5.0 PREVENTIVE MAINTENANCE (Continued)
Before beginning deliming procedures, ensure that water is not overflowing into the cooking
compartment.
WARNING: Read and follow instructions on the TOTAL CONCEPT
bottle. Use plastic or rubber gloves to avoid skin contact. If TOTAL
CONCEPT comes in contact with skin, rinse with clean water.
CAUTION: Do not open deliming caps when unit is in operation. Do
not open or close compartment doors when deliming caps are not in
place.
Should your steamer develop a heavy build-up of lime scale deposits, use the Total Concept
available from your authorized service agent.
Before beginning deliming procedures, ensure that water is not overflowing into the cooking
compartment.
GENERATOR DELIMING INSTRUCTIONS
CAUTION: Do not open or close compartment doors or operate unit
when deliming caps are not in place.
1.
Turn the power switch “OFF” for three minutes, allowing the generator to completely
empty.
2.
Turn the power switch to the “DELIME” position.
3. Remove cap located on top right of steamer. Using a funnel and pouring slowly to avoid
spilling, pour one quart (1 liter) of Market Forge’s Total Concept deliming solution into
the generator.
4.
Replace the deliming cap and tighten. Turn power switch to “ON” for five minutes
allowing the generator to completely fill.
5. Turn the
power switch to the “DELIME” position. Unscrew the deliming cap and add a ½
quart (0.5 liters) of clean water.
6.
Replace the deliming cap and tighten. Turn the power switch “ON” for 30 minutes.
7.
Flush the generators three times. Turn power switch to “OFF” for three minutes and the
“ON” for five minutes.
Содержание MPS-3E
Страница 27: ...24 8 0 PARTS FIGURE 3 Exploded View ...
Страница 33: ...30 9 0 WIRING ...
Страница 34: ...31 9 0 WIRING Continued ...
Страница 35: ...32 9 0 WIRING Continued ...
Страница 36: ...33 9 0 WIRING Continued ...
Страница 37: ...34 9 0 WIRING Continued ...
Страница 38: ...35 9 0 WIRING Continued ...