background image

6

Safety Notes

•  This locomotive is to be used with the operating system 

designed for it.

•   Use only switched mode power supply units and transfor

-

mers that are designed for your local power system. 

•  This locomotive must never be supplied with powaer from 

more than one power pack.

•   Pay close attention to the safety notes in the instructions 

for your operating system.  

•  Not for children under 15 year of age. 

•  

WARNING!

 Sharp edges and points required for operation.

General Notes

•   The operating instructions are a component part of the 

product and must therefore be kept in a safe place as 

well as included with the product, if the latter is given to 

someone else. 

•   Please see your authorized LGB dealer for repairs or 

spare parts.

•   http://www.maerklin.com/en/imprint.html 

Functions

•   This model is designed for operation on LGB two-rail DC 

systems with conventional LGB DC train controllers or 

power packs (DC, 0 - 24 volts). 

•   Use a locomotive controller with more than 1 amp of train 

current for this model. 

Mode of Operation Switch  

There are two power control switches located under the 

roof of the front cab (underneath the pantograph, Fig. 1, 2). 

Use the rear switch to select track or catenary power: 

Position U:  track power 

Position O:  catenary power 

Use the front switch to select among the following functions:

Pos. 0   All power off 

Pos. 1   Power to lights 

Pos. 2   Power to motors and lights 

Pos. 3   Same as Position 2 

Catenary Power Operation 

This locomotive can be operated with a powered catenary 

system. The bottom of this model is marked with a red dot. 

Place the model on the track with the red dot pointing to 

the rail that is not connected to the catenary power supply 

(Fig. 4). 

CAUTION!

 This model may be powered with a catenary on 

analog layouts only. For operation with the digital Multi-

Train System, the model must use track power. Otherwise, 

dangerously high voltages may result. 

Multi-Purpose Socket 

The model has a “flat“ multi-purpose socket, with a remov-

able cover, on each end wall (Fig. 3). These sockets can be 

used to provide track power to cars with lighting or sound 

electronics. 

Содержание 24390

Страница 1: ...Modell der ABe 4 4 I 24390...

Страница 2: ...ll ist eine detailgetreue Nachbildung des Vor bilds in der Farbgebung und Beschriftung der 1980er Jahre The Prototype The Bernina line of the Rh tische Bahn connects St Moritz in Switzerland with Tira...

Страница 3: ...convois Le mod le r duit de LGB est une fid le reproduction du prototype dans la livr e des ann es 1980 Inhaltsverzeichnis Seite Sicherheitshinweise 4 Allgemeine Hinweise 4 Funktionen 4 Betriebshinwe...

Страница 4: ...h des vor deren F hrerstandes unter dem Pantographen Abb 1 2 die durch die T ren erreichbar sind Mit dem hinteren Schalter stellen Sie ein ob das Modell den Fahrstrom aus den Gleisen oder aus der Ober...

Страница 5: ...lampen Lampen unten Vorsichtig das Glas von der Laterne hebeln Mit einer Pinzette die eingesteckte Gl hlampe aus der Fassung ziehen Neue Gl hlampe einsetzen Modell wieder zusammenbauen Lampen oben Lam...

Страница 6: ...ler with more than 1 amp of train current for this model Mode of Operation Switch There are two power control switches located under the roof of the front cab underneath the pantograph Fig 1 2 Use the...

Страница 7: ...ights Remove the ring around the lantern lens Ca refully pry the lens away from the lantern Using tweezers remove and replace the bulb Reassemble Upper lights Pull the lantern housing away from the mo...

Страница 8: ...e utilisez un r gulateur de marche avec courant moteur sup rieur 1 A Commutateur de mode d exploitation Deux s lecteurs d alimentation sont situ s sous le toit de la cabine avant sous le pantographe I...

Страница 9: ...une goutte d huile de nettoyage LGB 50019 Remplacement des ampoules Feux inf rieurs D poser l anneau de la lentille de la lanter ne Sortir avec pr caution la lentille de la lanterne l aide de pincette...

Страница 10: ...10 3 2 1 0 O U 0 1 2 3 0 1 2 3 0 1 2 3 0 1 2 3 Abb 1 2 Betriebsartenschalter Fig 1 2 Power control switch Img 1 2 Modes d exploitation...

Страница 11: ...b 3 Mehrzweck Steckdosen Fig 3 Multi purpose sockets Img 3 S lecteur de fonctions Abb 4 Oberleitungs Betrieb Fig 4 Catenary power Img 4 Alimentation par ligne suspension cat naire Trafo 2 1 0 2 Trafo...

Страница 12: ...12 22 21 21 5 6 5 22 3 5 21 21 20 19 22 6 22 22 19 18 19 19 22 4 Details der Darstellung k nnen von dem Modell abweichen 2 23 1 1 1 1 1 23 23 23 23 23 23 23 1 1 1...

Страница 13: ...13 22 7 21 22 7 21 22 22 7 7 Details der Darstellung k nnen von dem Modell abweichen...

Страница 14: ...14 11 12 9 13 10 10 11 19 19 19 19 19 19 19 19 19 22 8 8 13 19 19 19 19 15 14 23 23 23 22 9 17 17 Details der Darstellung k nnen von dem Modell abweichen...

Страница 15: ...taktdr hte E177 051 11 Haftreifen E126 174 12 Radsatz m Einst E137 859 13 Rad mit Zahnrad auf Achse E132 024 14 Zubeh r Set Puffer Schienenr umer E177 059 15 Zubeh r Set Kupplung E171 327 16 17 Beilag...

Страница 16: ...162582 0511 Sm1Ef nderungen vorbehalten Gebr M rklin Cie GmbH Gebr M rklin Cie GmbH Stuttgarter Str 55 57 73033 G ppingen Deutschland www lgb de...

Отзывы: