Problems during the "CLEAN TEST"
12
-
During Phase 3 the water reaches
the tank regularly but it appears the
alarm E26.
Check the pressure of water supply, check that the
injectors are still present in the chamber, check the
pressure regulator (it must be calibrated to 1.5 bar),
check wiring and switching of pressure switch (must
be wired to the C and NO to terminals 37 and 41 of the
power board)
13
-
During Phase 4 the water level into
the tank does
n’t flow down.
Check wiring and power supply of the drain solenoid
valve (terminal 63), check fuse F1, make sure the
drain pipe is not crushed, check that the sprinklers in
the chamber not all clogged, check the siphon of the
oven is not obstructed, replace the coil of the drain
solenoid valve (if not just replace the whole solenoid
valve).
14
-
During Phase 4 the liquid level into
the tank flow down but the float
leve
l sensor doesn’t switch.
Replace the float level sensor.
Содержание ANGELO PO BX101E
Страница 1: ...1 Rev 0...
Страница 8: ...Copyright by Servizio Clienti ANGELO PO Spa 8 OVEN CONNECTION DIAGRAM eg BX 61 G...
Страница 29: ...Copyright by Servizio Clienti ANGELO PO Spa 29...
Страница 35: ...Copyright by Servizio Clienti ANGELO PO Spa 35 Functional diagram gas system...
Страница 50: ...Copyright by Servizio Clienti ANGELO PO Spa 50 4 2 10 Heat exchanger...
Страница 62: ...Copyright by Servizio Clienti ANGELO PO Spa 62 MAGNET POSITION DURING THE COMBUSTION FUME COLLECTION...
Страница 75: ...Copyright by Servizio Clienti ANGELO PO Spa 75...
Страница 92: ...Copyright by Servizio Clienti ANGELO PO Spa 92 5 1 6 Washing consumption table...
Страница 95: ...Copyright by Servizio Clienti ANGELO PO Spa 95...