4
2.0
INSTALLATION INSTRUCTIONS
(Continued)
ADJUSTMENT FOR HIGH ALTITUDE LOCATIONS
The steamer has been factory set so that when it is ON, and during the READY phase, it will
maintain water temperature in the steam generator tank at approximately 205
o
F (96
o
C) (just
below water boiling point). However, for high altitude locations, an authorized service agency
must adjust the steamer to achieve this temperature.
ADJUSTMENT FOR DRAIN WATER TEMPERATURE
Cooling solenoid valves have been adjusted to yield drain temperatures of 140
o
F. This will vary
depending on install location water supply temperature and pressure. A qualified service
person should adjust the cooling solenoid valves should the drain temperature be other than
desired. Refer to section 7.0 Adjustments on page 23 for adjustment instructions.
DRAIN CONNECTIONS
(FIGURE 2)
The drain connection (Fig. 2) must be 1" IPS down, preferably with one elbow only, maximum
length of 6 feet and piped to an open air gap type drain. Use copper only.
FIGURE 2 / Drain Connections
CAUTION: In order to avoid any back pressure in the steamer, do
not connect solidly to any drain connection.
Содержание MPS-3E
Страница 27: ...24 8 0 PARTS FIGURE 3 Exploded View ...
Страница 33: ...30 9 0 WIRING ...
Страница 34: ...31 9 0 WIRING Continued ...
Страница 35: ...32 9 0 WIRING Continued ...
Страница 36: ...33 9 0 WIRING Continued ...
Страница 37: ...34 9 0 WIRING Continued ...
Страница 38: ...35 9 0 WIRING Continued ...