MGT 2” 60M–600M NXT2 SYSTEM 14 DEMAND
OPERATION
MASTER PROGRAMMING - TWIN ALTERNATING (SYSTEM 7)
STEP
FACTORY SETTING
RANGE
SETTINGS REVIEW
OFF
On-Off
LANGUAGE
ENGLISH
English, Francais, Deutsch, Italiano, Espanol,
Nederlands, Portugues
ASSISTANCE NAME 1
ENTERED BY DEALER
ASSISTANCE NAME 2
ENTERED BY DEALER
ASSISTANCE PHONE
ENTERED BY DEALER
SYSTEM
System 14 (2-8 Units) Demand R
System 4 (Single Unit)
System 5 (2-8 Units) Parallel Interlock
System 6 (2-8 Units) Parallel Series Regeneration
System 7 (2 Units) Alternating (I)
System 8 (2 Units) Alternating (D)
System 9 (2-8 Units) Alternating with Stanby Uni
System 14 (2-8 Units) Demand Recall
NUMBER OF TANKS
2-8
2 thru 8
TRIP POINT #1 - GPM
see data table*
1-9999
TRIP POINT #1 - SERVICE
DURATION
3
1 S
1-90 seconds
TRIP POINT #1 - STANDBY
DURATION
4
60 S
60 - 300 seconds
TRIP POINT #2, #3, etc
as needed
VALVE
2900
2815, 2510, 2750, 2850, 2900, 3150, 3900
REGEN. FLOW
Downflow
Filter
Downflow
UNITS
US
US, Metric
CAPACITY - GRAINS*
see data table*
0-9,999,999 Grains
HARDNESS - GPG
ENTERED BY DEALER
0-199 gpg
REMOTE REGENERATION
Off
Off
Delayed
Immediate
DAY OVERRIDE/TIME DRIVEN 7
Off - 99 Days
REGEN. TIME
02:00AM
Any Time
LOCK WINDOW #1
Off
Off, On
LOCK WINDOW #2
Off
Off, On
BACKWASH
10 M
0-240 Mins
DRAW
60 M
0-240 Mins
RAPID RINSE
10 M
0-240 Mins
REFILL*
see data table*
0-240 Mins
PAUSE
0 M
0-240 Mins
METER TYPE*
see data table*
Generic
Paddle (0.75", 1.00", 1.50", 2.00", 3.00")
Turbine (0.75", 1.00", 1.25", 1.50")
CONTINUOUS FLOW DETECT Off
On, Off
AUXILIARY 1
Off
Standby, Off, Alarm Based, Cycle Based, Time Based,
Volume Based
AUXILIARY 2
Off
Standby, Off, Alarm Based, Cycle Based, Time Based,
Volume Based
PUSH SETTINGS
1
On
On, Off
SAVE AS NON-FACTORY
2
On
On, Off
LOCK SETTINGS
Off
Time Based, Off, Delayed, Enter Code
* For settings with an asterisk, consult the data table on page 5.
1
Use PUSH SETTINGS to push the programming settings to the other unit. You only have
to program one unit.
2
Use "SAVE AS NON-FACTORY" to save all the programmed settings. When resetting
the board, you can choose to reset to factory default settings or the non-factory settings.
3
Trip Point - Service Duration is how long the service flow is over the trip point before an additional unit is brought online.
4
Trip Point - Standby Duration is how long the service flow is under the trip point before a unit brought offline.