4.3.3.
GAS alarm: E12:F4: flame missing
The diagram shows an ignition cycle where there is no detection of flame. During the cycle
you have 3 ignition attempts (spark) 3 seconds long, each one preceded by purging of the
combustion chamber (necessary for removing from the combustion chamber the gas
released previously).
After these 3 attempts the combustion control board goes into state "8” the combustion is
blocked and the display shows the alarm E12:F4. The alarm can be reset by the user. The
causes may be different, for details please refer to section Gas Alarms.