![MARMON ANGELO PO BX101E Скачать руководство пользователя страница 42](http://html1.mh-extra.com/html/marmon/angelo-po-bx101e/angelo-po-bx101e_technical-manual_1730140042.webp)
Copyright by Servizio Clienti ANGELO PO Spa
42
4.2.5.
Combustion control board
NOTE
: during the installation,
it’s necessary to respect the correct connection of phase
and neutral (not inverted). If the connection is inverted the microAmpere reading of the
flame detector will be lower as it should be. To check, remember that the voltage
measured between
NEUTRAL
and
EARTH
is
0±10 Vac