background image

OPERATING 
INSTRUCTIONS

1. Heater must be properly installed before operation.

2. Rotate wall thermostat knob counterclockwise until control

stops.  This is the minimum heat setting.

3. Turn power supply to heater “ON” at main switch panel.

4. Heater should not operate.  If it operates, disconnect power

and re-check wiring.

5. Rotate wall thermostat knob clockwise until it stops (maxi-

mum heat setting) and wait at least 2 minutes.  Fan control
will delay fan coming on until element is warm.

6. If heater and fan do not come on, disconnect power and

check wiring.

7. Allow heater to continue to operate until room temperature

reaches desired comfort level.  Then rotate wall thermostat
knob counterclockwise slowly until thermostat clicks off.  Fan
must continue to operate for a minute or so until element
cools.  If fan turns off immediately when thermostat is turned
off, disconnect power and check wiring.  (See Fan Delay
Notice).

8. It may be necessary to readjust thermostat a time or so until

exact comfort level is attained.  Rotation in the clockwise
direction will increase the amount of time the heater will pro-
duce heat.  Rotation in the counterclockwise direction will
reduce the amount of time the heater is on.

NOTE:  

For best results, the heater should be left “ON” constant-

ly during the heating season as the thermostat, when properly
set, will maintain the desired temperature.  In the full counter-
clockwise position the heater will remain off until the room tem-
perature drops well below freezing.

Operational Notice:

Your heater is equipped with an automatic reset over-tempera-
ture limit control that will automatically turn the heater off to pre-
vent a fire if the heater overheats. If heater cycles off on this con-
trol, a red alarm light will illuminate.

MAINTENANCE 
INSTRUCTIONS

It is important to keep this heater clean. Your heater will give you
years of service and comfort with only minimum care.  To assure
efficient operation follow the simple instructions below.

User Cleaning Instructions:

1. After the heater has cooled, a vacuum cleaner with brush

attachment may be used to remove dust and lint from exterior
surfaces of the heater including the grille openings.  

2. With a damp cloth, wipe dust and lint from grille and exterior

surfaces.

3. Return power to heater and check to make sure it is operat-

ing properly.

Maintenance Cleaning Instructions: 

(To be performed only by Qualified Service Personnel)

At least annually, the heater should be cleaned and serviced by
a qualified service person to assure safe and efficient operation.
This should include the removal of the grille and, as necessary
the heater from the backbox to clean residue from the unit.  After
completing the cleaning and servicing, the heater should be fully
reassembled and checked for proper operation. 

ALL  SERVICING  BEYOND  SIMPLE  CLEANING  THAT
REQUIRES  DISASSEMBLY  SHOULD  BE  PERFORMED  BY
QUALIFIED SERVICE PERSONNEL.

CAUTION - DO NOT CONTINUE TO ATTEMPT TO USE THE
HEATER IF THE SAFETY CONTROL REPEATEDLY OPER-
ATES AFTER BEING RESET.  TO DO SO COULD PERMA-
NENTLY DAMAGE THE HEATER OR CREATE A FIRE OR
SAFETY HAZARD.

DO  NOT  TAMPER  WITH  OR  BYPASS  ANY  SAFETY  LIMITS
INSIDE HEATER.

TO  REDUCE  RISK  OF  FIRE  AND  ELECTRIC  SHOCK  OR
INJURY,  DISCONNECT  ALL  POWER  COMING  TO  HEATER
AT MAIN SERVICE PANEL AND CHECK THAT THE ELEMENT
IS  COOL  BEFORE  SERVICING  OR  PERFORMING 
MAINTENANCE.

4

Содержание U1000FA

Страница 1: ...nly as described in this manual Any other use not recommended by the manufacturer may cause fire electric shock or injury to persons 11 This heater is provided with a red alarm light that will illumi nate only if the heater has turned off as a result of over heating If you see the light on immediately turn the heater off and inspect for any objects on or adjacent to the heater that may have blocke...

Страница 2: ...ruction 1 Carefully mark and cut a hole measuring 9 3 8 235mm wide by 11 1 8 283mm long One edge of the hole must be cut along the edge of a joist 2 Proceed to No 1 through 6 Installation of Back Box in New Construction To prevent a possible fire injury to persons or damage to the heater adhere to the following 1 Disconnect all power coming to heater at main service panel before wiring or servicin...

Страница 3: ...ect the black supply lead to the heaters black pigtail lead For 208 and 240 volt heaters change the color of the heaters white pigtail lead to black by wrapping with black electrical tape Most electri cal codes require the supply leads to be conneced to black leads Then connect the two black supply leads to the two black receptacle leads Connect the two red thermostat leads to thermostat as shown ...

Страница 4: ... ture limit control that will automatically turn the heater off to pre vent a fire if the heater overheats If heater cycles off on this con trol a red alarm light will illuminate MAINTENANCE INSTRUCTIONS It is important to keep this heater clean Your heater will give you years of service and comfort with only minimum care To assure efficient operation follow the simple instructions below User Clea...

Страница 5: ... WARRANTIES ARE IN LIEU OF ALL OTHER WARRANTIES EXPRESSED OR IMPLIED AND ALL IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE WHICH EXCEED THE AFORESAID EXPRESSED WARRANTIES ARE HEREBY DISCLAIMED AND EXCLUDED FROM THIS AGREEMENT MARLEY ENGINEERED PRODUCTS SHALL NOT BE LIABLE FOR CONSEQUENTIAL DAMAGES ARISING WITH RESPECT TO THE PRODUCT WHETHER BASED UPON NEGLIGENCE TORT S...

Страница 6: ...6 Notes Notas Notes ...

Страница 7: ... lo utilice en áreas en las que se utilice o almacene gasolina pintura o líquidos inflamables 10 Utilice este calefactor únicamente de la manera descrita en este manu al Cualquier otra forma de uso no recomendada por el fabricante puede ser causa de incendio choque eléctrico o daños personales 11 Este calefactor cuenta con una luz de alarma roja que se ilumina única mente si el calefactor se ha ap...

Страница 8: ... los bordes del agujero debe cortarse a lo largo del borde de una viga 2 Realice los pasos N 1 al 6 Instalación de la caja posterior en una construcción nueva Para evitar un posible incendio lesiones personales o daños al calefactor observe lo siguiente 1 Antes de proceder a tareas de conexionado o de reparación del calefactor desconecte toda la alimentación eléctrica que llega al mismo desde el t...

Страница 9: ...l color del conductor flexible blanco del calefactor a negro envolviéndolo en cinta eléctrica negra La mayoría de los códigos eléctricos requieren que los cables de conexión de alimentación se conecten a cables de conexión negros Luego conecte los dos cables de conexión de alimentación negros a los dos cables de conexión de tomacorriente negros Conecte los dos cables de conexión de termostato rojo...

Страница 10: ...ue la temperatura de la habitación disminuya bien por debajo del punto de congelación Aviso operacional Su calefactor está equipado con un control de límite de sobretemperatu ra con reposición automática que lo apagará automáticamente para impedir su sobrecalentamiento que podría provocar un incendio INSTRUCCIONES DE MANTENIMIENTO Es importante mantener limpio este calefactor Su calefactor le brin...

Страница 11: ...XPRESA O IMPLÍCITA Y POR LA PRESENTE SE DECLINA Y EXCLUYE DE ESTE ACUERDO TODA GARANTÍA IMPLÍCITA DE COMERCIABILIDAD Y ADECUACIÓN A UN PROPÓSITO PARTICULAR QUE EXCEDA LAS GARANTÍAS EXPRESAS ANTEDICHAS MARLEY ENGINEERED PRODUCTS NO SE HARÁ RESPONSABLE POR DAÑOS CONSIGUIENTES QUE SE PRODUZCAN CON RESPECTO AL PRODUCTO EN BASE YA SEA A NEGLIGENCIA AGRAVIO RESPONSABILIDAD ESTRICTA O CONTRATO Algunos es...

Страница 12: ...ou des étincelles électriques Ne l utilisez pas dans des zones où de l essence ou des liquides inflammables sont util isés ou entreposés 10 N utilisez ce radiateur que comme c est décrit dans ce manuel Toute autre utilisation non recommandée par le constructeur peut causer un départ d incendie une commotion électrique ou des blessures corporelles 11 Ce radiateur est fourni avec un voyant rouge d a...

Страница 13: ...u radiateur Vor la Figure 1 Positionnement du boîtier arrière dans une construction existante 1 Découpez soigneusement une ouverture de 9 3 8 235 mm de large sur 11 1 8 283 mm de long Un bord de l ouverture doit être coupé le long du côté d une solive 2 Effectuez les étapes 1 à 6 précédentes Installation de boîtier arrière dans une construction neuve Pour éviter un possible départ d incendie des b...

Страница 14: ...ateurs en 208 et 240 volts changez la couleur du fil blanc du radiateur en noir en entourant son extrémité avec de la bande adhésive noire d électricien la plupart des normes électriques exigent que les fils d alimentation soient reliés à des fils noirs Puis branchez les deux fils d alimentation noirs sur les deux fils noirs du réceptacle Branchez les deux fils rouges de thermostat au thermostat c...

Страница 15: ...otection automatique con tre un dépassement de température qui coupe automatiquement le radi ateur pour éviter un départ d incendie en cas de surchauffe INSTRUCTIONS D ENTRETIEN Il est important de garder propre le radiateur Votre radiateur vous fourni ra des années de bon service et de confort avec juste un minimum de soins Pour assurer son fonctionnement efficace suivez les instructions simples ...

Страница 16: ...CÈDENT TIENNENT LIEU DE TOUTES LES AUTRES GARANTIES EXPLICITES OU IMPLICITES ET TOUTES LES GARANTIES IMPLICITES DE VALEUR MARCHANDE ET D ADÉQUATION POUR UNE FINALITÉ SPÉCIFIQUE QUI EXCÉDERAIENT LES DISPOSITIONS DE GARANTIE PRÉCÉDEMMENT ÉNONCÉES SONT ICI REJETÉES ET EXCLUES DE CET ACCORD MARLEY ENGINEERED PRODUCTS NE SERA PAS TENU POUR RESPON SABLE DES DOMMAGES CONSÉCUTIFS SURVENANT EN RELATION AVE...

Отзывы: