Electronic Ignition Replacement Parts IPI 1002 P001si Valve IPI NG ON OFF 1002 P002si Valve IPI LP ON OFF 1006 P002si Valve IPI NG Hi Lo 1006 P603si Valve IP...

Страница 26: ... the minimum height and width requirements for a combustible mantel Note For the installation of the MQHBSW Maintain Minimum 1 Clearance to Top Sides of the surround Combustible or non combustible materials can be placed up to 1 of the sides and top of surround but not extending to or over the face of surround Caution The CVCK must be flush with the wall 26 ...

Страница 27: ...or over the front face of the fireplace NO PORTION OF GRILL AREA OR DOOR AREAS CAN BE COVERED except where designer clean view kit is used Combustible material can extend flush to unit up to the top bottom and sides of fireplace to stand offs For COMBUSTIBLE materials extending in front of fireplace consult Mantel and Mantel Leg Drawings Surrounds If installing wide or slim line surrounds the fini...

Страница 28: ...e mounting holes on the Lower Tab with the holes on the CVCK Side Frame Using the previously removed screws in Step 1 secure the Lower Tab to the CVCK side frame Replace the old CAP with the new CAP that accompanied the Modern Surround kit Check Installation to make sure the Surround and CVCK is secure Concave A B C D E F G H I J L HB36 40 1 2 49 1 2 32 1 2 21 5 8 9 1 2 9 1 2 8 1 2 2 1 2 5 1 2 32 ...

Страница 29: ... set screw on the side of vari able speed controller to increase or decrease the minimum fan speed lowering minimum fan speed will decrease sound level created by fan Reinstall switch into wall mount and cover with face plate Parts List 1 ea fan comes with 4 ft cord Two 14 leads female ends 1 ea variable speed control wall mount type 1 ea thermodisc 1 thermodisc mount assembly Electrical Services ...

Страница 30: ... pronged grounding plug for your protection against shock hazard and should be plugged directly into a properly grounded three prong receptacle Label all wires prior to disconnection when servicing controls Wiring errors can cause improper and dangerous operation Verify proper operation and servicing Caution Electrical installation to be done by a qualified installer All wires must be connected an...

Страница 31: ... Remove 2 DT Screws from Firebox sides Do not discard these screws Place Side Panels into Firebox as shown in Ref 3 below tilt and slide into place Replace and tighten DT Screw through hole in top of Side Panel and into side of Firebox 2 Install Back Panel Be sure Flange is facing outward as per Ref 1 Engage Slots into Locking Tabs in Firebox Top as shown See Ref 2 above Slide Back Panel into plac...

Страница 32: ...Place optional front bridge ledge 3 in the area front of false bottom 5 Place rear Brick Panel 4 up against the rear of Firebox by tilting top of panel towards you and sliding bot tom of Panel over the back of burner system 6 Loosen screws holding brick clip in position Rotate clip up out of the way and slide side brick 5 up against rear Brick Side brick must be flush with side wall of Firebox Rot...

Страница 33: ...ck Clip out of the way and slide Side Panel up against Back Panel Side Panel tabs should engage top and bottom of Back Panel See Ref 3 Rotate Brick Clip down over Side Panel and tighten screw 5 Re install Log Holder and Brick Filler Panel if applicable removed in step 2 Install Log Set as per instruction and re install Door Note Warping and Discoloration of Porcelain or Painted Metal Liners Is Not...

Страница 34: ... pressures in excess of 1 2 PSIG 3 5 KPa 9 The appliance must be isolated from the gas supply piping system by closing its individual shutoff valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1 2 PSIG 3 5 KPa Note The gas line connection may be made of 1 2 rigid pipe or an approved flex connector Since some municipalities have additional loca...

Страница 35: ...way and hold it With the other hand push in the red ignitor button until you hear a click Now observe closely the pilot burner located on the rear center left hand side of the main burner If a flame has appeared then continue to depress the control knob for 20 seconds If the flame did not appear then continue to depress the red ignitor button every 5 seconds until a flame is established NOTE If af...

Страница 36: ...witch If okay jumper wires across wall switch wires at valve If burner comes on wires are faulty or connections are bad Generator may not be Check generator with millivolt meter Take reading at gen generating sufficient voltage erator terminals of gas valve Should read 325 millivolts minimum while holding valve knob depressed in pilot posi tion and wall switch off Replace faulty generator if read ...

Страница 37: ...ving Burner System 1 Disconnect gas line connection at burner system through access cover opening CAUTION ALL WORK SHOULD BE PERFORMED BY A QUALI FIED AND CERTIFIED TECHNICIAN 2 Remove extension knobs and wiring from face of gas valve 3 Remove false bottom Undo screws holding back log holder and remove Remove screws from perimeter of burner system pan lift pan at one back corner and rotate pan up ...

Страница 38: ...xercise caution when working within the area ALL WORK SHOULD BE PERFORMED BY A QUALIFIED AND CERTIFIED TECHNICIAN Monthly Flame Inspection It is recommended to turn on the unit at least once a month and inspect the flame pattern to ensure there are no problems with the burner tube The pilot flame should also be inspected monthly to ensure proper operation MQHBZDV3636 MQHBZDV4236 MQHBZDV4736 Flame ...

Страница 39: ... For MQRB4236LPT LP Conversion Millivolt 1001 P167SI 30 977 167 53 1000 P201VE Hex 1 4 1001 P201SI 0 907 201 4236RBT CKLPI For MQRB4236LPTE LP Conversion IPI 1001 P168SI 35 977 168 53 1000 P201VE Hex 1 4 1002 P016SI 0 907 016 NOTE The MQRB4236N CANNOT BE CONVERTED TO LP If the MQRB4236NT you wish to convert to LP has a serial number less than 4708 You MUST order the 4236RB SRKP upgrade kit See Gas...

Страница 40: ...egulator by following instructions supplied with conversion kit also See Parts B C 5 Adjust the primary air setting to the correct setting as specified in the manual or label plate To adjust air setting loosen screw on the side of air mixing tube and rotate to the correct opening using a drill bit or tape measure Retighten screw 6 Reinstall false bottom and burner by reversing steps 1 2 Pilot Shie...

Страница 41: ...he new injector is proper for the application The injector size is stamped on the side of the injector near the top LPG injectors have a groove machined around their circumference near the top while NG injectors do not have a groove e Refer to the Appliance Manufacturers instruction sheet for the proper injector size 6 Insert the Allen wrench into the end of the injector Then insert into injector ...

Страница 42: ...Gas Conversion for Modulator PART C WARNING WARNING 42 ...

Страница 43: ... the remote Contrary to this feature is a Manual HI LO Control Knob The Modulating Servo Motor requires the Remote system to be present Backup Battery Pack This component permits the IPI system to operate without the need for an external AC Adapter power source The advantage to using the battery backup is that in the case of a power failure the appliance is still operable Remote Receiver This comp...

Страница 44: ...rol wiring harness instead of the main IPI harness From the Remote wiring harness use its male plug in connector and connect it to the female plug in in the main IPI harness Now the circuit is complete So the way it works is that electri cal power is supplied to the Remote Receiver module and then pro ceeds to the Main IPI module Furthermore note that a Backup Battery Pack is not required in this ...

Страница 45: ...Configuration 1 Basic manual HI LO and manual ON OFF capabilities 45 ...

Страница 46: ...manual HI LO capabilities OPTIONAL For units with remote HI LO capabilities a modulating servo is required to be installed on the valve The connectors to this servo must be connected to the Remote Harness as shown in the figure above 46 ...

Страница 47: ...Configuration 3 Remote ON OFF variable HI LO and fan capabilities Refer to the fan installation removal section for fan installation 47 ...

Страница 48: ...ment LIGHTING INSTRUCTIONS 1 STOP Read the above safety information on this label 2 Remove batteries from Receiver and or Battery Backup Pack 3 Turn off all electric power to the fireplace 4 This fireplace is equipped with an ignition device which automatically lights the pilot Do not try to light the pilot by hand 5 Open the glass door 6 Turn manual shutoff valve clockwise to OFF position located...

Страница 49: ...igh heat silicone tempera ture resistant to 500 F 260 C apply a con tinuous bead of approximately 1 32 to all four sides of frame and insert glass with new gas ket Frame should be on flat surface with a small amount of weight pressing glass into silicone Let dry approximately 15 to 20 min utes The door can be re installed by revers ing Steps 1 2 Use caution when removing broken glass wear gloves R...

Страница 50: ...f log 6 Place onto the mounting tab on log 2 Locate the 2 holes on the bottom of log 7 Place onto mounting tabs on log 5 STEP 5 Place glowing embers on the front of the burner tube and ember plates Place lava rock and vermiculite on the burner pan as shown DO NOT PLACE LAVA ROCK AND VERMICULITE ON BURNER TUBE WARNING Failure to position the parts in accordance with these diagrams or failure to use...

Страница 51: ...EP 3 Using the platform mount access holes attach the rock platform as shown STEP 4 Fill around the rock platform with lava rock Do not place any lava rock on the burner Sprinkle vermiculite over top of the lava rock Glass or Silicon Sand Lava Rock Shown WARNING Failure to position the parts in accordance with these diagrams or failure to use only parts specifically approved with this appliance ma...

Страница 52: ...ks 3 onto the burner as shown STEP 7 Place rocks 4 onto the burner as shown STEP 8 Place rocks 6 onto the burner as shown STEP 9 Place remaining rocks 4 and 6 into position as shown Finished Rock F2 Setup Placement of rocks for steps 8 and 9 can be random Do not place any of the rocks directly over the burner tubes 52 ...

Страница 53: ...ount access holes attach the rock platform as shown STEP 3 Fill around the rock platform with lava rock Sprinkle vermiculite over top of the lava rock Do not place lava rock or vermiculite on top of the burner tube STEP 4 Place rocks 1 onto the burner as shown Do not place rocks directly onto the burner tubes Glass or Silicon Sand Lava Rock Shown WARNING Failure to position the parts in accordance...

Страница 54: ... shown Do not place rocks directly onto the burner tubes STEP 6 Place rocks 4 into position as shown STEP 7 Place rocks 6 into position as shown STEP 8 Place remaining rocks 4 and 6 into position as shown Note If flame impingement on the rocks causes sooting you may have to move or remove one or more rocks Do not place rocks directly over top of the burner tube 54 ...

Страница 55: ...hen placing glass embers near the pilot area so as not block or have the glass fall over the crossover holes from the pilot to the burner as delayed ignition can occur The following types of glass are approved Ember Glass Material from American Fireglass Maximum amount Natural Gas is 5 lbs Propane units 5 lbs Liquid Glass from Firegear Maximum amount Natural gas is 5 lbs not recommended for Propan...

Страница 56: ...y Embers may be used with or without other accessories ULK2 UNIVERSAL LIGHT KIT Optional Accent Lighting Kit See separate installation page NOTE Pilot Area Must Not Be Covered as delayed ignition can occur Do Not Cover any part of the burner tube with rocks or logs as sooting may occur In some positions Logs can cause flame pattern to roll backward causing sooting If this occurs re position Logs B...

Страница 57: ...rt lamp wires through access hole in firebox as above Apply new sealant Mill Pac Secure Lamp Plate with screws Please follow the current ANSI NFPA 70 National Electrical Code in the USA and CAN CSA C22 1 Canadian National Electrical Code in Canada Contents of Kit 2 12V Halogen Lamps Lamp Plate with Insulated Studs wiring 12VAC Transformer with 3 prong plug wire connectors Light Switch Cover Plate ...

Страница 58: ...d facing upward or sideways Replace burner tube and false bottom along with pilot shield STEP 4 Connect switch wires between lamp wire and transformer see schematic Connect remaining lamp wire to transformer Transformer can then be plugged in and the housing fastened to the bottom of the fireplace Glass may be used to cover perforations in false bottom Screw Screw Screw Screw 58 ...

Страница 59: ...TE Clearances are to the edge of terminal plate add 6 3 4 to clearances to arrive at center line NOTE Local Codes or Regulations may require different clearances Termination It is imperative that the vent termination be located observing the minimum clearances as shown There must not be any obstruc tion such as bushes garden sheds fences decks or utility build ings within 24 from the front of the ...

Страница 60: ...uplers to extend short pipes Single sections are preferred in an installation attaching at the fireplace and ter mination Place the spring spaces provided approximately every two feet to stabilize 4 flex in the center of 7 flex When forming bends place spring in bend or before and after See Fig 1 Horizontal runs require support metal straps every 2 feet In off set installation support straps shoul...

Страница 61: ... and the number of bends required 2 Having determined the vertical distance determine the maxi mum horizontal section allowed 3 Vent table has been established for 90 horizontal vertical runs With use of flex pipe distance not having 90 bends will not fall into vent table standards See Fig B Horizontal Venting Table From Bottom of Fireplace for venting to a maximum of 40 ft 12 2 meters Total Verti...

Страница 62: ... the 4 flex pipe as required Then attach the seven inch 7 pipe by the same method 8 Support horizontal pipes every two 2 feet 61 cm with metal strap bands Re check fireplace to make sure it is levelled and properly posi tioned and secured 9 Support vertical pipes to maintain a minimum of 1 or greater clear ance to combustibles with metal strapping bands 10 If finishing the outside wall with vinyl ...

Страница 63: ...d two rulers or by using a roof pitch card See figure below Slide a Roof Flashing suitable to your roof slope over the vent Place the edge of the flashing plate that will be on the higher part of the roof slope under the shingles Both the sides and the lower edge lay on top of the shingles NOTE At the top edge of the flashing plate lift the shingles and nail the plate to the roof deck then cement ...

Страница 64: ...oddlers young children and other at risk individuals out of the room and away from hot surfaces Do not leave the fireplace remote control where it is accessible to children Termination Cap Safety All Units WARNING WHEN THE HORIZONTAL VENT TERMINATION IS ACCESSIBLE A CERTIFIED GUARD SAFETY CAGE SHALL BE INSTALLED SAFETY CAGES ARE AVAILABLE FOR ALL HORIZONTAL VENT TERMINATIONS CHECK WITH YOUR DEALER...

Страница 65: ...UIPPPED WITH INTERMITTENT PILOT IGNITION Downward vertical vent runs are permitted however Cold Climate Switch Standing Pilot Mode must not be used Refer to your appliance manual for Minimum Vertical Rise before First 90 elbow Measured from bottom of appliance to center of vent pipe to avoid overheating of vent pipe Refer to PVH58 Manual for proper installation and use PVH 58 Maximum Minimum Vent ...

Страница 66: ...s 4 6 5 8 venting to 5 8 For Power Vent installations where flex pipe will be used up to the Power Vent unit Z47PVA Pipe Reducer 8 Sm 7 Sm Pipe Reducer 5 Sm 4 Sm Adapts PVH58 to accept 4 7 Flex Pipe One 12 section of hard pipe must be connected directly to the Power Vent before any adapters are connected Order the appropriate lengths of venting see below ZDVFK5 Flex Kit 4 7 Dia x 2 5 Unexpanded 5 ...

Страница 67: ... other than in a normal residential environment c damages caused by any unauthorized alteration or repair of the unit affecting its stability or performance d damages caused by improper matching or application of the unit or the unit s components e damages caused by failing to provide proper maintenance and service to the unit f any expenses incurred for erecting disconnecting or dismantling the u...

Отзывы: